ASTM D3700-2007 Standard Practice for Obtaining LPG Samples Using a Floating Piston Cylinder《用浮动活塞柱获取液化石油气(LPG)样品的标准实施规程》.pdf
《ASTM D3700-2007 Standard Practice for Obtaining LPG Samples Using a Floating Piston Cylinder《用浮动活塞柱获取液化石油气(LPG)样品的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3700-2007 Standard Practice for Obtaining LPG Samples Using a Floating Piston Cylinder《用浮动活塞柱获取液化石油气(LPG)样品的标准实施规程》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3700 07An American National StandardStandard Practice forObtaining LPG Samples Using a Floating Piston Cylinder1This standard is issued under the fixed designation D 3700; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revisi
2、on, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This practice covers the equipment and procedures forobtaining a representative sample of specificat
3、ion liquefiedpetroleum gas (LPG), such as specified in SpecificationD 1835, GPA 2140, and comparable international standards. Itmay also be used for other natural gas liquid (NGL) productsthat are normally single phase (NGL mix, field butane, and soforth), defined in other industry specifications or
4、 contractualagreements.1.2 This practice is not intended for non-specification prod-ucts that contain significant quantities of undissolved gases(N2,CO2), free water or other separated phases, such as raw orunprocessed gas/liquids mixtures and related materials. Thesame equipment can be used for the
5、se purposes, but additionalprecautions are generally needed to obtain representativesamples of multi-phase products (see Appendix X1).1.3 This practice includes recommendations for the locationof a sample point in a line or vessel. It is the responsibility ofthe user to ensure that the sampling poin
6、t is located so as toobtain a representative sample.1.4 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsi
7、bility of the user of this standard to establish appro-priate safety and health practices, and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1265 Practice for Sampling Liquefied Petroleum (LP)Gases, Manual MethodD 1835 Specification
8、for Liquefied Petroleum (LP) Gases2.2 GPA Standards:3GPA 2174 Obtaining Liquid Hydrocarbon Samples forAnalysis by Gas ChromatographyGPA 2140 Liquefied Petroleum Gas Specifications and TestMethods3. Terminology3.1 Definitions:3.1.1 floating piston cylinder (FPC)a high pressuresample container, with a
9、 free floating internal piston thateffectively divides the container into two separate compart-ments.3.1.2 maximum fill density (reduced fill density)the vol-ume of a container occupied by the sample, usually expressedas a percentage of the total capacity.4. Summary of Practice4.1 A liquid LPG sampl
10、e is transferred under pressure froma sample point to a floating piston cylinder. The floating pistoncylinder (FPC) is designed to collect liquid samples with novaporization by displacing a piston against a pressurizing fluid(usually an inert gas). The piston serves as a physical barrierbetween the
11、sample and the pressurizing fluid, at the samplingpressure. The position of the piston at the end of samplingindicates the percent fill of the sample cylinder.4.2 It is the responsibility of the user of this practice tolocate the sample point at a suitable location where the productbeing sampled is
12、a representative, single phase, homogeneousliquid.5. Significance and Use5.1 This practice allows the collection of a representativesample of LPG that may contain trace volatile componentssuch as methane, nitrogen, and ethane. Sampling by PracticeD 1265 may result in a small, but predictable loss of
13、 theselighter components. Practice D 1265 is suitable for collectingsamples for routine specification testing, as the small loss oflight components is not significant under Specification D 1835specification requirements. Practice D 3700 is recommendedwhenever highly accurate determination of light c
14、omponents is1This practice is under the jurisdiction of ASTM Committee D02 on PetroleumProducts and Lubricants and is the direct responsibility of Subcommittee D02.H0 onLiquefied Petroleum Gas.Current edition approved Feb. 15, 2007. Published March 2007. Originallyapproved in 1978. Last previous edi
15、tion approved in 2001 as D 370001.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Gas Process
16、ors Association (GPA), 6526 E. 60th St., Tulsa, OK74145.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.required. For example, composition determined on samplescollect
17、ed according to Practice D 3700 may be used to estab-lish product value of NGL mixtures (see Appendix X1).6. Interferences6.1 An interference in a sampling procedure is anythingwhich compromises the integrity of the sample.6.2 Sample point location can give a non-representativesample due to solid or
18、 liquid contaminants, two phases, storagetank stratification, and so forth.6.3 Reactivity of steel surfaces can remove or chemicallyalter trace reactive components such as H2S, COS, andmercaptan.6.4 A lubricant that is soluble in LPG can contaminate thesample.6.5 Pre-charge gas can leak into the sam
19、ple due to worn ordamaged seals or poor surface finish (see 8.1).6.5.1 Consult manufacturers guidelines for suitable proce-dure to verify a leak-free cylinder, such as pressure testing eachside of the cylinder. It is also possible to analyze the sample forinert gas, or the inert gas for hydrocarbon,
20、 to detect leakage ineither direction.6.6 Failure to flush sample lines and dead volumes canresult in contaminants in samples.6.7 Sampling from stratified tanks, dead zones in flowingsystems, or inappropriate time periods in composite samplingsystems will result in non-representative samples.7. Appa
21、ratus7.1 Floating Piston Cylinder (FPC):7.1.1 Construction, typically fabricated from corrosion re-sistant 316 stainless steel, in accordance with the pressurevessel certification requirements in the jurisdictions in which itis to be used, and through which it will be transported.Protective internal
22、 coatings or surface treatments are accept-able provided that they do not adversely affect the freemovement of the piston, or effectiveness of the seals (see Fig.1).NOTE 1At present, there is no international approval process forpressure cylinders. Cylinders require appropriate approval in each juri
23、s-diction in which they are used or transported.7.1.2 Volume of Sample, as required by the tests to beperformed, typically 400 mL (that is, 80 % of 500 mL samplecylinder at 15C).NOTE 2For safe handling of these cylinders under extremes ofproduct or ambient temperatures, or both, the user must consid
24、er theeffects of thermal expansion on the volume of product in the cylinder. Forexample, if a very cold product is sampled, 40C (40F) for example,the cylinder should be expected to warm considerably before analysis isperformed during transport and in the laboratory. During summer months,the temperat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD37002007STANDARDPRACTICEFOROBTAININGLPGSAMPLESUSINGAFLOATINGPISTONCYLINDER 浮动 活塞 获取 液化 石油气 LPG 样品

链接地址:http://www.mydoc123.com/p-515298.html