1、Designation: D 3811/D 3811M 96 (Reapproved 2006)Standard Test Method forUnwind Force of Pressure-Sensitive Tapes1This standard is issued under the fixed designation D 3811/D 3811M; the number immediately following the designation indicates theyear of original adoption or, in the case of revision, th
2、e year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test method covers on
3、e procedure for determiningthe force required to unwind a roll of pressure-sensitive tape.1.2 The values stated in either SI or inch-pound units are tobe regarded separately as standard. The values stated in eachsystem may not be exact equivalents; therefore, each systemmust be used independently, w
4、ithout combining values in anyway.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limita
5、tions prior to use.2. Referenced Documents2.1 ASTM Standards:2D 996 Terminology of Packaging and Distribution Environ-mentsD 3715/D 3715M Practice for Quality Assurance ofPressure-Sensitive TapesD 4332 Practice for Conditioning Containers, Packages, orPackaging Components for TestingE 122 Practice f
6、or Calculating Sample Size to Estimate,With a Specified Tolerable Error, the Average for aCharacteristic of a Lot or Process3. Terminology3.1 DefinitionsGeneral terms in this test method aredefined in Terminology D 996.4. Summary of Test Method4.1 The sample roll of tape is placed on a free-turnings
7、pindle held in a CRE (constant-rate-of-extension) tensiontester. While the crosshead is moved at a specified rate, themaximum force measured during unwinding of approximately150 mm 6 in. of tape is taken as the unwind force.5. Significance and Use5.1 This procedure simulates hand and machine unwindi
8、ngof tape at low rates. The force required for unwinding at lowrates is a function of rate.At some rate (expected to be differentfor each construction type and manufacturer) there occurs aninversion of the response. The rate for this test method does notallow for comparisons of different tapes that
9、will be unwoundat high rates.5.2 This procedure can be used to indicate satisfactionwhere a specification for unwind, either maximum or mini-mum, is established and when the responses referred to in 5.1are taken into consideration.6. Apparatus6.1 Unwind Force TesterA CRE tension tester shall beused.
10、 The tester shall have two clamps with centers in the sameplane, parallel with the direction of motion of the stressingclamp, and so aligned that they will hold the specimen whollyin the same plane; a means of moving the stressing clamp at auniform rate of 5 6 0.2 mm/s 12.0 6 0.5 in./min; and anauto
11、graphic device for recording load. The instrument shall becalibrated to an accuracy of 0.5 % full scale. The scale rangeused for any test shall be such that the mean test level fallswithin 20 to 50 % of full scale.6.2 Free-Turning Spindle,3sized to fit snugly inside thesample tape core, with its axi
12、s horizontally supported in aframe that can be held in the clamp on the crosshead of theunwind tester that is not supporting the load cell.7. Sampling7.1 Acceptance SamplingSampling shall be in accordancewith Practice D 3715/D 3715M.7.2 Sampling for Other PurposesThe sampling and num-ber of test spe
13、cimens depends on the purpose of the testing.1This test method is under the jurisdiction of ASTM Committee D10 onPackaging and is the direct responsibility of Subcommittee D10.14 on Tape andLabels.Current edition approved April 1, 2006. Published April 2006. Originallyapproved in 1979. Last previous
14、 edition approved in 2001 as D 3811/D 3811M 96 (2001).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The so
15、le source of supply of the apparatus known to the committee at this timeis Chemsultants International, 9349 Hamilton Dr., Mentor, OH 440611118. If youare aware of alternative suppliers, please provide this information to ASTMInternational Headquarters. Your comments will receive careful consideratio
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD3811D3811M19962006STANDARDTESTMETHODFORUNWINDFORCEOFPRESSURESENSITIVETAPES 胶纸 带解舒力 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-515552.html