1、Designation: D 3943 04Standard Test Method forTotal Molybdenum in Fresh Alumina-Base Catalysts1This standard is issued under the fixed designation D 3943; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A
2、 number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of molybde-num in alumina-base catalysts and has been cooperativelytested at molybdenum con
3、centrations from 8 to 18 weight %,expressed as MoO3. Any component of the catalyst other thanmolybdenum such as iron, tungsten, etc., which is capable ofbeing oxidized by either ferric or ceric ions after being passedthrough a zinc-amalgam reductor column (Jones reductor) willinterfere.1.2 This stan
4、dard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 A
5、STM Standards:2D 1193 Specification for Reagent WaterE 173 Practice for Conducting Interlaboratory Studies ofMethods for Chemical Analysis of Metals3E 507 Test Method for Aluminum in Iron Ores by AtomicAbsorption Spectroscopy3. Summary of Test Method3.1 The catalyst is digested in hot sulfuric acid
6、to dissolvemolybdenum, destroy organic matter, and to expel nitrates ifpresent. The acid solution is diluted and passed through anamalgamated zinc column (Jones reductor) into a receivingflask containing an excess of ferric ammonium sulfate. Thecolumn quantitatively reduces the molybdenum (Mo+6toMo+
7、3) which in turn is reoxidized in the receiving flaskaccording to the reaction:Mo131 3Fe1 3 Mo1 61 3Fe1 2(1)3.2 The ferrous ion produced (three per Mo+3oxidized) istitrated with standard ceric sulfate solution in the presence offerroin indicator. The indicator undergoes a color change (pinkto colorl
8、ess or very faint blue-green) in the presence of excessceric ion. The amount of Fe+2titrated in the reactionFe1 21 Ce1 4 Fe1 31 Ce1 3(2)is a direct measure of Mo+6concentration.4. Significance and Use4.1 This test method sets forth a procedure by whichcatalyst samples can be compared either on an in
9、terlaboratoryor intralaboratory basis. It is anticipated that catalyst producersand users will find this method of value.5. Interferences5.1 Elements such as As, Sb, Cr, Fe, Ti, V, U, or W caninterfere in this analysis. If serious interference occurs, it willbe necessary to isolate the molybdenum fr
10、om the interferingspecies prior to measurement.5.2 Organics and nitrates can interfere or react with thezinc-amalgam if the sulfuric acid treatment is not properlycarried out as described in 9.1.6. Apparatus6.1 Beakers, 250-mL.6.2 Jones Reductor Column, 30-cm long by 2 cm in outerdiameter, with a 10
11、0-mL reservoir.4Attach a piece of vinyltubing to the end of the delivery tube long enough to extend tothe bottom of the filtering flask (see Test Method E 507).6.3 Vacuum Filtering Flask, heavy-walled, 1000-mL.6.4 Buret, 50-mL, Class A (0.1-mL divisions).6.5 Stirring Motor, magnetic, and TFE-fluoroc
12、arbon-covered stirring bars, 7.11 by 14.2 mm (516 by 1916 in.).1This test method is under the jurisdiction of ASTM Committee D32 onCatalysts and is the direct responsibility of Subcommittee D32.03 on ChemicalComposition.Current edition approved April 1, 2004. Published April 2004. Originallyapproved
13、 in 1980. Last previous edition approved in 2000 as D 394300.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.
14、3Withdrawn.4The sole source of supply of the apparatus known to the committee at this timeis Part No. 8035-J10 from Thomas Scientific, 99 High Hill Rd. at 295, Swedesboro,NJ 08085. If you are aware of alternative suppliers, please provide this informationto ASTM International Headquarters. Your comm
15、ents will receive careful consid-eration at a meeting of the responsible technical committee,1which you may attend.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.7. Reagents7.1 Purity of ReagentsReagent grade chemicals shall beused
16、in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,where such specifications are available.5Other grades may beused provided it is first ascertained that the reagent i
17、s ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.7.2 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean reagent water conformingto Specification D 1193.7.3 Ceric Sulfate, 0.10 N standardized using sodium mo-lybda
18、te following the procedure given in Annex A2.7.4 Ferric Ammonium Sulfate SolutionFeNH4(SO4)212H2ODissolve 200 g of FeNH4(SO4)212 H2O in 1000 mLof water containing 20 mL of concentrated sulfuric acid. Addpotassium permanganate solution dropwise until a pink colorpersists for 1 min.7.5 Ferroin Indicat
19、or, 0.025 M solution of 1, 10-phenanthroline ferrous sulfate complex.7.6 Hydrocholoric Acid (HCl), concentrated.7.7 Jones Reductor Amalgam.7.8 Mercuric Chloride (HgCl2) Solution, approximately2 %. Dissolve 10 g of mercuric chloride (HgCl2) in water.Transfer to a 500mL volumetric flask, dilute to vol
20、ume, andmix.7.9 Molybdenum Standard SolutionDissolve 1.0 g,weighed to the nearest 0.1 mg, of sodium molybdate dihydrate(Na2MoO42H2O) in water containing 10 mL of H2SO4,transfer to a 1-L volumetric flask, dilute to volume, and mix(1 mL = 0.5948 mg MoO3).7.10 Phosphoric Acid (H3PO4), concentratedMix 1
21、30mL of concentrated H2SO4with 250 mL of water. Add the acidslowly with constant stirring. Add 140 mL of concentratedH3PO4and 15 mL of a saturated solution ofMnSO4(approximately 60 g/100 mL). Dilute to 1000 mL withwater.7.11 Potassium Permanganate (KMnO4), approximately0.1 M solution.7.12 Sulfuric A
22、cid (H2SO4), concentrated, 1 + 1 and1 + 19, dilutions with water, corresponding to 18 and 1.8 Nsolutions, respectively. Cautiously add the concentrated sulfu-ric acid to the water, mix well, and allow to cool.7.13 Sulfuric Acid (H2SO4), dilute, 1 + 99, warm, dilutionswith water, corresponding to 0.1
23、8 N solution. Cautiously addthe concentrated sulfuric acid to the water and mix well.7.14 Zinc Metal, 20 mesh, low iron content.8. Sampling8.1 The selection of a representative analytical sample fromthe bulk material is outside the scope of the present method. Itis presumed that parties using this t
24、est method for comparisonpurposes will have agreed on the selection of an analyticalsample which is appropriate to their needs.8.2 Pulverize the analytical sample to pass a 150-m (No.100) sieve. Ignite the pulverized sample for 30 min at 550C ina muffle furnace. Allow to cool in a desiccator.9. Proc
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD39432004STANDARDTESTMETHODFORTOTALMOLYBDENUMINFRESHALUMINABASECATALYSTS 新制 氧化铝 催化剂 中总钼量 标准 试验 方法

链接地址:http://www.mydoc123.com/p-515867.html