ASTM D3631-1999(2004) Standard Test Methods for Measuring Surface Atmospheric Pressure《测量地面大气压的标准试验方法》.pdf
《ASTM D3631-1999(2004) Standard Test Methods for Measuring Surface Atmospheric Pressure《测量地面大气压的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3631-1999(2004) Standard Test Methods for Measuring Surface Atmospheric Pressure《测量地面大气压的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3631 99 (Reapproved 2004)Standard Test Methods forMeasuring Surface Atmospheric Pressure1This standard is issued under the fixed designation D 3631; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last re
2、vision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 These methods cover the measurement of atmosphericpressure with two types of barometers: the Fortin-type mercu-rial baromete
3、r and the aneroid barometer.1.2 In the absence of abnormal perturbations, atmosphericpressure measured by these methods at a point is valideverywhere within a horizontal distance of 100 m and a verticaldistance of 0.5 m of the point.1.3 Atmospheric pressure decreases with increasing heightand varies
4、 with horizontal distance by 1 Pa/100 m or lessexcept in the event of catastrophic phenomena (for example,tornadoes). Therefore, extension of a known barometric pres-sure to another site beyond the spatial limits stated in 1.2 canbe accomplished by correction for height difference if thefollowing cr
5、iteria are met:1.3.1 The new site is within 2000 m laterally and 500 mvertically.1.3.2 The change of pressure during the previous 10 min hasbeen less than 20 Pa.The pressure, P2at Site 2 is a function of the known pressureP1at Site 1, the algebraic difference in height above sea level,h1 h2, and the
6、 average absolute temperature in the spacebetween. The functional relationship between P1and P2isshown in 10.2. The difference between P1and P2for each 1 mof difference between h1and h2is given in Table 1 and 10.4 forselected values of P1and average temperature.1.4 Atmospheric pressure varies with t
7、ime. These methodsprovide instantaneous values only.1.5 The values stated in SI units are to be regarded as thestandard.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-pr
8、iate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific safetyprecautionary statements are given in Section 7.2. Referenced Documents2.1 ASTM Standards:2D 1356 Terminology Relating to Sampling and Analysis ofAtmospheresD 3249 Practice for Ge
9、neral Ambient Air Analyzer Proce-duresIEEE/ASTM SI 10 Standard for Use of the InternationalSystem of Units (SI): The Modern Metric System3. Terminology3.1 Pressure for meteorological use has been expressed in anumber of unit systems including inches of mercury, millime-tres of mercury, millibars, an
10、d others less popular. Thesemethods will use only the International System of Units (SI), asdescribed in IEEE/ASTM SI 10.3.1.1 Much of the apparatus in use and being sold reads inother than SI units, so for the convenience of the user thefollowing conversion factors and error equivalents are given.3
11、.1.1.1 The standard for pressure (force per unit area) is thepascal (Pa).3.1.1.2 One standard atmosphere at standard gravity(9.80665 m/s2) is a pressure equivalent to:29.9213 in. Hg at 273.15 K760.000 mm Hg at 273.15 K1013.25 millibars14.6959 lbf/in.2101325 Pa or 101.325 kPa3.1.1.3 1 Pa is equivalen
12、t to:0.000295300 in. Hg at 273.15 K0.00750062 mm Hg at 273.15 K0.01000000 millibars0.000145037 lbf/in.20.000009869 standard atmospheres3.2 standard gravityas adopted by the International Com-mittee on Weights and Measures, an acceleration of 9.80665m/s2(see 10.1.3).1These test methods are under the
13、jurisdiction of ASTM Committee D22 onSampling and Analysis of Atmospheres and are the direct responsibility ofSubcommittee D22.11 on Meteorology.Current edition approved April 1, 2004. Published June 2004. Originallyapproved in 1977. Last previous edition approved in 1999 as D 3631 - 99.2For referen
14、ced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West C
15、onshohocken, PA 19428-2959, United States.3.3 The definitions of all other terms used in these methodscan be found in Terminology D 1356 and Practice D 3249.4. Summary of Methods4.1 The instantaneous atmospheric pressure is measuredwith two types of barometers.4.2 Method A utilizes a Fortin mercuria
16、l barometer. Themercury barometer has the advantage of being fundamental inconcept and direct in response. The disadvantages of themercury barometer are the more laborious reading procedurethan the aneroid barometer, and the need for temperaturecorrection.4.3 Method B utilizes an aneroid barometer.
17、The aneroidbarometer has the advantages of simplicity of reading, absenceof mercury, no need for temperature compensation by theobserver, and easy detection of trend of change. The maindisadvantages of the aneroid barometer are that it is notfundamental in concept as the mercury barometer, and itreq
18、uires calibration periodically against a mercury barometer.5. Significance and Use5.1 Atmospheric pressure is one of the basic variables usedby meteorologists to describe the state of the atmosphere.5.2 The measurement of atmospheric pressure is neededwhen differences from “standard” pressure condit
19、ions must beaccounted for in some scientific and engineering applicationsinvolving pressure dependent variables.5.3 These methods provide a means of measuring atmo-spheric pressure with the accuracy and precision comparable tothe accuracy and precision of measurements made by govern-mental meteorolo
20、gical agencies.6. Apparatus6.1 Fortin Barometer, which is a mercurial barometer con-sisting of a glass tube containing mercury with an adjustablecistern and an index pointer projecting downward from the roofof the cistern. The mercury level may be raised or lowered byturning an adjustment screw bene
21、ath the cistern.6.1.1 To provide acceptable measurements, the specifica-tions of 6.1.2-6.1.11 must be met.6.1.2 Maximum error at 100 000 Pa 6 30 Pa.6.1.2.1 Maximum error at any other pressure for a barom-eter whose range: (a) does not extend below 80 000 Pa 6 50Pa (b) extends below 80 000 Pa 6 80 Pa
22、.6.1.2.2 For a marine application the error at a point must notexceed 6 50 Pa.6.1.3 Difference between errors over an interval of 10 000Pa or less 6 30 Pa.6.1.4 Accuracy must not deteriorate by more than 6 50 Paover a period of a year.6.1.5 It must be transportable without loss of accuracy.6.1.6 A m
23、ercurial barometer must be able to operate atambient temperatures ranging from 253 to 333 K (20 to 60C)and must not be exposed to temperatures below 253 K(38C). It must be able to operate over ambient relativehumidities ranging from 0 to 100 %.6.1.7 A thermometer with a resolution of 0.11 K and apre
24、cision and accuracy of 0.05 K must be attached to the barrelof the barometer.6.1.8 The actual temperature for which the scale of amercury barometer is designed to give true readings (atstandard gravity) must be engraved on the barometer.6.1.9 If the evacuated volume above the mercury columncan be pu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD363119992004STANDARDTESTMETHODSFORMEASURINGSURFACEATMOSPHERICPRESSURE 测量 地面 大气压 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-515133.html