ASTM D4417-2003 Standard Test Methods for Field Measurement of Surface Profile of Blast Cleaned Steel《喷砂清理钢表面轮廓现场测量的标准试验方法》.pdf
《ASTM D4417-2003 Standard Test Methods for Field Measurement of Surface Profile of Blast Cleaned Steel《喷砂清理钢表面轮廓现场测量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4417-2003 Standard Test Methods for Field Measurement of Surface Profile of Blast Cleaned Steel《喷砂清理钢表面轮廓现场测量的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 4417 03Standard Test Methods forField Measurement of Surface Profile of Blast CleanedSteel1This standard is issued under the fixed designation D 4417; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 These test methods cover the description
3、of techniquesfor measuring the profile of abrasive blast cleaned surfaces inthe laboratory, field, or in the fabricating shop. There areadditional techniques suitable for laboratory use not covered bythese test methods.1.2 The values stated in SI units are to be regarded as thestandard. The values g
4、iven in parentheses are for informationonly.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of whoever uses this standard to consult andestablish appropriate safety and health practices and deter-mine the applicability
5、 of regulatory limitations prior to use.2. Summary of Test Method2.1 The methods are:2.1.1 Method AThe blasted surface is visually comparedto standards prepared with various surface profile depths andthe range determined.2.1.2 Method BThe depth of profile is measured using afine pointed probe at a n
6、umber of locations and the arithmeticmean determined.2.1.3 Method CAcomposite plastic tape is impressed intothe blast cleaned surface forming a reverse image of the profile,and the maximum peak to valley distance measured with amicrometer.3. Significance and Use3.1 The height of surface profile has
7、been shown to be afactor in the performance of various coatings applied to steel.For this reason, surface profile should be measured prior tocoating application to ensure that it meets that specified. Theinstruments described are readily portable and sufficientlysturdy for use in the field.NOTE 1Opt
8、ical microscope methods serve as a referee method forsurface profile measurement. Profile depth designations are based on theconcept of mean maximum profile ( h max); this value is determined byaveraging a given number (usually 20) of the highest peak to lowest valleymeasurements made in the field o
9、f view of a standard measuringmicroscope. This is done because of evidence that coatings performancein any one small area is primarily influenced by the highest surfacefeatures in that area and not by the average roughness.24. Apparatus4.1 Method AAprofile comparator consisting of a numberof areas (
10、each approximately one square inch in size), usuallyside by side, with a different profile or anchor pattern depth.Each area is marked giving the nominal profile depth in mils ormicrometres. Typical comparator surfaces are prepared withsteel shot, steel grit, or sand or other nonmetallic abrasive,si
11、nce the appearance of the profile created by these abrasivesmay differ. The comparator areas are used with or withoutmagnification of 5 to 10 power.4.2 Method BA dial gage3depth micrometer fitted with apointed probe. The probe is machined at a 60 angle with anominal radius of 50 m. The base of the i
12、nstrument rests onthe tops of the peaks of the surface profile while the springloaded tip projects into the valleys.4.3 Method CA special tape4containing a compressiblefoam attached to a noncompressible uniform plastic film. Aburnishing tool is used to impress the foam face of the tape intothe surfa
13、ce to create a reverse replica of the profile that ismeasured using a spring-loaded micrometer.1These test methods are under the jurisdiction of ASTM Committee D01 onPaint and Related Coatings, Materials, and Applications and are the directresponsibility of Subcommittee D01.46 on Industrial Protecti
14、ve Coatings.Current edition approved May 10, 2003. Published June 2003. Originallyapproved in 1984. Last previous edition approved in 1999 as D 4417 93 (1999).2John D. Keane, Joseph A. Bruno, Jr., Raymond E. F. Weaver, “Surface Profilefor Anti-Corrosion Paints,” Oct. 25, 1976, Steel Structures Paint
15、ing Council, 4400Fifth Ave., Pittsburgh, PA 15213.3The sole source of supply of suitable depth micrometers known to thecommittee at this time is the surface profile gage, Model 123, Elcometer Instru-ments, Ltd., Edge Lane, Droylston, Manchester M35 6UB, United Kingdom,England. If you are aware of al
16、ternative suppliers, please proved this information toASTM International Headquarters. Your comments will receive careful consider-ation at a meeting of the responsible technical committee,1which you may attend.4The sole source of supply of suitable replica tape, Press-O-Film, known to thecommittee
17、at this time is Testex. 8 Fox Lane, Newark, DE 19711. If you are awareof alternative suppliers, please proved this information to ASTM InternationalHeadquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee,1which you may attend1Copyright ASTM I
18、nternational, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5. Test Specimens5.1 Use any metal surface that, after blast cleaning, is free ofloose surface interference material, dirt, dust, and abrasiveresidue.6. Procedure6.1 Method A:6.1.1 Select the comparator
19、 standard appropriate for theabrasive used for blast cleaning.6.1.2 Place the comparator standard directly on the surfaceto be measured and compare the roughness of the preparedsurface with the roughness on the comparator segments. Thiscan be done with the unaided eye, under 5 to 10 powermagnificati
20、on, or by touch. When using magnification, themagnifier should be brought into intimate contact with thestandard, and the depth of focus must be sufficient for thestandard and surface to be in focus simultaneously.6.1.3 Select the comparator segment that most closelyapproximates the roughness of the
21、 surface being evaluated or,if necessary, the two segments to which it is intermediate.6.1.4 Evaluate the roughness at a sufficient number oflocations to characterize the surface as specified or agreed uponbetween the interested parties. Report the range of results fromall locations as the surface p
22、rofile.6.2 Method B:6.2.1 Prior to use set the gage to zero by placing it on a pieceof plate float glass. Hold the gage by its base and press firmlyagainst the glass. Adjust the instrument to zero.6.2.2 To take readings, hold the gage firmly against theprepared substrate. Do not drag the instrument
23、across thesurface between readings, or the spring-loaded tip may becomerounded leading to false readings.6.2.3 Measure the profile at a sufficient number of locationsto characterize the surface, as specified or agreed upon betweenthe interested parties. At each location make ten readings anddetermin
24、e the mean. Then determine the mean for all thelocations and report it as the profile of the surface.6.3 Method C:6.3.1 Select the correct tape range for the profile to bemeasured: coarse, 0 to 50 m (0 to 2 mils) and extra coarse, 40to 115 m (1.5 to 4.5 mils).6.3.2 Remove the wax paper backing and p
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD44172003STANDARDTESTMETHODSFORFIELDMEASUREMENTOFSURFACEPROFILEOFBLASTCLEANEDSTEEL 喷砂 清理 表面 轮廓 现场

链接地址:http://www.mydoc123.com/p-517001.html