ASTM D3633 D3633M-2012 Standard Test Method for Electrical Resistivity of Membrane-Pavement Systems《薄膜铺面系统电阻率的标准试验方法》.pdf
《ASTM D3633 D3633M-2012 Standard Test Method for Electrical Resistivity of Membrane-Pavement Systems《薄膜铺面系统电阻率的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3633 D3633M-2012 Standard Test Method for Electrical Resistivity of Membrane-Pavement Systems《薄膜铺面系统电阻率的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation:D363398(Reapproved 2006) Designation: D3633 12Standard Test Method forElectrical Resistivity of Membrane-Pavement Systems1This standard is issued under the fixed designation D3633; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the measurement of the electrical resistivity of water-barrier membrane-
3、pavement systems whenapplied to concrete bridge decks.1.2 Measurements shall be performed on the bituminous pavement surface covering the water-barrier membrane.1.3 This test method utilizes a measure of electrical resistance between the saturated top surface of the water-barrier membraneand the rei
4、nforcing steel embedded in the concrete bridge deck.1.4 The values measured represent the electrical resistance obtained with the equipment and procedures stated herein and donot necessarily agree or correlate with those using other equipment or procedures.1.5The values stated in SI units are to be
5、regarded as the standard.1.5 UnitsThe values stated in either SI units or inch-pound units are to be regarded separately as standard. The values statedin each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining valuesfrom the two systems ma
6、y result in nonconformance with the standard.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulat
7、orylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C670 Practice for Preparing Precision and Bias Statements for Test Methods for Construction MaterialsD3743 Terminology Relating to Bridge Deck and Substructure ProtectionD4071 Practice for Use of Portland Cement Concrete Bridge D
8、eck Water Barrier Membrane SystemsE105 Practice for Probability Sampling of Materials3. Terminology3.1 For definitions of terms used in this specification, refer to Terminology D3743.4. Significance and Use4.1 This test method for measuring the electrical resistivity of water-barrier membrane-paveme
9、nt systems may be interpretedto indicate the effectiveness of such systems.4.2 This test method is predicated on the fact that an electrical connection between the surface of the pavement and thereinforcing steel in the concrete pavement cannot be made through an impermeable water-barrier membrane.4
10、.3 This test method may be used for acceptance when the accepting agency specifies the minimum resistance value desired.5. Apparatus5.1 Ohmmeter, dc, 20 000 V/V rating connected to a double-pole, double-throw switch box or ac ohmmeter (switch box notrequired).NOTE 1When this test method is used for
11、acceptance, the accepting agency should specify the type of ohmmeter to be used.5.2 Insulated Wire, No. 18, Belden test probewire or equivalent. Two spools, minimum 38 m (125 ft). 125 ft.1This test method is under the jurisdiction of ASTM Committee D04 on Road and Paving Materials and is the direct
12、responsibility of Subcommittee D04.32 on Bridgesand Structures.Current edition approved Dec. 1, 2006. Published December 2006. Originally approved in 1977. Last previous edition approved in 1998 as D363398. DOI:10.1520/D3633-98R06.Current edition approved June 1, 2012. Published July 2012 . Original
13、ly approved in 1977. Last previous edition approved in 2006 as D3633 98(2006). DOI:10.1520/D3633-12.2For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Docu
14、ment Summary page on the ASTM website.1This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM
15、recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.3 Coppe
16、r Plate, 305 by 305 by 3.0 mm (1212 by 12 by18 in.),in., with the means for connecting the ohmmeter lead anda wooden handle approximately 1 m (39 in.)39 in. in length.5.4 Polyurethane Sponge, 305 by 305 by 13 mm (1212 by 12 by12 in.),in., to be attached to the copper plate with rubber bandsor other
17、suitable means. When assembled this apparatus is called the probe.5.5 Pressure Spray Can, 12-L (3-gal)3-gal capacity, with a hose and spray nozzle.6. Reagent6.1 A wetting agent which, when added to the water, will break the surface tension and promote the penetration of the waterthrough the bitumino
18、us pavement.NOTE 2An example of a wetting agent is a super-saturated solution of cupric sulfate crystals in warm water to which is added 19 mL/gal of DdioctylS sodium S sulfo-succinate (Tradename “Aerosol” OT Clear, 10 %). When ambient test site temperature is below 50F (10C),10C, add 15 % byvolume
19、of either isopropyl or denatured alcohol to prevent clouding of the wetting agent. Clouding of the wetting agent may inhibit penetration.7. Sampling7.1 Determine locations on the bridge deck to be tested by using either a grid pattern similar to that illustrated in Fig. 1 or bya random location syst
20、em, based upon Practice E105 or a similar method, that will ensure that the bridge deck area to be testedwill be adequately represented.8. Procedure8.1 Prepare the surface to be tested by removing all foreign material by sweeping or scraping, or both. Do not use water to clean.The surface mustshall
21、be dry and clean before testing.8.1.1 Locate the reinforcing steel with a pachometer. Drill with a rotary impact hammer at selected locations to expose thereinforcing steel to allow attachment of ohmmeter leads. Alternately, drill until the drill bit contacts the steel firmly to allowohmmeter lead a
22、ttachment.8.2 Uncoil an ample length of wire to reach all areas to be tested, attach the minus () jack of the ohmmeter to the reinforcingsteel and the plus ( + ) jack to the 305 by 305 by 3.0-mm (1212 by 12 by18-in.)-in. copper plate of the probe. Then saturate thesponge with water containing the we
23、tting agent.NOTE 3A direct connection from the ohmmeter to the top layer of reinforcing steel in the deck is desirable. However, if it is not practical to do this,the bridge railing, expansion joints, light standards, drainage scuppers, or other exposed steel, whichthat is known to have contact with
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD3633D3633M2012STANDARDTESTMETHODFORELECTRICALRESISTIVITYOFMEMBRANEPAVEMENTSYSTEMS 薄膜 铺面 系统 电阻率 标准

链接地址:http://www.mydoc123.com/p-515139.html