ASTM D4337-1989(2009) Standard Test Methods for Analysis of Linear Detergent Alkylates《直链洗涤剂烷基化物分析的标准试验方法》.pdf
《ASTM D4337-1989(2009) Standard Test Methods for Analysis of Linear Detergent Alkylates《直链洗涤剂烷基化物分析的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4337-1989(2009) Standard Test Methods for Analysis of Linear Detergent Alkylates《直链洗涤剂烷基化物分析的标准试验方法》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4337 89 (Reapproved 2009)Standard Test Methods forAnalysis of Linear Detergent Alkylates1This standard is issued under the fixed designation D4337; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revi
2、sion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover chemical and physical testsapplicable to linear detergent alkylates, evaluating those prop-erties whic
3、h characterize linear detergent alkylates with respectto its suitability for desired uses.NOTE 1Linear detergent alkylates comprises linear alkylbenzenesprepared by varying processes of varying linear alkyl chain length. Thealkylate is sulfonated for surfactant use, the largest application being ind
4、etergent products. Careful control of linear detergent alkylate character-istics is desired; during sulfonation, variations of the sulfonate can occurthat may result in either desirable or undesirable end-use properties.1.2 The test methods appear as follows:SectionComposition by Gas Chromatography
5、7-15Chlorides 16-27Color 28-30Refractive Index 31-33Specific Gravity 34-36Water 37-391.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices an
6、d determine the applica-bility of regulatory limitations prior to use. Material SafetyData Sheets are available for reagents and materials. Reviewthem for hazards prior to usage. See also Note 1 and Section21.2. Referenced Documents2.1 ASTM Standards:2D270 Methods of Sampling Petroleum and Petroleum
7、 Prod-ucts3D1122 Test Method for Density or Relative Density ofEngine Coolant Concentrates and Engine Coolants By TheHydrometerD1193 Specification for Reagent WaterD1209 Test Method for Color of Clear Liquids (Platinum-Cobalt Scale)D1218 Test Method for Refractive Index and RefractiveDispersion of H
8、ydrocarbon LiquidsD1364 Test Method for Water in Volatile Solvents (KarlFischer Reagent Titration Method)E180 Practice for Determining the Precision of ASTMMethods for Analysis and Testing of Industrial and Spe-cialty Chemicals33. Significance and Use3.1 These test methods are suitable for setting s
9、pecificationson linear detergent alkylates and for quality control wherethese alkylates are manufactured or are used in a manufactur-ing process.3.2 The gas chromatography test is useful in identifyinglinear detergent alkylates produced by the various manufactur-ing processes and for determining the
10、 applicability of a lineardetergent alkylate to a particular end use. Test conditions havebeen optimized for resolution of the C-9 to C-15 lineardetergent alkylates and the presence of higher or lower chainlengths will be readily apparent but may produce erroneousresults. The tetralin structures hav
11、e not been sufficientlyidentified to allow determination of tetralins, and small uni-dentified components are reported as tetralins and unidenti-fieds.3.3 Some linear detergent alkylates use a manufacturingprocess with an organic chloride as a precursor. This test maybe used to ensure that the chlor
12、ide content of the alkylate is notexcessive for a particular end use.3.4 The platinum-cobalt color test is useful in determiningthat the color of the linear detergent alkylate will not contributeto the color of the end use product.3.5 The refractive index and specific gravity tests arepossible aids
13、in the identification of linear detergent alkylatesand in evaluating alkylates for gross contaminants.1These test methods are under the jurisdiction of ASTM Committee D12 onSoaps and Other Detergents and are the direct responsibility of SubcommitteeD12.12 on Analysis and Specifications of Soaps, Syn
14、thetics, Detergents and theirComponents.Current edition approved Oct. 1, 2009. Published March 2010. Originallyapproved in 1984. Last previous edition approved in 2003 as D4337 89(2003).DOI: 10.1520/D4337-89R09.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Cust
15、omer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn. The last approved version of this historical standard is referencedon www.astm.org.1Copyright ASTM International, 100 Barr Harbor Drive, P
16、O Box C700, West Conshohocken, PA 19428-2959, United States.3.6 The water test is suitable for determining that lineardetergent alkylates do not contain amounts of water deleteriousto further processing.4. Purity of Reagents4.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unl
17、ess otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee onAnalytical Reagents of theAmerican Chemical Society,4where such specifications are available. Other grades may beused, provided it is first ascertained that the reagent is ofsufficiently
18、high purity to permit its use without lessening theaccuracy of the determination.4.2 Unless otherwise indicated, references to water shall beunderstood to mean Type III water conforming to SpecificationD1193.5. Precautions5.1 Consult the latest OSHA regulations regarding all re-agents and materials
19、used in these test methods.56. Sampling6.1 Unless otherwise indicated in a specific test method,sample the material in accordance with Method D270, withspecial application of Sections 41 and 42 pertaining to indus-trial aromatic hydrocarbons, Section 12 pertaining to Bottle orBeaker Sampling, and Se
20、ction 15 pertaining to Tap Sampling.Samples must be taken and stored in amber, screw-cap, glassbottles to protect them from light.COMPOSITION BY GAS CHROMATOGRAPHY7. Scope7.1 The gas chromatography test was developed to allowdetermination of C-9 through C-15 linear detergent alkylateisomer distribut
21、ion before sulfonation. The analyses of stockshaving a chain length distribution above or below the intervalcovered in this test method will require a different set ofoperating conditions. If water, extremely high boiling compo-nents, or unusual impurities are present in the linear detergentalkylate
22、, this test would not necessarily detect them and mayproduce erroneous results.8. Summary of Test Method8.1 A sample is injected by means of a microsyringe into avaporization chamber of a gas chromatograph.Astream splitterallows the majority of the sample to be vented into theatmosphere through a va
23、lve that is incorporated in the vapor-ization chamber.Asmall portion of the sample is then swept bythe carrier gas into a capillary column that has been coated witha thin layer of the stationary phase. A hydrogen flame ioniza-tion detector provides a very sensitive means of detecting theextremely sm
24、all concentrations of separated vapor componentsas they elute from the column. An electrometer-amplifierconverts the detector signal into a suitable signal that can berecorded on a standard strip-chart recorder and integrated by asuitable integration device. The concentrations of the compo-nents are
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD433719892009STANDARDTESTMETHODSFORANALYSISOFLINEARDETERGENTALKYLATES 直链 洗涤剂 烷基化 分析 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-516858.html