ASTM D4457-2002(2014) Standard Test Method for Determination of Dichloromethane and 1 1 1-Trichloroethane in Paints and Coatings by Direct Injection into a Gas Chromatograph《使用气相色谱.pdf
《ASTM D4457-2002(2014) Standard Test Method for Determination of Dichloromethane and 1 1 1-Trichloroethane in Paints and Coatings by Direct Injection into a Gas Chromatograph《使用气相色谱.pdf》由会员分享,可在线阅读,更多相关《ASTM D4457-2002(2014) Standard Test Method for Determination of Dichloromethane and 1 1 1-Trichloroethane in Paints and Coatings by Direct Injection into a Gas Chromatograph《使用气相色谱.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4457 02 (Reapproved 2014)Standard Test Method forDetermination of Dichloromethane and 1,1,1-Trichloroethanein Paints and Coatings by Direct Injection into a GasChromatograph1This standard is issued under the fixed designation D4457; the number immediately following the designation indi
2、cates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination
3、of totalamount of dichloromethane or 1,1,1-trichloroethane, or both, inpaints and coatings. It has been evaluated for cellulose nitrate,alkyd, vinyl, and styrene-butadiene systems. It has not yet beenevaluated for other formulations, but is believed to be appli-cable. The established working range o
4、f this test method isfrom 31 to 65 % for 1,1,1-trichloroethane and 32 to 78 % fordichloromethane. There is no reason to believe it will not workoutside of these ranges. The presence of 1-propanol in paintsand coatings requires the use of a different internal standard.(See also Practice E260.)1.2 The
5、 values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated
6、with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific hazardstatements are given in Section 7.2. Referenced Documents2.1 ASTM Standards:2E180 Practice
7、for Determining the Precision of ASTMMethods for Analysis and Testing of Industrial and Spe-cialty Chemicals (Withdrawn 2009)3E260 Practice for Packed Column Gas Chromatography3. Summary of Test Method3.1 Anhydrous 1-propanol (see 10.5) is added as an internalstandard to suitable aliquot of the whol
8、e paint. The aliquot isthen diluted with dimethylformamide and injected onto a gaschromatographic column containing a porous polymer packingthat separates dichloromethane and 1,1,1-trichloroethane fromother volatile compounds.4. Significance and Use4.1 Use of 1,1,1-trichloroethane and dichloromethan
9、e,which do not measurably contribute to the atmospheric oxidantlevel, is a way for industry to meet government or otherregulations on volatile organic compounds. This test method isdesigned to determine the content of these halohydrocarbonsolvents in paints and coatings. That content can subsequentl
10、ybe used in calculating the volatile organic compound content ofa coating.5. Apparatus5.1 Chromatograph, any gas-liquid chromatographic instru-ment equipped with a thermal conductivity detector andcapable of being temperature programmed (see Table 1).Optionally, a flame ionization detector may be us
11、ed if thesample is diluted so that no more than 1000 ppm each ofdichloromethane and 1,1,1-trichloroethane is present in theinjected specimen.5.2 Recorder, a recording potentiometer with a full-scaledeflection of 10 mV, a full-scale response time of 2 s or less,and a maximum noise of 60.03 % of full
12、scale.5.3 Pre-Column, 40 in. (100 mm) long by18 in. (3.2 mm)outside diameter stainless steel, packed with glass wool, fittedon the entrance end of the column to retain any nonvolatilematerials and minimize sludge buildup in the column.5.4 Column, 4 ft (1.22 m) long by18 in. (3.2 mm) outsidediameter
13、stainless steel, packed with 80/100 mesh (150 to180 m) porous polymer packing material,4or other suitablematerial.1This test method is under the jurisdiction of ASTM Committee D01 on Paintand Related Coatings, Materials, and Applications and is the direct responsibility ofSubcommittee D01.21 on Chem
14、ical Analysis of Paints and Paint Materials.Current edition approved July 1, 2014. Published July 2014. Originally approvedin 1985. Last previous edition approved in 2008 as D4457 02 (2008). DOI:10.1520/D4457-02R14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM
15、Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.4Porapak R, a registered trademark of Waters Associates, Inc.,
16、 Milford, MA, hasbeen found satisfactory for this purpose.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15.5 Liquid Charging Devices, such as microsyringes of 5-Lor 10-L capacity, cleaned with acetone or other suitablesolvent. Visual
17、ly inspect for plugs or cracks before and aftereach injection.5.6 Vials, 25-mL to minimize head space, capable of beingseptum sealed.56. Reagents and Materials6.1 Purity of ReagentsReagent grade chemicals shall beused in all tests, unless otherwise specified (as in 6.7). Unlessotherwise indicated, i
18、t is intended that all reagents shallconform to the specifications of the Committee on AnalyticalReagents of the American Chemical Society, where suchspecifications are available.6Other grades may be used pro-vided it is first ascertained that the reagent is of sufficient highpurity to permit its us
19、e without lessening the accuracy of thedetermination.6.2 Carrier Gas, helium of 99.995 % or higher purity. Highpurity nitrogen may also be used.6.3 Dimethylformamide (DMF), reagent grade.6.4 1-Propanol, gas chromatography spectrophotometricquality (see 10.5).6.5 1,1,1-Trichloroethane (see 6.7).6.6 D
20、ichloromethane (see 6.7).6.7 Halogenated Hydrocarbon StabilizersAll commercialgrades of these halogenated hydrocarbons contain stabilizers.Either obtain the same solvent used in the coating for use as thestandard, or find the type and quantity of stabilizer specified foruse in the solvent of interes
21、t and add the appropriate quantityto the pure solvent.7. Hazards7.1 Dimethylformamide is harmful if inhaled or absorbedthrough skin. Use only with adequate ventilation. Avoidcontact with skin, eyes, and clothing.8. Preparation of Apparatus8.1 Column ConditioningThe packed column is installedin the g
22、as chromatographic unit leaving the exit end discon-nected from the detector. This will prevent any contaminationof the detector with the column bleed. Set the helium flow rateat 30 mL/min if a18 in. (3.2 mm) outside diameter column isused. Purge the column 5 to 10 min before heating. Heat thecolumn
23、 from room temperature to 200C at 5C/min and holdthis temperature for at least 12 h (overnight). At the end of thisperiod of time, heat the column to 240C at a 5C/min rate andhold this temperature for several hours. The maximum tem-perature for this packing is 250C. Cool the column to 100Cand reheat
24、 to 240C at 5C/min to observe the column bleed.Optimum conditioning of this column may take several cyclesof the heating program before a good recorder baseline isachieved. Conditioning of any column other than that sug-gested (5.4) should be in accordance with the manufacturersrecommendations.8.2 I
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD445720022014STANDARDTESTMETHODFORDETERMINATIONOFDICHLOROMETHANEAND111TRICHLOROETHANEINPAINTSANDCOATINGSBYDIRECTINJECTIONINTOAGASCHROMATOGRAPH

链接地址:http://www.mydoc123.com/p-517117.html