ASTM D3890-2018 Standard Practice for Number of Strokes to Prime a Mechanical Pump Dispenser.pdf
《ASTM D3890-2018 Standard Practice for Number of Strokes to Prime a Mechanical Pump Dispenser.pdf》由会员分享,可在线阅读,更多相关《ASTM D3890-2018 Standard Practice for Number of Strokes to Prime a Mechanical Pump Dispenser.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D3890 05 (Reapproved 2010)D3890 18Standard Test Method Practice forNumber of Strokes to Prime a Mechanical Pump Dispenser1This standard is issued under the fixed designation D3890; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、 revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method practice covers the determination of the number of actuations required to prim
3、e a pump dispenser (sprayand flow types) with a consumer-type product.1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety safety, health, and healthenvironmenta
4、l practices and determine theapplicability of regulatory limitations prior to use.1.3 This international standard was developed in accordance with internationally recognized principles on standardizationestablished in the Decision on Principles for the Development of International Standards, Guides
5、and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Significance and Use2.1 This test method practice can be used to visually compare priming characteristics of different pump dispensers and differentproducts.2.2 This test method practice is suita
6、ble for establishing specifications for both the pump dispenser and the final package.3. Apparatus3.1 No apparatus is required, although a mechanical device for actuating the pump dispenser may be used.4. Sampling4.1 Select an appropriate number of dry, unused pump dispensers at random for the preci
7、sion and accuracy desired. A numberof ten test specimens are recommended, but a minimum of three is acceptable.5. Conditioning5.1 If possible, condition the test specimens at 23 6 3C (73 6 5.4F) for not less than 4 h. If the test specimens are notconditioned at the recommended temperature, this shou
8、ld be noted in the test report discussed in 8.1.5.2 Test pumps should be tested no sooner than 24 h after assembly when possible. If the pumps are not conditioned at therecommended time, this should be noted in the test report discussed in 8.1.6. Test Specimens6.1 For each test specimen, select a co
9、ntainer to which the pump dispenser will be attached during the test. Since the dip tubelength affects the number of strokes to prime, the actual bottle of the final package is recommended for testing.7. Procedure7.1 Fill each container with the product to be tested at the actual level of the final
10、package target weight.7.2 Attach the pump dispenser securely to the container. The pump should be in the off, locked, or closed position. Take carenot to actuate the pump dispenser during this step.NOTE 1If the actuator is placed onto the pump after the pump has been secured onto the container, then
11、 report this additional stroke in the final resultsin 8.1.1 This test method practice is under the jurisdiction ofASTM Committee F02 on FlexiblePrimary Barrier Packaging and is the direct responsibility of Subcommittee F02.30on Mechanical Pump Dispensers.Current edition approved Oct. 1, 2010May 1, 2
12、018. Published March 2011June 2018. Originally approved in 1980. Last previous edition approved in 20052010 asD3890 05.D3890 05 (2010). DOI: 10.1520/D3890-05R10.10.1520/D3890-18.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what c
13、hanges have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the of
14、ficial document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1NOTE 2If an actuation is required when opening or unlocking the pump, then report this additional actuation in the test report discussed in 8.1.7.3 If the pump dispenser
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD38902018STANDARDPRACTICEFORNUMBEROFSTROKESTOPRIMEAMECHANICALPUMPDISPENSERPDF

链接地址:http://www.mydoc123.com/p-515737.html