ASTM D3760-2008 Standard Test Method for Analysis of Isopropylbenzene (Cumene) by Gas Chromatography《用气相色谱法分析异丙苯的标准试验方法》.pdf
《ASTM D3760-2008 Standard Test Method for Analysis of Isopropylbenzene (Cumene) by Gas Chromatography《用气相色谱法分析异丙苯的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3760-2008 Standard Test Method for Analysis of Isopropylbenzene (Cumene) by Gas Chromatography《用气相色谱法分析异丙苯的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3760 08Standard Test Method forAnalysis of Isopropylbenzene (Cumene) by GasChromatography1This standard is issued under the fixed designation D 3760; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last r
2、evision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the determination of the purityof isopropylbenzene (cumene) by gas chromatography.1.2 This test me
3、thod has been found applicable to themeasurement of impurities such as nonaromatic hydrocarbons,benzene, ethylbenzene, t-butylbenzene, n-propylbenzene,alpha-methylstyrene, sec-butylbenzene, and diisopropylben-zene, which are common to the manufacturing process ofisopropylbenzene. Limit of detection
4、for these impurities is 10mg/kg (see 5.1).1.3 In determining the conformance of the test results usingthis method to applicable specifications, results shall berounded off in accordance with the rounding-off method ofPractice E29.1.4 This standard does not purport to address all of thesafety concern
5、s, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardstatements, see Section 7.2. Referenced Documents2.1 ASTM Standar
6、ds:2D 3437 Practice for Sampling and Handling Liquid CyclicProductsD 6809 Guide for Quality Control and Quality AssuranceProcedures for Aromatic Hydrocarbons and Related Ma-terialsE29 Practice for Using Significant Digits in Test Data toDetermine Conformance with SpecificationsE 260 Practice for Pac
7、ked Column Gas ChromatographyE 355 Practice for Gas Chromatography Terms and Rela-tionshipsE 691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodE 1510 Practice for Installing Fused Silica Open TubularCapillary Columns in Gas Chromatographs2.2 Other Documen
8、t:OSHA Regulations, 29 CFR, paragraphs 1910.1000 and1910.120033. Summary of Test Method3.1 A known amount of internal standard is added to asample of isopropylbenzene. The prepared sample is mixedand analyzed by a gas chromatograph equipped with a flameionization detector (FID). The peak area of eac
9、h impurity andthe internal standard is measured and the amount of eachimpurity is calculated from the ratio of the peak area of theinternal standard versus the peak area of the impurity. Purity byGC (the isopropylbenzene content) is calculated by subtractingthe sum of the impurities found from 100.0
10、0. Results arereported in weight percent.4. Significance and Use4.1 This test method is suitable for setting specifications onthe materials referenced in 1.2 and for use as an internal qualitycontrol tool where isopropylbenzene is produced or is used ina manufacturing process. It may also be used in
11、 developmentor research work involving isopropylbenzene.4.2 This test method is useful in determining the purity ofisopropylbenzene with normal impurities present includingdiisopropylbenzenes. If extremely high boiling or unusualimpurities are present in the isopropylbenzene, this test methodwould n
12、ot necessarily detect them and the purity calculationwould be erroneous.4.3 Cumene hydroperoxide, if present, will yield decompo-sition products that will elute in the chromatogram therebygiving incorrect results.4.4 The nonaromatic hydrocarbons commonly present fromthe isopropylbenzene manufacturin
13、g process will interfere withthe determination of benzene when Column A in Table 1 isused.1This test method is under the jurisdiction of ASTM Committee D16 onAromatic Hydrocarbons and Related Chemicals and is the direct responsibility ofSubcommittee D16.07 on Styrene, Ethylbenzene and C9 and C10 Ato
14、maticHydrocarbons.Current edition approved Jan. 1, 2008. Published January 2008. Originallyapproved in 1979. Last previous edition approved in 2002 as D 3760 02e1.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book
15、 of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from U.S. Government Printing Office Superintendent of Documents,732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20401, http:/www.access.gpo.gov.1*A Summary of Changes section appe
16、ars at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.5 The internal standard must be sufficiently resolved fromany impurity and the isopropylbenzene peak.5. Apparatus5.1 Gas ChromatographAny instrument hav
17、ing a flameionization detector that can be operated at the conditions givenin Table 1. The system should have sufficient sensitivity toobtain a minimum peak height response for 10 mg/kgn-butylbenzene of twice the height of the signal backgroundnoise.5.2 ColumnsThe choice of column is based on resolu
18、tionrequirements. Any column may be used that is capable ofresolving all significant impurities from isopropylbenzene andfrom the internal standard. The columns described in Table 1have been used successfully.5.3 RecorderElectronic integration is recommended.6. Reagents and Materials6.1 Purity of Re
19、agentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,where such specifications are available.4Other grades may beused, provide
20、d it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.6.1.1 Internal StandardNormal Butylbenzene (nBB) isthe recommended internal standard of choice. Other com-pounds may be found acceptable provided they meet th
21、ecriteria as defined in 4.5 and 6.1.6.2 Carrier GasChromatographic grade helium or hydro-gen is recommended.6.3 Compressed AirChromatographic grade.6.4 HydrogenHigh purity.7. Hazards7.1 Consult current OSHA regulations and suppliers Mate-rial Safety Data Sheets on handling materials listed in this t
22、estmethod.8. Sampling and Handling8.1 Sample the material in accordance with PracticeD 3437.9. Preparation of Apparatus9.1 Follow manufacturers instructions for mounting andconditioning the column into the chromatograph and adjustingthe instrument to the conditions described in Table 1 allowingsuffi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD37602008STANDARDTESTMETHODFORANALYSISOFISOPROPYLBENZENECUMENEBYGASCHROMATOGRAPHY 用气相 色谱 分析 异丙苯 标准

链接地址:http://www.mydoc123.com/p-515425.html