ASTM D3806-1998(2004) Standard Test Method of Small-Scale Evaluation of Fire-Retardant Paints (2-Foot Tunnel Method)《小规模评价阻燃涂料的标准试验方法(2英尺通道法)》.pdf
《ASTM D3806-1998(2004) Standard Test Method of Small-Scale Evaluation of Fire-Retardant Paints (2-Foot Tunnel Method)《小规模评价阻燃涂料的标准试验方法(2英尺通道法)》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3806-1998(2004) Standard Test Method of Small-Scale Evaluation of Fire-Retardant Paints (2-Foot Tunnel Method)《小规模评价阻燃涂料的标准试验方法(2英尺通道法)》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3806 98 (Reapproved 2004)Standard Test Method ofSmall-Scale Evaluation of Fire-Retardant Paints (2-FootTunnel Method)1This standard is issued under the fixed designation D 3806; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method determines the protection a coatingaffords its substrate, and the comparative
3、burning characteris-tics of coatings by evaluating the flame spread over the surfacewhen ignited under controlled conditions in a small tunnel.This establishes a basis for comparing surface-burning charac-teristics of different coatings without specific consideration ofall the end-use parameters tha
4、t might affect surface-burningcharacteristics under actual fire conditions.1.2 In addition to the experimental flamespread rate, theweight of panel consumed, time of afterflaming and afterglow,char dimensions and index, and height of intumescence may bemeasured in this test. However, a relationship
5、should not bepresumed among these measurements.1.3 This standard should be used to measure and describethe properties of materials, products, or assemblies in responseto heat and flame under controlled laboratory conditions, andshould not be used to describe or appraise the fire hazard or firerisk o
6、f materials, products, or assemblies under actual fireconditions. However, results of this test may be used aselements of a fire risk assessment which takes into account allof the factors which are pertinent to an assessment of the firehazard of a particular end use.1.4 The values stated in SI units
7、 are to be regarded as thestandard. The values given in parentheses are for informationonly.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health pract
8、ices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 220 Specification for Flat Asbestos-Cement SheetsD 344 Test Method for Relative Hiding Power of Paints bythe Visual Evaluation of BrushoutsD 1475 Test Method for Density of Liqui
9、d Coatings, Inks,and Related ProductsD 2196 Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational (Brookfield) Viscom-eterE 84 Test Method for Surface Burning Characteristics ofBuilding Materials2.2 Federal Standard:Fed. Spec. TT-V-119 Varnish, Spar, Phenolic Resin33. Sign
10、ificance and Use3.1 A number of laboratory procedures are used to evaluatethe effectiveness of fire-retardant and fire-resistant treatmentsand coatings. In general, these methods measure the threestages of fire development: (1) ignition; (2) flame spread (rateof growth of the fire); and (3) conflagr
11、ation extent. While allthree are of extreme importance, flame spread has beenrecognized as the main factor associated with testing fire-retardant coatings.3.2 Flame spread ratings based upon Test Method E 84 haveacquired common acceptance by regulatory agencies, but suchlarge-scale tests are seldom
12、practical during the developmentor modification of a fire-retardant coating.3.3 This test method provides the relative flame spread ofexperimental coatings using small test specimens. By calibrat-ing the 2-foot tunnel with Test Method E 84-rated fire-retardant1This test method is under the jurisdict
13、ion of ASTM Committee D01 on Paintand Related Coatings, Materials, and Applications and is the direct responsibility ofSubcommittee D01.22 on Health and Safety.Current edition approved June 1, 2004. Published June 2004. Originallyapproved in 1979. Last previous edition approved in 1998 as D 3806 98.
14、2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Standardization Documents Order Desk, DODSSP,
15、 Bldg. 4,Section D, 700 Robbins Ave., Philadelphia, PA 19111-5098.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.paint, results obtained by this test method should be indicativeof those obtained with a large specimen in the Test Met
16、hodE 84 tunnel.4. Apparatus4.1 Flame Tunnel4(see Fig. 1A)610-mm (two-foot) flametunnel consisting of asbestos-cement board mounted on an ironframework and supplied with natural gas fuel of uniformquality.4.1.1 The framework is constructed of 3 by 25 by 25-mm(18 by 1 by 1-in.) angle iron, the top of
17、which provides a 610by 100-mm (24 by 4-in.) specimen holder inclined at 28 to thehorizontal. The framework is mounted on a 250 by 610 by13-mm (10 by 24 by12-in.) steel base. The specimen holder iselevated 185 mm (738 in.) above the base at the lower (fire) endand 480 mm (1878 in.) at the upper (flue
18、) end.4.1.2 The fire end and sides of the tunnel are covered to theextent shown in Fig. 1, with 6-mm (14-in.) asbestos-cementboard5or 6-mm (14-in.) inorganic reinforced-cement board6attached to the inside of the angle iron framework. The openflue end and the cut-out sides allow a natural draft throu
19、gh thetunnel. Additional air access is provided by a 25mm (1in.)hole drilled in the cover at the fire end, centered and 115 mm(412 in.) above the base.4.1.3 An observation window made of a 50-mm (2-in.) widestrip of 3-mm (18-in.) polished heat-resistant sheet glass7islocated just below the specimen
20、holder, extending the fulllength of the tunnel, 610 mm (24 in.). This glass is marked byany appropriate method at 1-in. intervals from 4 to 22 in. A 560by 55 by 2-mm (22 by 214 by116-in.) sheet metal shield isattached above the window, slanting downwards at an angle of60 to shield the observation wi
21、ndow. The angle iron panelholder is notched along the bottom or supporting lip of theangle at 25-mm (1-in.) intervals to assist in the measurementsof the flame advance.NOTE 1A rule may also be mounted outside the observation windowto help measure the flame advancement.4.1.4 A 2.5-mm (332-in.) hole i
22、s drilled in the side of thespecimen holder immediately above the center of the burner toallow insertion of a thermocouple.4.1.5 The tunnel should be placed in an area as free fromdrafts as possible with facilities for removal or escape ofcombustion products. (Standard laboratory hood with forceddra
23、ft off during test.)4.2 Burner,8215 mm (8.5 in.) high with 40mm diameter,10-mm thick grid for use with natural gas. The burner is placed57 mm (214 in.) in from the fire end of the tunnel and 25 mm(1 in.) below the bottom side of the sample holder, that is, 30mm (118 in.) from the bottom of the speci
24、men. See Fig. 1.NOTE 2Artificial gas or liquid petroleum (LP) gas may be used, butburners designed for these types of gases must be used.4.3 Ignition Transformer, or other suitable ignition source,to generate a spark through a 2-mm (116-in.) Nichrome wire tothe burner barrel. The transformer is acti
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD380619982004STANDARDTESTMETHODOFSMALLSCALEEVALUATIONOFFIRERETARDANTPAINTS2FOOTTUNNELMETHOD 小规模 评价

链接地址:http://www.mydoc123.com/p-515545.html