《ASTM D3934-2014 Standard Test Method for Flash No Flash TestEquilibrium Method by a Closed-Cup Apparatus《采用闭杯装置平衡法的闪光 无闪光试验的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3934-2014 Standard Test Method for Flash No Flash TestEquilibrium Method by a Closed-Cup Apparatus《采用闭杯装置平衡法的闪光 无闪光试验的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D3934 90 (Reapproved 2007)D3934 14Standard Test Method forFlash/No Flash TestEquilibrium Method by a Closed-CupApparatus1This standard is issued under the fixed designation D3934; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONASTM Flash Point Test Methods D56, D93, D3278, and D3941 are specified by governmentdepartments
3、and agencies for determining whether liquids are flammable or combustible. Theseclassifications are used as the basis for regulating the handling and shipping of liquids.ISO/TC 35, Paints and Varnishes, and ISO/TC 28, Petroleum and Related Products, have issued ISO1516 as a common standard, applicab
4、le to paints, varnishes, petroleum, and related products. Thismethod is similar to ISO 1516 but uses standard ASTM cups and style and format. Test MethodsD3278 and D3828 operate on the equilibrium principle by using the Setaflash tester that has atemperature-control device.This test method does not
5、determine the finite flash point but whether or not flashing occurs at asingle specified temperature. The latter determination is made more accurate by ensuring that the testis carried out only when the material under test and the air/vapor mixture above it are in approximateequilibrium at the speci
6、fied temperature.1. Scope Scope*1.1 This test method covers the determination of whether a liquid complies with the closed-cup flash point requirements ingovernment regulations, or in specifications, or as agreed between the purchaser and the seller.1.2 This test method is limited to a temperature r
7、ange between 0 and 110C (32 and 230F).1.3 The values stated in SIinch-pound units are to be regarded as the standard. The values given in parentheses are forinformation only.mathematical conversions to SI units that are provided for information only and are not considered standard.1.4 WarningMercury
8、 has been designated by many regulatory agencies as a hazardous material that can cause centralnervous system, kidney and liver damage. Mercury, or its vapor, may be hazardous to health and corrosive to materials. Cautionshould be taken when handling mercury and mercury containing products. See the
9、applicable product Safety Data Sheet (SDS) fordetails and EPAs website, http:/www.epa.gov/mercury/faq.htm, for additional information. Users should be aware that sellingmercury and/or mercury containing products into your state or country may be prohibited by law.1.5 This standard should be used to
10、measure and describe the properties of materials, products, or assemblies in response toheat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard or fire riskof materials, products, or assemblies under actual fire conditions. However, result
11、s of this test may be used as elements of a firerisk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard of a particularend use.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is
12、the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.1 This test method is under the jurisdiction of ASTM Committee D01 on Paint and Related Coatings, Materials, and Applications and
13、is the direct responsibility of ASTMSubcommittee D01.21 on Chemical Analysis of Paints and Paint Materials.Current edition approved June 1, 2007Dec. 15, 2014. Published June 2007January 2015. Originally approved in 1982. Last previous edition approved in 20012007 asD3934 90 (2001).(2007). DOI: 10.15
14、20/D3934-90R07.10.1520/D3934-14.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recomme
15、nds that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700,
16、 West Conshohocken, PA 19428-2959. United States12. Referenced Documents2.1 ASTM Standards:2D56 Test Method for Flash Point by Tag Closed Cup TesterD93 Test Methods for Flash Point by Pensky-Martens Closed Cup TesterD3278 Test Methods for Flash Point of Liquids by Small Scale Closed-Cup ApparatusD38
17、28 Test Methods for Flash Point by Small Scale Closed Cup TesterD3941 Test Method for Flash Point by the Equilibrium Method With a Closed-Cup ApparatusE1 Specification for ASTM Liquid-in-Glass ThermometersE1137 Specification for Industrial Platinum Resistance ThermometersE2251 Specification for Liqu
18、id-in-Glass ASTM Thermometers with Low-Hazard Precision LiquidsE2877 Guide for Digital Contact Thermometers2.2 ISO Standard:ISO 1516 Paints, varnishes, petroleum, and related productsFlash/no-flash testClosed cup equilibrium method33. Terminology3.1 Definitions:3.1.1 flash point, nthe lowest tempera
19、ture corrected to a pressure of 760 mm Hg (101.3 kPa) (1013 millibars) at whichapplication of an ignition source causes the vapor of the specimen to ignite under specified conditions of test.4. Summary of Test Method4.1 A specimen in a closed cup of standard design is heated in a suitable liquid bat
20、h. After the specimen has been maintainedunder equilibrium conditions for at least 10 min at the lowest allowable flash point temperature (within a permitted tolerance) ofthe specification or regulation, it is determined whether the specimen does or does not flash.5. Significance and Use5.1 This tes
21、t method ensures that before the flash test is run the air/vapor space above the specimen has attained a saturationconcentration of vapor by using standard closed cups under equilibrium conditions. The saturation concentration of the vapors willbe attained at some temperature between that of the liq
22、uid and the cooler apparatus lid. However, this temperature will be closeto the temperature of the specimen after it has been maintained at the specified temperature for at least a 10-min period. This testmethod does not provide for the determination of the actual flash point but only whether a spec
23、imen does or does not flash at aspecified temperature.6. Apparatus6.1 Test Cups, specified in Test Methods D56 (Tag) and D93 (Pensky-Martens). Remove the test cup assembly (including lidand specimen thermometer) from the Tag and Pensky-Martens apparatus to permit either to be used in a separate wate
24、r bath.NOTE 1If a stirrer is fitted to the test cup, it shall be operated during the heating period but must be stopped during the flashing determination. Ifa stirrer originally fitted to the test cup is removed, the aperture in the cover shall be securely plugged before starting the test.6.2 Liquid
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD39342014STANDARDTESTMETHODFORFLASHNOFLASHTESTEQUILIBRIUMMETHODBYACLOSEDCUPAPPARATUS 采用 装置 平衡 闪光

链接地址:http://www.mydoc123.com/p-515841.html