ASTM D3686-2008 Standard Practice for Sampling Atmospheres to Collect Organic Compound Vapors (Activated Charcoal Tube Adsorption Method)《用收集有机化合物蒸气进行大气取样的标准方法》.pdf
《ASTM D3686-2008 Standard Practice for Sampling Atmospheres to Collect Organic Compound Vapors (Activated Charcoal Tube Adsorption Method)《用收集有机化合物蒸气进行大气取样的标准方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3686-2008 Standard Practice for Sampling Atmospheres to Collect Organic Compound Vapors (Activated Charcoal Tube Adsorption Method)《用收集有机化合物蒸气进行大气取样的标准方法》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3686 08Standard Practice forSampling Atmospheres to Collect Organic CompoundVapors (Activated Charcoal Tube Adsorption Method)1This standard is issued under the fixed designation D 3686; the number immediately following the designation indicates the year oforiginal adoption or, in the
2、 case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers a method for the sampling ofatmospheres to determine the presence
3、of certain organicvapors by means of adsorption on activated charcoal using acharcoal tube and a small portable sampling pump worn by aworker. A list of some of the organic chemical vapors that canbe sampled by this practice is provided in Annex A1. This listis presented as an information guide and
4、should not beconsidered as absolute or complete.1.2 This practice does not cover any method of samplingthat requires special impregnation of activated charcoal orother adsorption media.1.3 The values stated in SI units are to be regarded as thestandard.1.4 This standard does not purport to address a
5、ll of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. A specific safetyprecaution is given in 9.4.2. Referenced Doc
6、uments2.1 ASTM Standards:2D 1356 Terminology Relating to Sampling and Analysis ofAtmospheresD 3687 Practice for Analysis of Organic Compound VaporsCollected by the Activated Charcoal Tube AdsorptionMethodD 5337 Practice for Flow Rate Calibration of PersonalSampling Pumps2.2 NIOSH Standards:CDC-99-74
7、-45 Documentation of NIOSH Validation Tests3HSM-99-71-31 Personal Sampler Pump for CharcoalTubes; Final Report3NIOSH Manual of Analytical Methods, Fourth Edition42.3 OSHA Standards:29 CFR 1910 Code of Federal Regulations Relating to La-bor, Occupational Safety and Health Administration, De-partment
8、of Labor5OSHA Chemical Sampling Information6OSHA Sampling and Analytical Methods72.4 UK Health and Safety Executive:8Methods for Deter-mination of Hazardous Substances (MDHS)2.5 Berufsgenossenschaftliches Institut fr Arbeitsschulz(BGIA)9GESTIS Analytical Methods3. Terminology3.1 For definitions of t
9、erms used in this method, refer toTerminology D 1356.3.2 Activated charcoal refers to properly conditioned char-coal.4. Summary of Practice4.1 Air samples are collected for organic vapor analysis byaspirating air at a known rate and for an appropriate timethrough sampling tubes containing activated
10、charcoal.4.2 Instructions are given to enable assembly of charcoaltubes suitable for sampling purposes.4.3 Information on the correct use of the charcoal tubesampling device is presented.4.4 Practice D 3687 describes a practice for the analysis ofthese samples.1This practice is under the jurisdictio
11、n of ASTM Committee D22 on Air Qualityand is the direct responsibility of Subcommittee D22.04 on Workplace Air Quality.Current edition approved Dec. 15, 2008. Published January 2009. Originallyapproved in 1978. Last previous edition approved in 2001 as D 3686 - 95(2001)1.2For referenced ASTM standar
12、ds, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from National Technical Information Service (NTIS), 5285 PortRoyal Rd., Spring
13、field, VA 22161, http:/www.ntis.gov.4NIOSH Manual of Analytical Methods. http:/www.cdc.gov/niosh/nmam/5Available from U.S. Government Printing Office Superintendent of Documents,732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20401, http:/www.access.gpo.gov.6OSHA Chemical Sampling Information
14、. http:/osha.gov/dts/chemicalsampling/toc/toc_chemsamp.html7OSHA Sampling and Analytical Methods. http:/osha.gov/dts/sltc/methods/toc.html8Health Safety Executive. Methods for the Determination of Hazardous Sub-stances (MDHS) guidance. http:/www.hse.gov.uk/pubns/mdhs/index.htm#9Berufsgenossenschaftl
15、iches Institut fr Arbeitsschutz. GESTIS Analyticalmethods. http:/www.hvbg.de/e/bia/gestis/analytical_methods/index.html1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5. Significance and Use5.1 Promulgations by the U.S. Occupational
16、Safety andHealth Administration (OSHA) in 29 CFR 1910 1910.1000designate that certain organic compounds must not be presentin workplace atmospheres at concentrations above specificvalues.5.2 This practice, when used in conjunction with PracticeD 3687, will provide the needed accuracy and precision f
17、or thedetermination of airborne time-weighted average concentra-tions of many of the organic chemicals cited in CDC-99-74-45,HSM-99-71-31, NIOSH Manual of Analytical Methods,29 CFR 1910 1910.1000, OSHA Chemical Sampling Informa-tion, OSHA Sampling and Analytical Methods, HSE Methodsfor the Determina
18、tion of Hazardous Substances, and BGIAGETIS Analytical Methods.5.3 A partial list of chemicals for which this method isapplicable is given in Annex A1, along with their OSHApermissible exposure limits.6. Interferences6.1 Water mist and vapor can interfere with the collection oforganic compound vapor
19、s. Humidity greater than 60 % canreduce the adsorptive capacity of activated charcoal up to 50 %for some chemicals (1).10Presence of condensed water drop-lets in the sample tube will indicate a suspect sample.6.2 High levels of organic vapors can interfere by reducingthe amount of time a workplace c
20、an be sampled before thecharcoal sampler becomes saturated.7. Apparatus7.1 Charcoal Tube:7.1.1 A sampling tube consists of a length of glass tubingusually containing two sections of activated charcoal that areheld in place and separated by nonadsorbent material. The tubeis sealed at each end.7.1.1.1
21、 Sampling tubes are commercially available. Thetubes are usually divided into two sections with the frontsection containing 100 to 800 mg of activated charcoal and theback section containing 50 to 400 mg of activated charcoal.The 100/50-mg tube (2-4) and Fig. 1) is the one mostfrequently used, it co
22、nsists of a glass tube that is 70-mm long,6-mm outside diameter, 4-mm inside diameter, and containstwo sections of 20/40 mesh-activated coconut-shell charcoalseparated by a 2-mm section of urethane foam. The frontsection of 100 mg is retained by a plug of glass wool, and theback section of 50 mg is
23、retained by either a second 2-mmportion of urethane foam or by a plug of glass wool. Both endsof the tube are usually flame-sealed.NOTE 1Urethane foam is known to adsorb certain pesticides (5).Contaminated urethane foam should not be used for this practice.7.1.1.2 When it is desirable to sample high
24、ly volatilecompounds for extended periods, or at a high volume flow rate,a larger device capable of efficient collection can be used,provided the proportions of the tube and its charcoal contentsare scaled similarly to the base dimensions to provide nomi-nally the same linear flow rate and contact t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD36862008STANDARDPRACTICEFORSAMPLINGATMOSPHERESTOCOLLECTORGANICCOMPOUNDVAPORSACTIVATEDCHARCOALTUBEADSORPTIONMETHOD

链接地址:http://www.mydoc123.com/p-515265.html