ASTM D3988-2005 Standard Test Method for Vanadium in Paint Driers by EDTA Method《EDTA法测定涂料干燥剂中钒的标准试验方法》.pdf
《ASTM D3988-2005 Standard Test Method for Vanadium in Paint Driers by EDTA Method《EDTA法测定涂料干燥剂中钒的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3988-2005 Standard Test Method for Vanadium in Paint Driers by EDTA Method《EDTA法测定涂料干燥剂中钒的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3988 05Standard Test Method forVanadium in Paint Driers by EDTA Method1This standard is issued under the fixed designation D 3988; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number i
2、n parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the titrimetric determination ofvanadium in liquid vanadium driers and utilizes the disodiumsalt of ethylenediaminetet
3、raacetic acid dihydrate (EDTA).1.2 This test method is limited to the determination of thevanadium content of a liquid vanadium drier that does notcontain other drier elements. This test method is not applicableto drier blends.1.3 All cations that can be titrated with EDTA in alkalinemedia interfere
4、 and must not be present in the sample.1.4 This test method has been tested for concentrations of 3and 4 % vanadium, but there is no reason to believe that it isnot suitable for higher or lower vanadium concentrationsprovided specimen size is adjusted proportionately.1.5 The values stated in SI unit
5、s are to be regarded as thestandard. The values given in parentheses are for informationonly.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health prac
6、tices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 600 Specification for Liquid Paint DriersD 1193 Specification for Reagent WaterE 180 Practice for Determining the Precision of ASTMMethods for Analysis and Testing of Industrial
7、 ChemicalsE 300 Practice for Sampling Industrial Chemicals3. Summary of Test Method3.1 The amount of vanadium drier used in oxidizing-typecoatings significantly affects their drying properties. The vana-dium drier is acidified and heated to make the vanadiumavailable for chelation with EDTA. It is t
8、hen chelated, the pHadjusted, and the excess titrated with zinc chloride solution,using Eriochrome Black T as the indicator.4. Significance and Use4.1 This test method may be used to confirm the statedcontent of a pure liquid vanadium drier manufactured for useby the coatings industry.5. Apparatus5.
9、1 Centrifuge, capable of developing 1000 to 2000 g.6. Reagents6.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Soc
10、iety,where such specifications are available.3Other grades may beused, provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.6.2 Purity of WaterUnless otherwise indicated, referenceto water shall be unders
11、tood to mean reagent water conformingto Type II of Specification D 1193.6.3 Ammonium Hydroxide (sp gr 0.90)Concentrated am-monium hydroxide (NH4OH).6.4 Ascorbic Acid.6.5 Buffer SolutionAdd 350 mL of concentrated NH4OHto 54 g of ammonium chloride and dilute to 1 L with water.6.6 Eriochrome Black T In
12、dicatorMix and grind thor-oughly in a mortar a mixture of 0.2 g of Eriochrome Black Tand 100 g of sodium chloride. Store the mixture in a tightlystoppered bottle where it is stable indefinitely.6.7 EDTA, Standard Solution (0.01 M)Weigh about 3.73g of EDTA to the nearest 0.01 g, dissolve in water, an
13、d diluteto approximately 1 L in a glass-stoppered bottle.6.8 Hydrochloric Acid (sp gr 1.19)Concentrated hydro-chloric acid (HCl).1This test method is under the jurisdiction of ASTM Committee D01 on Paintand Related Coatings, Materials, and Applications and is the direct responsibility ofSubcommittee
14、 D01.21 on Chemical Analysis of Paints and Paint Materials.Current edition approved Jan. 1, 2005. Published February 2005. Originallyapproved in 1981. Last previous edition approved in 1999 as D 3988 85 (1999).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Custo
15、mer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Reagent Chemicals, American Chemical Society Specifications, AmericanChemical Society, Washington, DC. For suggestions on the testing of reagents notl
16、isted by the American Chemical Society, see Analar Standards for LaboratoryChemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeiaand National Formulary, U.S. Pharmacopeial Convention, Inc. (USPC), Rockville,MD.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, W
17、est Conshohocken, PA 19428-2959, United States.6.9 Isopropyl Alcohol, 99.5 %.6.10 Zinc Chloride, Standard Solution (ZnCl2) (0.01 M)Weigh about 0.65 g of zinc (Note 1) to 5 mg. Transfer to a 1-Lvolumetric flask, and add 25 mL of dilute hydrochloric acid(1 + 3). Warm if necessary on a steam bath to di
18、ssolve thematerial completely. Cool, dilute to the mark with water andmix thoroughly.NOTE 1Store the zinc ribbon in a tightly closed container to preventthe surface of the zinc from oxidizing.7. Sampling7.1 Take a small sample of liquid drier from bulk using theprocedure in Practice E 300 appropriat
19、e for the size of thecontainer: section on Bottle Sampling for tanks and tank cars,or section on Tube Sampling for drums and cans.NOTE 2Liquid driers are normally homogeneous so that only simplephysical tests, such as specific gravity or solids content, on top and bottomsamples from tanks, are requi
20、red to confirm that separation has notoccurred. Agitate the drums in accordance with the section on TubeSampling of Practice E 300.7.2 Examine the sample of drier for sediment or suspendedmatter which, if present, is evidence of noncompliance withSpecification D 600.7.3 If the sample is homogeneous
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD39882005STANDARDTESTMETHODFORVANADIUMINPAINTDRIERSBYEDTAMETHODEDTA 测定 涂料 干燥剂 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-515976.html