ASTM D3859-2003 Standard Test Methods for Selenium in Water《水中硒含量的标准测试方法》.pdf
《ASTM D3859-2003 Standard Test Methods for Selenium in Water《水中硒含量的标准测试方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3859-2003 Standard Test Methods for Selenium in Water《水中硒含量的标准测试方法》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3859 03Standard Test Methods forSelenium in Water1This standard is issued under the fixed designation D 3859; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicat
2、es the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 These test methods cover the determination of dissolvedand total recoverable selenium in most waters and wastewaters.Both test methods utilize atomic absorption p
3、rocedures, asfollows:SectionsTest Method AGaseous Hydride AAS27to16Test Method BGraphite Furnace AAS 17 to 261.2 These test methods are applicable to both inorganic andorganic forms of dissolved selenium. They are applicable alsoto particulate forms of the element, provided that they aresolubilized
4、in the appropriate acid digestion step. However,certain selenium-containing heavy metallic sediments may notundergo digestion.1.3 These test methods are most applicable within thefollowing ranges:Test Method A 1 to 20 g/LTest Method B 2 to 100 g/LThese ranges may be extended (with a corresponding lo
5、ss inprecision) by decreasing the sample size or diluting the originalsample, but concentrations much greater than the upper limitsare more conveniently determined by flame atomic absorptionspectrometry.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with
6、its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardstatements, see11.12 and 13.14.2. Referenced Documents2.1 ASTM Standards:D 1129 Terminology
7、Relating to Water3D 1193 Specification for Reagent Water3D 2777 Practice for Determination of Precision and Bias ofApplicable Methods of Committee D19 on Water3D 3370 Practices for Sampling Water from Closed Con-duits3D 3919 Practice for Measuring Trace Elements in Water byGraphite Furnace Atomic Ab
8、sorption Spectrophotometry3D 4841 Practice for Estimation of Holding Time for WaterSamples Containing Organic and Inorganic Constituents3D 5810 Guide for Spiking into Aqueous Samples3D 5847 Practice for Writing Quality Control Specificationsfor Standard Test Methods for Water Analysis43. Terminology
9、3.1 Definitions:3.1.1 For definitions of terms used in these test methods,refer to Terminology D 1129.3.2 Definitions of Terms Specific to This Standard:3.2.1 total recoverable seleniuman arbitrary analyticalterm relating to the recoverable forms of selenium that aredeterminable by the digestion pro
10、cedures included in these testmethods.4. Significance and Use4.1 In most natural waters selenium concentrations seldomexceed 10 g/L. However, the runoff from certain types ofseleniferous soils at various times of the year can produceconcentrations as high as several hundred micrograms per litre.Addi
11、tionally, industrial contamination can be a significantsource of selenium in rivers and streams.4.2 High concentrations of selenium in drinking water havebeen suspected of being toxic to animal life. Selenium is apriority pollutant and all public water agencies are required tomonitor its concentrati
12、on.4.3 These test methods determine the dominant species ofselenium reportedly found in most natural and wastewaters,including selenities, selenates, and organo-selenium com-pounds.5. Purity of Reagents5.1 Reagent grade chemicals shall be used in all tests.Unless otherwise indicated, it is intended
13、that all reagents shallconform to the specifications of the Committee on AnalyticalReagents of the American Chemical Society, where such1These test methods are under the jurisdiction of ASTM Committee D19 onWater and are the direct responsibility of Subcommittee D19.05 on InorganicConstituents in Wa
14、ter.Current edition approved June 10, 2003. Published July 2003. Originallyapproved in 1984. Last previous edition approved in 1998 as D 3859 98.2Lansford, M., McPherson, E. M., and Fishman, M. J., Atomic AbsorptionNewsletter, Vol 13(4), 1974, pp. 103105. Pollack, E. N., and West, S. J., AtomicAbsor
15、ption Newsletter, Vol 12(1), 1973, pp. 68.3Annual Book of ASTM Standards, Vol 11.01.4Annual Book of ASTM Standards, Vol 11.02.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United
16、States.specifications are available.5Other grades may be used, pro-vided it is ascertained that the reagent is of sufficiently highpurity to permit its use without lessening the accuracy of thedetermination.5.2 Purity of Water Unless otherwise indicated, referenceto water shall be understood to mean
17、 reagent water conformingto Specification D 1193, Type I. Other reagent water types maybe used provided it is first ascertained that the water is ofsufficiently high purity to permit its use without adverselyaffecting the bias and precision of the test method. Type IIwater was specified at the time
18、of round robin testing of thistest method.6. Sampling6.1 Collect the samples in accordance with PracticesD 3370. Take the samples in acid-washed TFE-fluorocarbon orglass bottles. Other types of bottles may be used for sampling,but should be checked for selenium absorption. The holdingtime for the sa
19、mples may be calculated in accordance withPractice D 4841.6.2 When determining only dissolved selenium, filter thesample through a 0.45-m membrane filter as soon as possibleafter sampling. Add HNO3to the filtrate to bring the pH to2.0.6.3 When determining total recoverable selenium, addHNO3to the un
20、filtered sample to a pH of 2.0.TEST METHOD AGASEOUS HYDRIDE AAS7. Scope7.1 This test method covers the determination of dissolvedand total recoverable selenium in the range from 1 to 20 g/L.The range may be extended by decreasing the sample size ordiluting the original sample.7.2 This test method ha
21、s been used successfully withreagent water, natural water, wastewater, and brines. Theinformation on precision may not apply to waters of othermatrices.8. Summary of Test Method8.1 The determination consists of the conversion of sele-nium in its various forms to gaseous selenium hydride (hydro-gen s
22、elenide), with the subsequent analysis of the gas by flameAAS.8.1.1 The conversion consists of (a) decomposition andoxidation to selenium (VI), (b) reduction to selenium (IV), and(c) final reduction to selenium hydride.8.1.2 The absorbance is determined at 196.0 nm in ahydrogen-argon (air-entrained)
23、 flame.8.2 Sample concentrations are obtained directly from asimple concentration versus absorbance calibration curve.8.3 Total recoverable selenium is determined by treating theentire sample as the procedure indicates, and the dissolvedselenium is determined by treating the filtrate after the sampl
24、eis filtered through a 0.45-m membrane filter.9. Interferences9.1 Mercury and arsenic at concentrations greater than 500g/L and greater than 100 g/L, respectively, may inhibit theformation of selenium hydride.10. Apparatus10.1 An apparatus similar to that depicted in Fig. 1, with thecomponents speci
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD38592003STANDARDTESTMETHODSFORSELENIUMINWATER 水中 含量 标准 测试 方法 PDF

链接地址:http://www.mydoc123.com/p-515653.html