ASTM D4409-1995(2008) Standard Test Method for Velocity Measurements of Water in Open Channels with Rotating Element Current Meters《用旋转体流速计测量明渠中水的流速的标准试验方法》.pdf
《ASTM D4409-1995(2008) Standard Test Method for Velocity Measurements of Water in Open Channels with Rotating Element Current Meters《用旋转体流速计测量明渠中水的流速的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4409-1995(2008) Standard Test Method for Velocity Measurements of Water in Open Channels with Rotating Element Current Meters《用旋转体流速计测量明渠中水的流速的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 4409 95 (Reapproved 2008)Standard Test Method forVelocity Measurements of Water in Open Channels withRotating Element Current Meters1This standard is issued under the fixed designation D 4409; the number immediately following the designation indicates the year oforiginal adoption or,
2、in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method describes the design and use ofcup-type or vane-type vertical ax
3、is current meters andpropeller-type horizontal axis current meters for measuringwater velocities in open channels.1.2 This test method is intended primarily for those meterscustomarily used in open-channel hydraulic (as distinguishedfrom oceanographic) applications with an operator in atten-dance.1.
4、3 This test method is intended primarily for current metersthat measure one component or filament of flow.1.4 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not
5、 considered standard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior t
6、o use.2. Referenced Documents2.1 ASTM Standards:2D 1129 Terminology Relating to WaterD 2777 Practice for Determination of Precision and Bias ofApplicable Test Methods of Committee D19 on WaterD 3858 Test Method for Open-Channel Flow Measurementof Water by Velocity-Area Method2.2 ISO Standards:3ISO 2
7、537 Liquid Flow Measurement in Open ChannelsRotating Element Current MetersISO 3454 Liquid Flow Measurement in Open ChannelsDirect Depth Sounding and Suspension EquipmentISO 3455 Liquid Flow Measurement in Open ChannelsCalibration of Rotating-Element Current Meters inStraight Open Tanks3. Terminolog
8、y3.1 Definitions: For definitions of other terms used in thistest method, refer to Terminology D 1129.3.2 Definitions of Terms Specific to This Standard:3.2.1 current meteran instrument used to measure thespeed or velocity of flowing water at a point.3.2.2 Price-type current metersgeneric name for s
9、pecificvertical axis meters with a rotating element consisting of sixconical cups and constructed as described in Refs (1-3).43.2.3 spin test a test performed to check the bearings of acurrent meter. This test is used primarily with vertical axiscurrent meters.3.2.4 turbulenceirregular condition of
10、flow in which thevelocity exhibits a random variation with time and spacecoordinates so that statistically distinct average values can bediscerned.4. Summary of Test Method4.1 The angular velocity of the rotating element is afunction of water speed at the point of immersion. This angularvelocity is
11、determined from the meter output and its functionalrelation to the water speed is determined by calibration.5. Significance and Use5.1 This test method describes the design and use of varioustypes of current meters. These current meters are commonlyused to measure the velocity at a point in an open
12、channel crosssection as part of a velocity-area traverse to determine the1This test method is under the jurisdiction of ASTM Committee D19 on Waterand is the direct responsibility of Subcommittee D19.07 on Sediments, Geomor-phology, and Open-Channel Flow.Current edition approved Oct. 1, 2008. Publis
13、hed November 2008. Originallyapproved in 1984. Last previous edition approved in 2003 as D 4409 95 (2003).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standa
14、rds Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.4The boldface numbers refer to the list of references at the end of this testmethod.1Copyright ASTM International, 100 Barr Harb
15、or Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.flowrate of water. To this end it should be used in conjunctionwith Test Method D 3858.6. Interferences6.1 As with any intrusive flow measuring device, rotatingelement current meters are subject to damage by debris,especially in
16、high velocity flows, and to fouling by floatingmaterials such as aquatic growths and sewage.6.2 Owing to bearing friction, each rotating element currentmeter has a limiting low velocity below which it does notfunction reliably. This velocity is different for each type ofmeter but, in general, % erro
17、rs tend to become large as thevelocities decrease below 0.1 to 0.2 ft/s (0.03 to 0.06 m/s).7. Apparatus7.1 Current Meters Rotating element current meters con-sist of a rotating element with shaft and bearings, a mechanismfor detecting and registering revolutions, and a frame whichsupports the forego
18、ing elements and provides for suspension ofthe meter and the insertion of stabilizing fins if needed. Currentmeters covered by this test method do not customarily incor-porate direction-measuring devices.7.1.1 Rotor ConfigurationHorizontal-axis meters havepropeller-type rotors comprised of two or mo
19、re blades. Inter-changeable elements of different pitch or diameter can be usedto cover a wider range of velocities. Vertical-axis meters havea rotating wheel made up of several cup-type or vane-typeelements. Rotors employing six conical cups (for example,Price-type meters) are frequently used but o
20、ther configurationsare permissible provided the following requirements are met:7.1.1.1 The relation between velocity and rotation rate mustbe stable, that is, there should be no significant uncertainties inthe meters rating curve due to unstable flow separations at thecups or similar hydrodynamic ca
21、uses.7.1.1.2 If fractions of revolutions are to be registered, theangular movement of the rotor must be the same during eachmeasured fraction.7.1.2 Bearings:7.1.2.1 Bearing design shall permit the meter to be used insediment-laden water, without affecting the accuracy of themeter.7.1.2.2 If a partic
22、ular oil is required for bearing lubrication,the supplier shall furnish it with the instrument. Information forobtaining replacement oil shall also be furnished.7.1.2.3 At the highest velocity claimed for the meter,properly maintained bearings shall function without adverselyaffecting meter performa
23、nce for a period of time customarilyassociated with normal use or for the period of time betweenrecommended recalibrations. If bearing replacement is neededto meet this requirement, such replacement shall be possible inthe field.7.1.2.4 At the lowest velocity claimed for the meter, prop-erly maintai
24、ned bearings shall function consistently and notcontribute to undue deviations in meter response.7.1.2.5 No breaking-in period for the bearings shall berequired after meter delivery.7.1.3 Registering RevolutionsThe current meter shall beequipped with a mechanism which detects and signals eithersingl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD440919952008STANDARDTESTMETHODFORVELOCITYMEASUREMENTSOFWATERINOPENCHANNELSWITHROTATINGELEMENTCURRENTMETERS

链接地址:http://www.mydoc123.com/p-516983.html