ASTM D3988-2005(2011) Standard Test Method for Vanadium in Paint Driers by EDTA Method《EDTA法涂料催干剂中钒的标准试验方法》.pdf
《ASTM D3988-2005(2011) Standard Test Method for Vanadium in Paint Driers by EDTA Method《EDTA法涂料催干剂中钒的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3988-2005(2011) Standard Test Method for Vanadium in Paint Driers by EDTA Method《EDTA法涂料催干剂中钒的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D3988 05 (Reapproved 2011)Standard Test Method forVanadium in Paint Driers by EDTA Method1This standard is issued under the fixed designation D3988; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revi
2、sion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the titrimetric determination ofvanadium in liquid vanadium driers and utilizes the disodiumsalt of eth
3、ylenediaminetetraacetic acid dihydrate (EDTA).1.2 This test method is limited to the determination of thevanadium content of a liquid vanadium drier that does notcontain other drier elements. This test method is not applicableto drier blends.1.3 All cations that can be titrated with EDTA in alkaline
4、media interfere and must not be present in the sample.1.4 This test method has been tested for concentrations of 3and 4 % vanadium, but there is no reason to believe that it isnot suitable for higher or lower vanadium concentrationsprovided specimen size is adjusted proportionately.1.5 The values st
5、ated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety
6、and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D600 Specification for Liquid Paint DriersD1193 Specification for Reagent WaterE180 Practice for Determining the Precision of ASTMMethods for Analysis and Testing o
7、f Industrial and Spe-cialty Chemicals3E300 Practice for Sampling Industrial Chemicals3. Summary of Test Method3.1 The amount of vanadium drier used in oxidizing-typecoatings significantly affects their drying properties. The vana-dium drier is acidified and heated to make the vanadiumavailable for c
8、helation with EDTA. It is then chelated, the pHadjusted, and the excess titrated with zinc chloride solution,using Eriochrome Black T as the indicator.4. Significance and Use4.1 This test method may be used to confirm the statedcontent of a pure liquid vanadium drier manufactured for useby the coati
9、ngs industry.5. Apparatus5.1 Centrifuge, capable of developing 1000 to 2000 g.6. Reagents6.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents o
10、f the American Chemical Society,where such specifications are available.4Other grades may beused, provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.6.2 Purity of WaterUnless otherwise indicated, refere
11、nceto water shall be understood to mean reagent water conformingto Type II of Specification D1193.6.3 Ammonium Hydroxide (sp gr 0.90)Concentrated am-monium hydroxide (NH4OH).6.4 Ascorbic Acid.6.5 Buffer SolutionAdd 350 mL of concentrated NH4OHto 54 g of ammonium chloride and dilute to 1 L with water
12、.6.6 Eriochrome Black T IndicatorMix and grind thor-oughly in a mortar a mixture of 0.2 g of Eriochrome Black T1This test method is under the jurisdiction of ASTM Committee D01 on Paintand Related Coatings, Materials, and Applications and is the direct responsibility ofSubcommittee D01.21 on Chemica
13、l Analysis of Paints and Paint Materials.Current edition approved June 1, 2011. Published June 2011. Originallyapproved in 1981. Last previous edition approved in 2005 as D3988 05 . DOI:10.1520/D3988-05R11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer
14、Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn. The last approved version of this historical standard is referencedon www.astm.org.4Reagent Chemicals, American Chemical Society Specifications
15、, AmericanChemical Society, Washington, DC. For suggestions on the testing of reagents notlisted by the American Chemical Society, see Analar Standards for LaboratoryChemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeiaand National Formulary, U.S. Pharmacopeial Convention, Inc
16、. (USPC), Rockville,MD.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.and 100 g of sodium chloride. Store the mixture in a tightlystoppered bottle where it is stable indefinitely.6.7 EDTA, Standard Solution (0.01 M)Weigh about 3.73g
17、 of EDTA to the nearest 0.01 g, dissolve in water, and diluteto approximately 1 L in a glass-stoppered bottle.6.8 Hydrochloric Acid (sp gr 1.19)Concentrated hydro-chloric acid (HCl).6.9 Isopropyl Alcohol, 99.5 %.6.10 Zinc Chloride, Standard Solution (ZnCl2) (0.01 M)Weigh about 0.65 g of zinc (Note 1
18、) to 5 mg. Transfer to a 1-Lvolumetric flask, and add 25 mL of dilute hydrochloric acid(1 + 3). Warm if necessary on a steam bath to dissolve thematerial completely. Cool, dilute to the mark with water andmix thoroughly.NOTE 1Store the zinc ribbon in a tightly closed container to preventthe surface
19、of the zinc from oxidizing.7. Sampling7.1 Take a small sample of liquid drier from bulk using theprocedure in Practice E300 appropriate for the size of thecontainer: section on Bottle Sampling for tanks and tank cars,or section on Tube Sampling for drums and cans.NOTE 2Liquid driers are normally hom
20、ogeneous so that only simplephysical tests, such as specific gravity or solids content, on top and bottomsamples from tanks, are required to confirm that separation has notoccurred. Agitate the drums in accordance with the section on TubeSampling of Practice E300.7.2 Examine the sample of drier for
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD398820052011STANDARDTESTMETHODFORVANADIUMINPAINTDRIERSBYEDTAMETHODEDTA 涂料 催干剂 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-515977.html