ASTM D4044-1996(2002) Standard Test Method for (Field Procedure) for Instantaneous Change in Head (Slug) Tests for Determining Hydraulic Properties of Aquifiers《测定蓄水层水力特性用水头瞬息变化(冲击.pdf
《ASTM D4044-1996(2002) Standard Test Method for (Field Procedure) for Instantaneous Change in Head (Slug) Tests for Determining Hydraulic Properties of Aquifiers《测定蓄水层水力特性用水头瞬息变化(冲击.pdf》由会员分享,可在线阅读,更多相关《ASTM D4044-1996(2002) Standard Test Method for (Field Procedure) for Instantaneous Change in Head (Slug) Tests for Determining Hydraulic Properties of Aquifiers《测定蓄水层水力特性用水头瞬息变化(冲击.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 4044 96 (Reapproved 2002)Standard Test Method(Field Procedure) for Instantaneous Change in Head (Slug)Tests for Determining Hydraulic Properties of Aquifiers1This standard is issued under the fixed designation D 4044; the number immediately following the designation indicates the year
2、 oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the field procedure for perform
3、-ing an in situ instantaneous change in head (slug) test.1.2 This test method is used in conjunction with an analyti-cal procedure such as Test Method D 4104 to determine aquiferproperties.1.3 The values stated in the SI units are to be regarded asstandard.1.4 This standard does not purport to addre
4、ss all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:D 653 Terminolog
5、y Relating to Soil, Rock, and ContainedFluids2D 4043 Guide for Selection of Aquifer-Test Method inDetermination of Hydraulic Properties by Well Tech-niques2D 4104 Test Method (Analytical Procedure) for Determin-ing Transmissivity of Confined Nonleaky Aquifers byOverdamped Well Response to Instantane
6、ous Change inHead (Slug Test)2D 4750 Test Method for Determining Subsurface LiquidLevels in a Borehole or Monitoring Well (ObservationWell)2D 5785 Test Method for (Analytical Procedure) for Deter-mining Transmissivity of Confined Nonleaky Aquifers byUnderdamped Well Response to Instantaneous Change
7、InHead (Slug Test)3D 5881 Test Method (Analytical Procedure) for Determin-ing Transmissivity of Confined Nonleaky Aquifers byCritically Damped Well Response to InstantaneousChange In Head (Slug Test)3D 5912 Test Method (Analytical Procedure) for Determin-ing Hydraulic Conductivity of an Unconfined A
8、quifer byOverdamped Well Response to Instantaneous Change InHead (Slug Test)33. Terminology3.1 Definitions: Definitions:3.1.1 control wellwell by which the aquifer is stressed, forexample, by pumping, injection, or change of head.3.1.2 hydraulic conductivity(field aquifer tests), the vol-ume of wate
9、r at the existing kinematic viscosity that will movein a unit time under a unit hydraulic gradient through a unitarea measured at right angles to the direction of flow.3.1.3 observation wella well open to all or part of anaquifer.3.1.4 overdamped-well responsecharacterized by the wa-ter level return
10、ing to the static level in an approximatelyexponential manner following a sudden change in water level.(See for comparison underdamped well.)3.1.5 sluga volume of water or solid object used to inducea sudden change of head in a well.3.1.6 storage coeffcientthe volume of water an aquiferreleases from
11、 or takes into storage per unit surface area of theaquifer per unit change in head. For a confined aquifer, it isequal to the product of specific storage and aquifer thickness.For an unconfined aquifer, the storage coefficient is approxi-mately equal to the specific yield.3.1.7 transmissivitythe vol
12、ume of water at the existingkinematic viscosity that will move in a unit time under a unithydraulic gradient through a unit width of the aquifer.3.1.8 underdamped-well responsecharacterized by thewater level oscillating about the static water level following asudden change in water level. (See for c
13、omparison overdampedwell.)3.1.9 For definitions of other terms used in this test method,refer to Terminology D 653.4. Summary of Test Method4.1 This test method describes the field procedures involvedin conducting an instantaneous head (slug) test. The slug testmethod involves causing a sudden chang
14、e in head in a controlwell and measuring the water level response within that controlwell. Head change may be induced by suddenly injecting or1This test method is under the jurisdiction of ASTM Committee D18 on Soil andRock and is the direct responsibility of Subcommittee D18.21 on Ground Water andV
15、adose Zone Investigations.Current edition approved Oct. 10, 1997. Published February 1997. Originallypublished as D 4044 91. Last previous edition D 4044 91.2Annual Book of ASTM Standards, Vol 04.08.3Annual Book of ASTM Standards, Vol 04.091Copyright ASTM International, 100 Barr Harbor Drive, PO Box
16、 C700, West Conshohocken, PA 19428-2959, United States.removing a known quantity or “slug” of water into the well,rapid removal of a mechanical “slug” from below the waterlevel, increasing or decreasing the air pressure in the wellcasing, or emplacement of a mechanical slug into the watercolumn.4.2
17、The water-level response in the well is a function of themass of water in the well and the transmissivity and coefficientof storage of the aquifer. One method of analysis of the datafrom this field practice is described in Test Method D 4104.5. Significance and Use5.1 This slug test field procedure
18、is used in conjunction witha slug test analytical procedure, such as Test Method D 4104 toprovide quick and relatively inexpensive estimates of transmis-sivity.5.2 The slug test provides an advantage over pumping testsin that it does not require the disposal of the large quantities ofwater that may
19、be produced. This is of special importancewhen testing a potentially contaminated aquifer. However, slugtests reflect conditions near the well, therefore are influencedby near-well conditions, such as gravel pack, poor welldevelopment, and skin effects.5.3 Slug tests may be made in aquifer materials
20、 of lowerhydraulic conductivity than generally considered suitable forhydraulic testing with pumping tests.5.4 The method of data analysis (analytical procedure)should be known prior to the field testing to ensure that allappropriate dimensions and measurements are properly re-corded. Selection of t
21、he analytical procedure can be aided byusing Guide D 4043, Test Method D 5785, Test MethodD 5881, and Test Method D 5912.6. Apparatus6.1 Slug-Inducing EquipmentThis test method describesthe types of equipment that can be used. Because of the infinitevariety of testing conditions and because similar
22、results can beachieved with different apparatus, engineering specificationsfor apparatus are not appropriate. This test method specifies theresults to be achieved by the equipment to satisfy the require-ments of this practice.6.2 Water-Level Measurement EquipmentThe method ofwater level measurement
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD404419962002STANDARDTESTMETHODFORFIELDPROCEDUREFORINSTANTANEOUSCHANGEINHEADSLUGTESTSFORDETERMININGHYDRAULICPROPERTIESOFAQUIFIERS

链接地址:http://www.mydoc123.com/p-516131.html