《ASTM D4230-2002e1 Standard Test Method of Measuring Humidity with Cooled-Surface Condensation (Dew-Point) Hygrometer《用冷却表面冷凝(露点)湿度计测量湿度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4230-2002e1 Standard Test Method of Measuring Humidity with Cooled-Surface Condensation (Dew-Point) Hygrometer《用冷却表面冷凝(露点)湿度计测量湿度的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 4230 02e1Standard Test Method ofMeasuring Humidity with Cooled-Surface Condensation(Dew-Point) Hygrometer1This standard is issued under the fixed designation D 4230; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, th
2、e year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.e1NOTEEditorial corrections were made throughout the test method in July 2003.1. Scope1.1 This test method covers the d
3、etermination of the ther-modynamic dew- or frost-point temperature of ambient air bythe condensation of water vapor on a cooled surface. Forbrevity this is referred to in this method as the condensationtemperature.1.2 This test method is applicable for the range of conden-sation temperatures from 60
4、C to 70C.1.3 This test method includes a general description of theinstrumentation and operational procedures, including siteselection, to be used for obtaining the measurements and adescription of the procedures to be used for calculating theresults.1.4 This test method is applicable for the contin
5、uous mea-surement of ambient humidity in the natural atmosphere on astationary platform.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices
6、 and determine the applica-bility of regulatory limitations prior to use. For specificprecautionary statements, see Section 8.2. Referenced Documents2.1 ASTM Standards:2D 1356 Terminology Relating to Sampling and Analysis ofAtmospheresD 3631 Test Methods for Measuring Surface AtmosphericPressure3. T
7、erminology3.1 Definitions:3.1.1 For definitions of other terms in this method, refer toTerminology D 1356.3.2 Definitions of Terms Specific to This Standard:3.2.1 nonhygroscopic materialmaterial that neither ab-sorbs nor retains water vapor.3.2.2 mirror (front surface)a polished surface, usually ame
8、tallic surface, on which condensates are deposited.3.3 Symbols:e = vapor pressure of water vapor in moist air.ei= saturation pressure of water vapor in equilibriumwith the plane surface of ice.ew= saturation pressure of water vapor in equilibriumwith the plane surface of water.P = ambient pressure.r
9、 = mixing ratio.T = ambient air temperature.Td= thermodynamic dew- or frost-point temperature.RHi= relative humidity with respect to ice.RHw= relative humidity with respect to water.4. Summary of Test Method4.1 The ambient humidity is measured with a dew- andfrost-point hygrometer.4.2 The mirror or
10、some other surface on which the conden-sate is deposited is provided with the means for cooling andheating, detection of condensate, and the measurement of thetemperature of the mirror surface.4.3 Calculations of saturation vapor pressure over water andice as functions of temperature are provided.5.
11、 Significance and Use5.1 Humidity information is important for the understandingof atmospheric phenomena and industrial processes. Measure-ments of the dew-point and calculations of related vaporpressures are important to quantify the humidity information.1This test method is under the jurisdiction
12、of ASTM Committee D22 on AirQuality and is the direct responsibility of Subcommittee D22.11 on Meteorology.Current edition approved October 10, 2002. Published December 2002. Origi-nally published as D 4230 83. Last previous edition D 4230 83(96)e1.2For referenced ASTM standards, visit the ASTM webs
13、ite, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United Stat
14、es.6. Interferences6.1 This method is not applicable if other constituents in theatmosphere condense before water vapor.7. Apparatus7.1 Dew-point hygrometers, specifically designed for me-teorological observations are available commercially. A sche-matic arrangement of a typical optical dew-point hy
15、grometer isshown in Fig. 1.7.1.1 The sample air flows through a small chamber.7.1.2 Within the chamber is a mirror or surface on which thecondensate can be deposited.7.1.3 A beam of light from an incandescent lamp, lightemitting diode or other suitable light source shines on themirror.7.1.4 Dew or f
16、rost is detected with an electro-optic device.7.1.5 The mirror is cooled by a Peltier thermoelectricelement. Peltier cooling is a convenient method for unattendedand automatic instruments.7.1.6 Preferred devices of sensing mirror temperature areresistance thermometers, thermistors, and thermocouples
17、.7.1.6.1 The temperature sensors shall be attached to orembedded in the mirror to measure the temperature of thesurface of the mirror.7.1.7 Suitable control circuitry shall be provided to maintaina constant quantity of condensate on the mirror.7.1.8 Suitable provisions shall be provided to compensat
18、efor the contamination of the surface of the mirror.7.2 Auxiliary Equipment:7.2.1 Provision shall be provided for assuring air flow pastthe dewpoint mirror without changing the pressure in themirror chamber more than 0.5 % from the ambient pressuresurrounding the sensor. An air flow of approximately
19、 1.1 litresper minute is recommended for typical chambers.7.2.2 Readout instrumentation is available with the dew-point hygrometer.8. Precautions8.1 Safety Precautions:8.1.1 The hygrometer shall be packaged in a suitableenclosure for application in industrial or outdoor environment.8.1.2 Electrical
20、connectors and cables shall be suitable forthe industrial or outdoor environment.8.1.3 Appropriate voltage surge protection circuitry must beincorporated.8.2 Technical Precautions:8.2.1 The accuracy of a cooled-surface condensation hy-grometer is degraded by the presence of water-soluble materi-als.
21、 A mirror-cleaning schedule, consistent with the contami-nation rate, is necessary to maintain the initial calibrationaccuracy. The user must determine the required maintenanceschedule for the specific site, by comparison of calibrationsmade before and after cleaning.8.2.2 Caution in performing this
22、 method should be taken ifthe indicated mirror temperature is between 0C and 30C.Below freezing, the initial formation of the condensate on thesurface of a mirror may be either dew or frost. In the case ofnonfiltered atmospheric air, the supercooled water usually doesnot persist long on a mirror sur
23、face and quickly changes tofrost. The only positive method for determining the state of thecondensate is by visual observation of the mirror surface.8.2.2.1 The following illustrates the magnitude of the errorinvolved when dew or frost is not differentiated: The saturationvapor pressure of supercool
24、ed water at 30C corresponds tosaturation vapor pressure of ice at 27.2C; dew pointof 20C corresponds to frost point of 18.0C; 10C dewpoint corresponds to frost point of 8.9C. (The frost pointtemperature is approximately 90 % of the dew-point tempera-ture in degrees Celsius.)8.2.3 A positive method f
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD42302002E1STANDARDTESTMETHODOFMEASURINGHUMIDITYWITHCOOLEDSURFACECONDENSATIONDEWPOINTHYGROMETER 冷却

链接地址:http://www.mydoc123.com/p-516595.html