ASTM D4468-1985(2011) Standard Test Method for Total Sulfur in Gaseous Fuels by Hydrogenolysis and Rateometric Colorimetry《用还原法和比色法测定气体燃料中总硫含量的标准试验方法》.pdf
《ASTM D4468-1985(2011) Standard Test Method for Total Sulfur in Gaseous Fuels by Hydrogenolysis and Rateometric Colorimetry《用还原法和比色法测定气体燃料中总硫含量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4468-1985(2011) Standard Test Method for Total Sulfur in Gaseous Fuels by Hydrogenolysis and Rateometric Colorimetry《用还原法和比色法测定气体燃料中总硫含量的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4468 85 (Reapproved 2011)Standard Test Method forTotal Sulfur in Gaseous Fuels by Hydrogenolysis andRateometric Colorimetry1This standard is issued under the fixed designation D4468; the number immediately following the designation indicates the year oforiginal adoption or, in the case
2、 of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of sulfurgaseous fuels in the range from 0.001 to
3、20 parts per million byvolume (ppm/v).1.2 This test method may be extended to higher concentra-tion by dilution.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 This standard may involve hazardous materials, opera-tions,
4、and equipment. This standard does not purport toaddress all of the safety concerns associated with its use. It isthe responsibility of the user of this standard to establishappropriate safety and health practices and determine theapplicability of regulatory limitations prior to use. Specificprecauti
5、onary statements are given in 6.7, 6.8, and 7.3.2. Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent WaterD1914 Practice for Conversion Units and Factors Relatingto Sampling and Analysis of AtmospheresD4045 Test Method for Sulfur in Petroleum Products byHydrogenolysis and Rateo
6、metric Colorimetry3. Summary of Test Method3.1 The sample is introduced at a constant rate into aflowing hydrogen stream in a hydrogenolysis apparatus. Thesample and hydrogen are pyrolyzed at a temperature of 1000Cor above, to convert sulfur compounds to hydrogen sulfide(H2S). Readout is by the rate
7、ometric detection of the colori-metric reaction of H2S with lead acetate. Units used are ppm/v,which is equivalent to micromoles/mole.4. Significance and Use4.1 This test method can be used to determine specification,or regulatory compliance to requirements, for total sulfur ingaseous fuels. In gas
8、processing plants, sulfur can be acontaminant and must be removed before gas is introduced intogas pipelines. In petrochemical plants, sulfur is a poison formany catalysts and must be reduced to acceptable levels,usually in the range from 0.01 to 1 ppm/v. This test methodmay also be used as a qualit
9、y-control tool for sulfur determi-nation in finished products, such as propane, butane, ethane,and ethylene.5. Apparatus5.1 Pyrolysis FurnaceA furnace that can provide anadjustable temperature of 900 to 1300C in a quartz or ceramictube of 5 mm or larger tube (ID) is required for pyrolysis of thesamp
10、le. (See Fig. 1.) The flow system is to be a fluorocarbonor other material inert to H2S and other sulfur compounds. (SeeFig. 1.)5.2 Rateometric H2S ReadoutHydrogenolysis productscontain H2S in proportion to sulfur in the sample. The H2Sconcentration is determined by measuring rate of change ofreflec
11、tance of a tape impregnated with lead acetate caused bydarkening when lead sulfide is formed. Rateometric electron-ics, adapted to provide first derivative output, allows sufficientsensitivity to measure to 0.001 ppm/v. (See Fig. 2.)5.3 RecorderA suitable chart recorder may be used for apermanent re
12、cord of analysis.6. Reagents and Materials6.1 Purity of ChemicalsReagent grade unless specifiedotherwise.6.2 Purity of WaterUnless otherwise indicated, referenceto water shall be understood to mean Type II, reagent gradewater, conforming to Specification D1193.6.3 Sensing TapeLead acetate impregnate
13、d analyticalquality filter paper shall be used.1This test method is under the jurisdiction ofASTM Committee D03 on GaseousFuels and is the direct responsibility of Subcommittee D03.05 on Determination ofSpecial Constituents of Gaseous Fuels.Current edition approved Nov. 1, 2011. Published December 2
14、011. Originallyapproved in 1985. Last previous edition approved in 2006 as D446885 (2006).DOI: 10.1520/D4468-85R11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to t
15、he standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.FIG. 1 Hydrogenolysis Flow DiagramFIG. 2 Photorateometry H2S ReadoutD4468 85 (2011)26.4 Acetic Acid (5 %)Mix 1 part by volume reage
16、nt gradeglacial acetic acid with 19 parts water to prepare 5 % aceticacid solution.6.5 Gastight SyringeA gastight 0.1- and 0.5-mL syringefor preparing calibration standard. Volumetric measurementaccuracy of the syringe shall be 1 % or better.6.6 Piston CylinderUse a 10-Lacrylic cylinder with a freem
17、oving piston and silicone rubber “O” ring lubricated with afree-flowing silicone lubricant. This cylinder is used to prepareppm/v calibration samples volumetrically.6.7 Carbonyl Sulfide (COS)Alecture bottle of COS, 99 %purity, with a needle valve connected to the lecture bottleoutlet. Connect 2 ft o
18、f tygon tubing to allow insertion of ahypodermic syringe to withdraw pure COS while tubing ispurged from the lecture bottle. Other sulfur compounds can beused with adequate odor control. If the sulfur compound hastwo sulfur atoms per molecule, reduce the volume by one half.(WarningWork with COS shou
19、ld be done in a well-ventilated area, or under a fume hood.)6.8 Hydrogen GasUse sulfur-free hydrogen of laboratorygrade. (WarningHydrogen has wide explosive limits whenmixed with air. See 1.4 regarding precautions.)6.9 Carrier Gas for Calibration StandardsUse sulfur-freelaboratory grade bottled gas
20、of the same type or similar densityas the gas to be analyzed or calibrate the flowmeter to establishcorrect flow setting for an available carrier gas. Test, as in 7.5,adding the carrier gas flow to the hydrogen flow.6.10 Purge GasSulfur-free purge gas, nitrogen, CO2,orother inert gas. Commercial gra
21、de cylinder gas is satisfactory.7. Preparation of Apparatus7.1 Turn on the furnace and allow temperature to stabilize at1000C. If thiophenic sulfur could be present, use 1300Ctemperature setting.NOTE 1Reduced operating temperature extends furnace life. Thio-phenic compound conversion increases from
22、about 60 % at 1000C to100 % at 1300C.7.2 Connect all flow tubing between components and fillhumidifier inside the cabinet to 30 mL with a 5 % by volumeacetic acid solution. Purge all flow systems with inert gas thenclose valve. Check all connections for leaks with soap solutionand repair any leaks.
23、Connect hydrogen and set flow at 200mL/min and allow temperature to stabilize. Sample flow mustbe13 or less of the H2flow. Total flow can be up to 500mL/min, except when the sample has thiophenic compoundsthat require 200 mL/min of H2flow for conversion. Make finaltemperature adjustment to 1000 6 15
24、C or a minimum 1300Cif the sample contains thiophenic sulfur compounds.7.3 Install sensing tape and turn H2S readout analyzer on.Use adequate safety precautions in handling lead acetate tape.7.4 Adjust the zero of the analyzer indicator meter (andrecorder if used) to desired position with no flow. T
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD446819852011STANDARDTESTMETHODFORTOTALSULFURINGASEOUSFUELSBYHYDROGENOLYSISANDRATEOMETRICCOLORIMETRY

链接地址:http://www.mydoc123.com/p-517141.html