ASTM D4044-1996(2008) Standard Test Method for (Field Procedure) for Instantaneous Change in Head (Slug) Tests for Determining Hydraulic Properties of Aquifers《测定蓄水层水力特性用水头瞬息变化(冲击).pdf
《ASTM D4044-1996(2008) Standard Test Method for (Field Procedure) for Instantaneous Change in Head (Slug) Tests for Determining Hydraulic Properties of Aquifers《测定蓄水层水力特性用水头瞬息变化(冲击).pdf》由会员分享,可在线阅读,更多相关《ASTM D4044-1996(2008) Standard Test Method for (Field Procedure) for Instantaneous Change in Head (Slug) Tests for Determining Hydraulic Properties of Aquifers《测定蓄水层水力特性用水头瞬息变化(冲击).pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 4044 96 (Reapproved 2008)Standard Test Method for(Field Procedure) for Instantaneous Change in Head (Slug)Tests for Determining Hydraulic Properties of Aquifers1This standard is issued under the fixed designation D 4044; the number immediately following the designation indicates the y
2、ear oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the field procedure for perfo
3、rm-ing an in situ instantaneous change in head (slug) test.1.2 This test method is used in conjunction with an analyti-cal procedure such as Test Method D 4104 to determine aquiferproperties.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It
4、is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 653 Terminology Relating to Soil, Rock, and ContainedFluidsD 4043 Guide for Sel
5、ection of Aquifer Test Method inDetermining Hydraulic Properties by Well TechniquesD 4104 Test Method (Analytical Procedure) for Determin-ing Transmissivity of Nonleaky Confined Aquifers byOverdamped Well Response to Instantaneous Change inHead (Slug Tests)D 4750 Test Method for Determining Subsurfa
6、ce LiquidLevels in a Borehole or Monitoring Well (ObservationWell)D 5785 Test Method for (Analytical Procedure) for Deter-mining Transmissivity of Confined Nonleaky Aquifers byUnderdamped Well Response to Instantaneous Change inHead (Slug Test)D 5881 Test Method for (Analytical Procedure) Determin-i
7、ng Transmissivity of Confined Nonleaky Aquifers byCritically Damped Well Response to InstantaneousChange in Head (Slug)D 5912 Test Method for (Analytical Procedure) Determin-ing Hydraulic Conductivity of an Unconfined Aquifer byOverdamped Well Response to Instantaneous Change inHead (Slug)3. Termino
8、logy3.1 Definitions:3.1.1 control wellwell by which the aquifer is stressed, forexample, by pumping, injection, or change of head.3.1.2 hydraulic conductivity(field aquifer tests), the vol-ume of water at the existing kinematic viscosity that will movein a unit time under a unit hydraulic gradient t
9、hrough a unitarea measured at right angles to the direction of flow.3.1.3 observation wella well open to all or part of anaquifer.3.1.4 overdamped-well responsecharacterized by the wa-ter level returning to the static level in an approximatelyexponential manner following a sudden change in water lev
10、el.(See for comparison underdamped well.)3.1.5 sluga volume of water or solid object used to inducea sudden change of head in a well.3.1.6 storage coeffcientthe volume of water an aquiferreleases from or takes into storage per unit surface area of theaquifer per unit change in head. For a confined a
11、quifer, it isequal to the product of specific storage and aquifer thickness.For an unconfined aquifer, the storage coefficient is approxi-mately equal to the specific yield.3.1.7 transmissivitythe volume of water at the existingkinematic viscosity that will move in a unit time under a unithydraulic
12、gradient through a unit width of the aquifer.3.1.8 underdamped-well responsecharacterized by thewater level oscillating about the static water level following asudden change in water level. (See for comparison overdampedwell.)3.1.9 For definitions of other terms used in this test method,refer to Ter
13、minology D 653.4. Summary of Test Method4.1 This test method describes the field procedures involvedin conducting an instantaneous head (slug) test. The slug testmethod involves causing a sudden change in head in a controlwell and measuring the water level response within that controlwell. Head chan
14、ge may be induced by suddenly injecting or1This test method is under the jurisdiction ofASTM Committee D18 on Soil andRock and is the direct responsibility of Subcommittee D18.21 on Ground Water andVadose Zone Investigations.Current edition approved Sept. 15, 2008. Published October 2008. Originally
15、approved in 1991. Last previous edition approved in 2002 as D 4044 96 (2002).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page ont
16、he ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.removing a known quantity or “slug” of water into the well,rapid removal of a mechanical “slug” from below the waterlevel, increasing or decreasing the air pressure in t
17、he wellcasing, or emplacement of a mechanical slug into the watercolumn.4.2 The water-level response in the well is a function of themass of water in the well and the transmissivity and coefficientof storage of the aquifer. One method of analysis of the datafrom this field practice is described in T
18、est Method D 4104.5. Significance and Use5.1 This slug test field procedure is used in conjunction witha slug test analytical procedure, such as Test Method D 4104 toprovide quick and relatively inexpensive estimates of transmis-sivity.5.2 The slug test provides an advantage over pumping testsin tha
19、t it does not require the disposal of the large quantities ofwater that may be produced. This is of special importancewhen testing a potentially contaminated aquifer. However, slugtests reflect conditions near the well, therefore are influencedby near-well conditions, such as gravel pack, poor welld
20、evelopment, and skin effects.5.3 Slug tests may be made in aquifer materials of lowerhydraulic conductivity than generally considered suitable forhydraulic testing with pumping tests.5.4 The method of data analysis (analytical procedure)should be known prior to the field testing to ensure that allap
21、propriate dimensions and measurements are properly re-corded. Selection of the analytical procedure can be aided byusing Guide D 4043, Test Method D 5785, Test MethodD 5881, and Test Method D 5912.6. Apparatus6.1 Slug-Inducing EquipmentThis test method describesthe types of equipment that can be use
22、d. Because of the infinitevariety of testing conditions and because similar results can beachieved with different apparatus, engineering specificationsfor apparatus are not appropriate. This test method specifies theresults to be achieved by the equipment to satisfy the require-ments of this practic
23、e.6.2 Water-Level Measurement EquipmentThe method ofwater level measurement may be dependent on the methodselected for injection or withdrawal of water, and the nature ofthe response of the well. For an open-well test, that is, whereaccess to the water level is open to the surface, measure waterleve
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD404419962008STANDARDTESTMETHODFORFIELDPROCEDUREFORINSTANTANEOUSCHANGEINHEADSLUGTESTSFORDETERMININGHYDRAULICPROPERTIESOFAQUIFERS

链接地址:http://www.mydoc123.com/p-516132.html