1、Designation: D4333/D4333M 05 (Reapproved 2010)1Standard Test Method for theCompatibility of Mechanical Pump Dispenser Components1This standard is issued under the fixed designation D4333/D4333M; the number immediately following the designation indicates theyear of original adoption or, in the case o
2、f revision, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEUnits information was corrected editorially in March 2011.1. Scope1.1 This test method covers testing
3、 of the components ofmechanical pump dispensers (spray or flow types) for compat-ibility with products.1.2 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be u
4、sed independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.1.3 This standard may involve hazardous materials, opera-tions, and equipment. This standard does not purport toaddress all of the safety concerns, if any, associated with itsuse. It i
5、s the responsibility of the user of this standard toconsult and establish appropriate safety and health practicesand determine the applicability of regulatory limitations priorto use.2. Significance and Use2.1 This test method identifies the compatibility of themechanical pump dispenser components w
6、ith consumer-typeproducts.3. Apparatus3.1 Balance, accurate to 1 mg.3.2 Micrometers, or calipers or other appropriate instru-ments, capable of measuring dimensions of test specimens to0.025 mm 0.001 in.3.3 Glass Containers, with covers, suitable for immersingtest specimens in test products.3.4 Oven,
7、 with chamber capable of maintaining temperaturewithin 62C 63.6F of the specified test temperatures.4. Test Specimen4.1 At least three individual components should be used foreach part tested with each product involved at each testcondition.4.2 At least three individual components are used as con-tr
8、ols at each test condition.4.3 Individual unassembled components shall be clean andpreviously unused.5. Conditioning5.1 Condition test specimens at 23 6 3C 73.46 5.4F forat least 4 h prior to testing. If test specimen conditioning is notpossible, the environmental conditioning of the test specimenst
9、ested should be included in the report as discussed in 7.1.5.2 Test conditions shall be an elevated temperature of 45 63C 113 6 5.4F and an ambient room temperature of 23 63C 73.4 6 5.4F. If a different temperature is used, thisshould be noted in the test report discussed in 7.1.6. Procedure6.1 Dime
10、nsional and Weight Changes:6.1.1 Prior to immersion into the product, weigh the partand record as W1 (see 7). Measure the thickness or overalllength of the part to the nearest 0.025 mm 0.001 in. of eachcomponent depending on which of these dimensions are mostimportant (for example, thickness for a g
11、asket or liner, andoverall length for a molded component). Optionally, measure adiameter of the part to its nearest 0.025 mm 0.001 in. Reportthe data as initial dimension D1 (see 7). This data is reportedas a mean value of the dimension for the components measuredfor that particular part.6.1.2 Maint
12、ain at least three test specimens as visual com-parison controls. Do not immerse these control test specimensin any solution and store at each test condition. Label thestorage container of these test specimens as control.6.1.3 Place the test specimens in appropriate containers forthe solutions being
13、 used and allow the test specimens to betotally immersed in fresh test product for 7 days in each testcondition. Several test specimens of a given material may be1This test method is under the jurisdiction of ASTM Committee D10 onPackaging and is the direct responsibility of Subcommittee D10.33 on M
14、echanicalDispensers.Current edition approved Oct. 1, 2010. Published March 2011. Originallyapproved in 1984. Last previous edition approved in 2005 as D4333 05. DOI:10.1520/D4333_D4333M-05R10E01.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, Unit
15、ed States.immersed in the same container provided sufficient product isavailable for the total surface area exposed. Cover the con-tainer.NOTE 1When the components being tested are of the same type but ofdifferent material, it is recommended that separate glass containers areused for each material f
16、or the purpose of eliminating unplanned materialinteractions and for ease of identification.6.1.4 After 7 days, remove all glass containers of testspecimens from the 45C environment, and allow the testspecimens to equilibrate to room temperature 23C for aminimum of 4 h.6.1.5 Carefully remove each te
17、st specimen from the glasscontainer, wipe dry, and remeasure the dimension(s) on eachpart as they were measured in 6.1.1. Be careful not to damageor distort the parts during removal. Measure parts immediately.Report the mean value of the dimensions measured at this timeas D2 (see 7.1).6.1.6 Weigh th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD4333D4333M20052010E1TESTMETHODFORTHECOMPATIBILITYOFMECHANICALPUMPDISPENSERCOMPONENTS 机械 分配器 适应性
链接地址:http://www.mydoc123.com/p-516845.html