《ASTM D4275-2017 Standard Test Method for Determination of Butylated Hydroxy Toluene (BHT) in Polymers of Ethylene and Ethylene&x2013 Vinyl Acetate (EVA) Copolymers by Gas Chromatog.pdf》由会员分享,可在线阅读,更多相关《ASTM D4275-2017 Standard Test Method for Determination of Butylated Hydroxy Toluene (BHT) in Polymers of Ethylene and Ethylene&x2013 Vinyl Acetate (EVA) Copolymers by Gas Chromatog.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4275 09D4275 17Standard Test Method forDetermination of Butylated Hydroxy Toluene (BHT) inPolymers of Ethylene and EthyleneVinyl Acetate (EVA)Copolymers Byby Gas Chromatography1This standard is issued under the fixed designation D4275; the number immediately following the designation i
2、ndicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope Scope*1.1 This test method describes a pro
3、cedure for the determination of butylated hydroxy toluene (BHT) (2,6-di-t-butyl-4-methyl-hydroxybenzene) in polymers of ethylene and ethylene-vinyl acetate (EVA) copolymers by solvent extraction followedby gas chromatographic analysis. Detection of the compound is achieved by flame ionization, and q
4、uantitative analysis is obtainedby use of internal or external standards, as described in Practices E260, E355, and E594.1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.1.3 This standard does not purport to address all of
5、 the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use. Specific precautionary statements are given in Section 9.NOTE 1There
6、 is no known ISO equivalent for this test method.2. Referenced Documents2.1 ASTM Standards:2D883 Terminology Relating to PlasticsD4968 Practice for Annual Review of Test Methods and Specifications for PlasticsD7210 Practice for Extraction of Additives in Polyolefin PlasticsE260 Practice for Packed C
7、olumn Gas ChromatographyE355 Practice for Gas Chromatography Terms and RelationshipsE594 Practice for Testing Flame Ionization Detectors Used in Gas or Supercritical Fluid ChromatographyE691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test MethodIEEE/ASTM SI-10 P
8、ractice for Use of the International System of Units (SI) (the Modernized Metric System)3. Terminology3.1 DefinitionsUnits and symbols used in this test method are those recommended in Practice IEEE/ASTM SI-10.Chromatographic terms and relationships are as described in Practice E355.3.2 Abbreviation
9、s:3.2.1 BHTButylated hydroxy toluene (2,6-di-tert-butyl-4-methyl-hydroxybenzene).3.2.2 MMMethyl myristate.3.2.3 EVAEthylene-vinyl acetate copolymers.3.2.4 LDPELow-density polyethylene.3.2.5 HDPEHigh-density polyethylene.4. Summary of Test Method4.1 The BHT from a finely ground polymer sample is extr
10、acted by shaking or refluxing with cyclohexane or isopropanol. Aknown volume of this extract is injected into a gas chromatographic column packed with a liquid-coated solid support. Passing1 This test method is under the jurisdiction of ASTM Committee D20 on Plastics and is the direct responsibility
11、 of Subcommittee D20.70 on Analytical Methods.Current edition approved Aug. 1, 2009March 1, 2017. Published August 2009March 2017. Originally approved in 1983. Last previous edition approved in 20022009 asD4275 - 02.D4275 - 09. DOI: 10.1520/D4275-09.10.1520/D4275-17.2 For referencedASTM standards, v
12、isit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM stan
13、dard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by AST
14、M is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1through this column in a stream of carrier gas, BHT is separated from the ext
15、raction solvent and other components. Responses ofBHT and any internal standard are measured by a flame ionization detector. This signal is recorded to indicate the relativeconcentration and retention time of BHT.5. Significance and Use5.1 Separation and identification of stabilizers used in the man
16、ufacture of polyethylene are necessary in order to correlateperformance properties with polymer composition.5.2 The BHT extraction procedure is made effective by the insolubility of the polymer sample in solvents generally used forgas chromatographic analysis.6. Interferences6.1 Any material eluting
17、 at or near the BHT or MM retention times will cause erroneous results. Prior to extraction, solventblanks shall be analyzed to confirm the absence of interfering peaks.7. Apparatus7.1 Reflux Extraction, consisting of 250-mL round-bottom flask with condenser and heating mantle to fit.7.2 Wiley Mill,
18、 with 10 and 20-mesh screens.7.3 Wrist-Action Shaker.7.4 Gas Chromatograph, equipped with a flame ionization detector.7.5 Chromatographic Column, 3.2-mm outside diameter times 1.8 m packed with 20 % UCW-98 on 80/100 mesh ChromosorbP, a similar packed column, or an equivalent capillary column, such a
19、s a HP-1 or DB-1.7.6 Integrator, capable of measuring the net peak area on the back side of a solvent peak.7.7 Gas Chromatographic Syringe, 10 L.7.8 Analytical Balance, capable of weighing to 60.0001 g.7.9 Pressure Regulators, for all required gas cylinders.7.10 Filter-Dried Assemblies, for each req
20、uired gas cylinder.7.11 Soap Film Flowmeter and Stopwatch, or other means of measuring gas flow rates.8. Reagents and Materials8.1 Cyclohexane, reagent grade.8.2 Isopropyl Alcohol, reagent grade.8.3 Methyl Myristate,399+ %, boiling point 323C (internal standard).8.4 Butylated Hydroxy Toluene, food g
21、rade (2,6-di-tert-butyl-4-methyl-hydroxybenzene).8.5 Hydrogen Cylinder, prepurified.8.6 Nitrogen Cylinder, prepurified, oxygen-free for carrier gas.NOTE 2Helium or hydrogen may also be used as the carrier gas.8.7 Air, breathing or water-pumped.9. Safety Precautions9.1 Cyclohexane and isopropyl alcoh
22、ol are flammable. This extraction procedure shouldshall be carried out in a fume hood.10. Preparation of Gas Chromatograph10.1 Install the chromatographic column and condition overnight at 200C with carrier gas flow rate of 35 mL/min. Do notconnect the exit end of the column to the detector during t
23、his conditioning period. Turn off hydrogen and air flows to the detectorwhile the column is disconnected.10.2 Connect the exit end of the column to the detector. Set optimum hydrogen and air flow rates for the detector as specifiedfor the chromatograph model in use, or as determined experimentally.3
24、 The sole source of supply of the methyl myristate known to the committee at this time is Aldrich Chemical Co., P.O. Box 355, Milwaukee, WI 53201. If you are awareof alternative suppliers, please provide this information toASTM International Headquarters.Your comments will receive careful considerat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD42752017STANDARDTESTMETHODFORDETERMINATIONOFBUTYLATEDHYDROXYTOLUENEBHTINPOLYMERSOFETHYLENEANDETHYLENEX2013VINYLACETATEEVACOPOLYMERSBYGASCHROMATOGPDF

链接地址:http://www.mydoc123.com/p-516687.html