ASTM D3890-2005(2010) Standard Test Method for Number of Strokes to Prime a Mechanical Pump Dispenser《起动机械泵分配器插程数的标准试验方法》.pdf
《ASTM D3890-2005(2010) Standard Test Method for Number of Strokes to Prime a Mechanical Pump Dispenser《起动机械泵分配器插程数的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3890-2005(2010) Standard Test Method for Number of Strokes to Prime a Mechanical Pump Dispenser《起动机械泵分配器插程数的标准试验方法》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D3890 05 (Reapproved 2010)Standard Test Method forNumber of Strokes to Prime a Mechanical Pump Dispenser1This standard is issued under the fixed designation D3890; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the ye
2、ar of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the numberof actuations required to prime a pump dispenser (spray a
3、ndflow types) with a consumer-type product.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulato
4、ry limitations prior to use.2. Significance and Use2.1 This test method can be used to visually comparepriming characteristics of different pump dispensers and dif-ferent products.2.2 This test method is suitable for establishing specifica-tions for both the pump dispenser and the final package.3. A
5、pparatus3.1 No apparatus is required, although a mechanical devicefor actuating the pump dispenser may be used.4. Sampling4.1 Select an appropriate number of dry, unused pumpdispensers at random for the precision and accuracy desired. Anumber of ten test specimens are recommended, but a mini-mum of
6、three is acceptable.5. Conditioning5.1 If possible, condition the test specimens at 23 6 3C (736 5.4F) for not less than 4 h. If the test specimens are notconditioned at the recommended temperature, this should benoted in the test report discussed in 8.1.5.2 Test pumps should be tested no sooner tha
7、n 24 h afterassembly when possible. If the pumps are not conditioned atthe recommended time, this should be noted in the test reportdiscussed in 8.1.6. Test Specimens6.1 For each test specimen, select a container to which thepump dispenser will be attached during the test. Since the diptube length a
8、ffects the number of strokes to prime, the actualbottle of the final package is recommended for testing.7. Procedure7.1 Fill each container with the product to be tested at theactual level of the final package target weight.7.2 Attach the pump dispenser securely to the container. Thepump should be i
9、n the off, locked, or closed position. Take carenot to actuate the pump dispenser during this step.NOTE 1If the actuator is placed onto the pump after the pump hasbeen secured onto the container, then report this additional stroke in thefinal results in 8.1.NOTE 2If an actuation is required when ope
10、ning or unlocking thepump, then report this additional actuation in the test report discussed in8.1.7.3 If the pump dispenser is equipped with an overcap orlocking feature, remove or release the feature to permit thepump dispenser to be in the operable mode.7.4 If the pump dispenser has a variable o
11、utput-per-strokefeature, make an appropriate adjustment to achieve the desiredoutput-per-stroke at this time. Report this desired dosage in8.1.7.5 Actuate the pump dispenser to its fullest extent withsmooth, firm, and even pressure. Allow the pump mechanismto fully return before beginning the next s
12、troke.NOTE 3Depending on the venting system, some mechanical pumpdispensers can have variation in the number of strokes-to-prime due to thetime that the priming vent is opened. It is suggested that a rate of 90 6 15strokes per minute be used. For some viscous products, this rate may betoo fast for t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD389020052010STANDARDTESTMETHODFORNUMBEROFSTROKESTOPRIMEAMECHANICALPUMPDISPENSER 起动 机械 分配器 插程数 标准

链接地址:http://www.mydoc123.com/p-515736.html