ASTM D3828-2007a Standard Test Methods for Flash Point by Small Scale Closed Cup Tester《用小刻度闭杯试验器测定闪点的标准试验方法》.pdf
《ASTM D3828-2007a Standard Test Methods for Flash Point by Small Scale Closed Cup Tester《用小刻度闭杯试验器测定闪点的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3828-2007a Standard Test Methods for Flash Point by Small Scale Closed Cup Tester《用小刻度闭杯试验器测定闪点的标准试验方法》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3828 07aDesignations: 523/05 and 524/05An American National StandardStandard Test Methods forFlash Point by Small Scale Closed Cup Tester1This standard is issued under the fixed designation D 3828; the number immediately following the designation indicates the year oforiginal adoption
2、 or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.INTROD
3、UCTIONThe flash point method is generally used for testing a sample at a specific temperature. At a settemperature, the specimen being tested and the airvapor mixture above it are close to thermalequilibrium. Test methods for other flash point equipment operated at a specific temperature aredescribe
4、d in Test Method D 3941.Flash point values are a function of the apparatus design, the condition of the apparatus used, andthe operational procedure carried out. Flash point can therefore only be defined in terms of a standardtest method, and no general valid correlation can be guaranteed between re
5、sults obtained by differenttest methods, or with test apparatus different from that specified.1. Scope*1.1 These test methods cover procedures for the determina-tion of the flash point by a small scale closed tester. Theprocedures may be used to determine the actual flash pointtemperature of a sampl
6、e or whether a product will or will notflash at a specified temperature (flash/no flash). When used inconjunction with an electronic thermal flash detector, these testmethods are also suitable for flash point tests on fatty acidmethyl esters (FAME).1.2 The values stated in SI units are to be regarde
7、d as thestandard. The values given in parentheses are for informationonly.1.3 This standard should be used to measure and describethe properties of materials, products, or assemblies in responseto heat and flame under controlled laboratory conditions andshould not be used to describe or appraise the
8、 fire hazard orfire risk of materials, products, or assemblies under actual fireconditions. However, results of this test may be used aselements of a fire risk assessment which takes into account allof the factors which are pertinent to an assessment of the firehazard of a particular end use.1.4 Thi
9、s standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Warning statementsapp
10、ear throughout. See also the Material Safety Data Sheets forthe product being tested.2. Referenced Documents2.1 ASTM Standards:2D 3941 Test Method for Flash Point by the EquilibriumMethod With a Closed-Cup ApparatusD 6299 Practice for Applying Statistical Quality AssuranceTechniques to Evaluate Anal
11、ytical Measurement SystemPerformance2.2 ISO Standards:3Guide 34 Quality Systems Guidelines for the Production ofReference MaterialsGuide 35 Certification of Reference MaterialsGeneraland Statistical PrinciplesEN ISO 3679 Determination of flashpoint with closed cupequilibrium methodEN ISO 3680 Determ
12、ination of flashpoint with closed cupequilibrium method1These test methods are under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.08.0B on Flammability.Current edition approved July 15, 2007. Published August 2007. Ori
13、ginallyapproved in 1979. Last previous edition approved in 2007 as D 382807.This is also a standard(s) of the Energy Institute issued under the fixeddesignations IP 523 and IP 524 (originally designated IP 303). The final numberindicates the year of last revision. These test methods were originally
14、adopted as ajoint ASTM-IP standard in 1979.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Am
15、erican National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3. Terminology3.1 Definitions:
16、3.1.1 equilibriumthe vapor above the liquid (specimen)and the liquid in a flash point apparatus specimen cup are at thesame temperature at the time the ignition source is applied.3.1.1.1 DiscussionThis condition may not be fullyachieved in practice. Although the temperature pattern is inequilibrium,
17、 the temperature is not uniform throughout thespecimen cup because of the contrast between the hot liquidtest specimen and the cooler lid and shutter.3.1.2 flash pointthe lowest temperature corrected to apressure of 760 mm Hg (101.3 kPa) at which application of atest flame causes the vapors of a spe
18、cimen of the sample toignite under specified conditions of test.3.1.2.1 DiscussionThe specimen is deemed to haveflashed when a flame appears and instantaneously propagatesitself over the surface of the specimen.3.1.2.2 DiscussionOccasionally, particularly near the ac-tual flash point, application of
19、 the test flame will cause a bluehalo or an enlarged flame; this is not a flash and should beignored.4. Summary of Test Method4.1 Method AFlash/No Flash TestA specimen of asample is introduced by a syringe into the cup of the selectedapparatus that is set and maintained at the specified tempera-ture
20、. After a specific time a test flame is applied and anobservation made as to whether or not a flash occurred.4.2 Method BFinite (or Actual) Flash Point:4.2.1 A specimen of a sample is introduced into the cup ofthe selected apparatus that is maintained at the expected flashpoint. After a specified ti
21、me a test flame is applied and theobservation made whether or not a flash occurred.4.2.2 The specimen is removed from the cup, the cupcleaned, and the cup temperature adjusted 5C (9F) lower orhigher depending on whether or not a flash occurred previ-ously. A fresh specimen is introduced and tested.
22、This proce-dure is repeated until the flash point is established within 5C(9F).4.2.3 The procedure is then repeated at 1C (2F) intervalsuntil the flash point is determined to the nearest 1C (2F).4.2.4 If improved accuracy is desired the procedure isrepeated at 0.5C (1F) intervals until the flash poi
23、nt isdetermined to the nearest 0.5C (1F).5. Significance and Use5.1 Flash point measures the response of the specimen ofthe sample to heat and flame under controlled laboratoryconditions. It is only one of a number of properties that must beconsidered in assessing the overall flammability hazard of
24、amaterial.5.2 Flash point is used in shipping and safety regulations todefine flammable and combustible materials and classify them.One should consult the particular regulation involved forprecise definitions of these classes.5.3 Flash point can indicate the possible presence of highlyvolatile and f
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD38282007ASTANDARDTESTMETHODSFORFLASHPOINTBYSMALLSCALECLOSEDCUPTESTER 刻度 试验 测定 闪点 标准 方法 PDF

链接地址:http://www.mydoc123.com/p-515573.html