ASTM D3730-2003 Standard Guide for Testing High-Performance Interior Architectural Wall Coatings《高性能结构内墙面饰层试验的标准指南》.pdf
《ASTM D3730-2003 Standard Guide for Testing High-Performance Interior Architectural Wall Coatings《高性能结构内墙面饰层试验的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3730-2003 Standard Guide for Testing High-Performance Interior Architectural Wall Coatings《高性能结构内墙面饰层试验的标准指南》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3730 03Standard Guide forTesting High-Performance Interior Architectural WallCoatings1This standard is issued under the fixed designation D 3730; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revis
2、ion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide covers the selection and use of test methodsfor high-performance interior architectural wall coatings(HIPAC) that di
3、ffer from more conventional coatings by beingtougher, more stain-resistant, more abrasion-resistant and,ordinarily, designed to be applied to wall surfaces of steel,masonry (poured concrete, concrete block, or cinder block),and plaster or gypsum wallboard. The tests that are listed inTables 1 and 2
4、are designed to measure performance proper-ties. These tests may not all be required for each HIPACsystem. Selection of the test methods to be followed must begoverned by experience and the requirements in each indi-vidual case, together with agreement between the purchaserand the seller.1.2 High-pe
5、rformance architectural coatings are tough,extra-durable organic coating systems that are applied as acontinuous (seamless) film and cure to a hard finish. The finishcan be high gloss, semigloss, or low gloss as desired. Thesecoatings are resistant to persistent heat, humidity, abrasion,staining, ch
6、emicals, and fungus growth. They are used in areaswhere humidity, wear, or unusual chemical resistance require-ments, particularly to soiling, are required and where strongdetergents are used to maintain sanitary conditions. Halls andstairways in public buildings, lavatories, stall showers, lockerar
7、eas, animal pens, and biological laboratories are typicalapplications. In addition, food processing plants, dairies, res-taurants, schools, and transport terminals frequently useHIPAC systems. These are effective in many areas of buildinginteriors compared with tile and are of low materials andmaint
8、enance costs. They are used as a complete system only asrecommended by the manufacturer since the individual coats ina system are formulated to be compatible with each other.HIPAC systems should be applied only to properly preparedsurfaces such as steel or masonry, including cinder blocks andcement
9、blocks. They can be applied over plaster and gypsumwallboard. Ordinarily, a prime or fill coat, if required, is part ofthe system.1.3 While they are excellent for walls, HIPAC are notusually intended for ceilings and floors. They would notordinarily be used in homes, although parents with smallchild
10、ren might want to use HIPAC coatings on some walls.1.4 The types of resin ordinarily used are the following:epoxy-polyamide, two-package; polyester-epoxy, two-package; polyurethane, one-package or two-package. How-ever, other resin types are not excluded provided they can meetthe requirements (perfo
11、rmance specifications) laid down by thepurchaser.1.5 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibil
12、ity of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For a specifichazard statement, see the note in 7.6.2. Referenced Documents2.1 ASTM Standards:D 16 Terminology for Paint, Related Coatings,
13、Materialsand Applications2D 93 Test Methods for Flash Point by Pensky-MartensClosed Cup Tester3D 154 Guide for Testing Varnishes4D 185 Test Methods for Coarse Particles in Pigments,Pastes, and Paints4D 344 Test Method for Relative Hiding Power of Paints bythe Visual Evaluation of Brushouts2D 523 Tes
14、t Method for Specular Gloss2D 562 Test Method for Consistency of Paints MeasruingKrebs Unit (KU) Viscosity Using a Stormer-Type Viscom-eter2D 869 Test Method for Evaluating Degree of Settling ofPaint51This guide is under the jurisdiction of ASTM Committee D01 on Paint andRelated Coatings, Materials,
15、 and Applications and is the direct responsibility ofSubcommittee D01.42 on Architectural Coatings.Current edition approved May 10, 2003. Published June 2003. Originallyapproved in 1978. Last previous edition approved in 1998 as D 3730 98.2Annual Book of ASTM Standards, Vol 06.01.3Annual Book of AST
16、M Standards, Vol 05.01.4Annual Book of ASTM Standards, Vol 06.03.5Annual Book of ASTM Standards, Vol 06.02.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.D 1005 Test Method for Measurement of Dry-Film Thick-ness of Organic Coatings
17、Using Micrometers2D 1186 Test Methods for Nondestructive Measurement ofDry Film Thickness of Nonmagnetic Coatings Applied toa Ferrous Base2D 1210 Test Method for Fineness of Dispersion of Pigment-Vehicle Systems by Hegman-Type Gage2D 1211 Test Method for Temperature-Change Resistance ofClear Nitroce
18、llulose Lacquer Films Applied to Wood5D 1212 Test Methods for Measurement of Wet Film Thick-ness of Organic Coatings2D 1296 Test Method for Odor of Volatile Solvents andDiluents6D 1308 Test Method for Effect of Household Chemicals onClear and Pigmented Organic Finishes5D 1400 Test Method for Nondest
19、ructive Measurement ofDry Film Thickness of Nonconductive Coatings Applied toa Nonferrous Metal Base2D 1475 Test Method for Density of Liquid Coatings, Inks,6Annual Book of ASTM Standards, Vol 06.04.TABLE 1 List of Standards in Sectional OrderProperty(or Related Test)SectionASTMTestMethodFederalTest
20、MethodStandardNo. 141Sampling: 6.2 D 3925 .Liquid Paint Properties:Skinning 7.1 D 154Condition in container 7.2 . 3011Coarse particles and foreign matter 7.3 D 185Density or weight per gallon 7.4 D 1475Fineness of dispersion 7.5 D 1210Flash point 7.7 D 93, D 3278Dilution stability 7.8 . 4203Volatile
21、 content 7.9 D 2369 .Free diisocyanate content 7.10 D 3432 .Package stability 7.11Heat stability 7.11.1 D 1849Settling 7.11.2 D 869Coating Application and Film Formation:Application properties 8.1 . 4541Brush application 8.1.1 . 2141Brush drag 8.1.1.1 D 4958 .Roller application 8.1.2 . 2112Roller sp
22、atter 8.1.2.1 D 4707 .Spray application 8.1.3 . 2131Rheological properties 8.2 . .Consistency (low-shear viscosity) 8.2.1 D 562 .Rheological properties of non-Newtonian liquids8.2.2 D 2196, D 4287 .Sag resistance 8.2.3 D 4400 .Leveling properties 8.2.4 D 4062 .Curing properties 8.3 . .Wet-film thick
23、ness 8.4 D 1212 .Touch-up uniformity 8.5 D 3928Appearance of Dry Coating:Color appearance 9.1.1 . .Color differences by visual comparison 9.1.2 D 1729 .Color differences usinginstrumental measurements9.1.3 D 2244 .Directional reflectance 9.2 E 1347 .Gloss, 60 9.3 D 523 .Hiding power 9.4 D 344, D 280
24、5 .Yellowness index 9.5 E 313Properties of Dry Film:Abrasion resistance 10.1 D 4060 .Adhesion 10.2 D 4541 .Impact resistance 10.3 D 2794 .Chemical resistance 10.4 D 1308 .Washability and cleansability 10.5 . .Washability 10.5.1 D 2486, D 4213 .Cleansability 10.5.2 D 3450, D 4828 .Mildew resistance 1
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD37302003STANDARDGUIDEFORTESTINGHIGHPERFORMANCEINTERIORARCHITECTURALWALLCOATINGS 性能 结构 墙面 试验 标准 指南

链接地址:http://www.mydoc123.com/p-515354.html