ASTM D3606-2010e1 Standard Test Method for Determination of Benzene and Toluene in Finished Motor and Aviation Gasoline by Gas Chromatography《采用气相色谱法测定成品发动机和航空汽油中苯和甲苯的标准试验方法》.pdf
《ASTM D3606-2010e1 Standard Test Method for Determination of Benzene and Toluene in Finished Motor and Aviation Gasoline by Gas Chromatography《采用气相色谱法测定成品发动机和航空汽油中苯和甲苯的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3606-2010e1 Standard Test Method for Determination of Benzene and Toluene in Finished Motor and Aviation Gasoline by Gas Chromatography《采用气相色谱法测定成品发动机和航空汽油中苯和甲苯的标准试验方法》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D3606 101Standard Test Method forDetermination of Benzene and Toluene in Finished Motorand Aviation Gasoline by Gas Chromatography1This standard is issued under the fixed designation D3606; the number immediately following the designation indicates the year oforiginal adoption or, in th
2、e case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTESubsection 1.3 and Note 7 were corrected editorially in April 2016.1. Scope*1.1 This test met
3、hod covers the determination of benzeneand toluene in finished motor and aviation gasolines by gaschromatography.1.2 Benzene can be determined between the levels of 0.1and 5 volume % and toluene can be determined between thelevels of 2 and 20 volume %.1.3 The precision for this test method was deter
4、mined usingconventional gasoline as well as gasolines containing oxygen-ates (ethers such as methyl tert-butyl ether, ethyl tert-butylether,tert-amyl methyl ether, and ethanol).1.4 Methanol may cause interference. Appendix X1 pro-vides an option for modifying the test method for analyzingsamples con
5、taining ethanol.1.5 The values stated in SI units are to be regarded asstandard. The values given in parentheses are for informationonly.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to e
6、stablish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D4057 Practice for Manual Sampling of Petroleum andPetroleum ProductsE694 Specification for Laboratory Glass Volumetric Appa-ratusE969
7、Specification for Glass Volumetric (Transfer) PipetsE1044 Specification for Glass Serological Pipets (GeneralPurpose and Kahn)E1293 Specification for Glass Measuring Pipets3. Summary of Test Method3.1 An internal standard, methyl ethyl ketone (MEK), isadded to the sample which is then introduced int
8、o a gaschromatograph equipped with two columns connected inseries. The sample passes first through a column packed with anonpolar phase such as dimethylpolysiloxane (8.1.1) whichseparates the components according to boiling point. Afteroctane has eluted, the flow through the nonpolar column isrevers
9、ed, flushing out the components heavier than octane. Theoctane and lighter components then pass through a columnpacked with a highly polar phase such as 1, 2, 3-tris(2-cyanoethoxy) propane (8.1.2) which separates the aromatic andnonaromatic compounds. The eluted components are detectedby a thermal c
10、onductivity detector. The detector response isrecorded, the peak areas are measured, and the concentration ofeach component is calculated with reference to the internalstandard.4. Significance and Use4.1 Benzene is classed as a toxic material. A knowledge ofthe concentration of this compound can be
11、an aid in evaluatingthe possible health hazard to persons handling and using thegasoline. This test method is not intended to evaluate suchhazards.5. Apparatus5.1 ChromatographAny chromatographic instrument thathas a backflush system and thermal conductivity detector, andthat can be operated at the
12、conditions given in Table 1, can beemployed. Two backflush systems are shown. Fig. 1 is apressure system and Fig. 2 is a switching valve system. Eitherone can be used.1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products, Liquid Fuels, and Lubricants and is the direc
13、t responsibility ofSubcommittee D02.04.0L on Gas Chromatography Methods.Current edition approved Oct. 1, 2010. Published November 2010. Originallyapproved in 1977. Last previous edition approved in 2007 as D360607. DOI:10.1520/D3606-10E01.2For referenced ASTM standards, visit the ASTM website, www.a
14、stm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO B
15、ox C700, West Conshohocken, PA 19428-2959. United States15.2 Columns:5.2.1 Column AOne 0.8 m (2.5 ft) by 3.2 mm (18 in.)outside diameter stainless steel column packed with 10 mass %dimethylpolysiloxane (for example, OV-101) on ChromosorbW, 60 to 80 mesh.5.2.2 Column BOne 4.6 m (15 ft) by 3.2 mm outs
16、idediameter stainless steel column packed with 20 mass % TCEPon Chromosorb P, 80 to 100 mesh.5.3 Recordera strip chart recorder. An electronic integrat-ing device or a computer capable of graphical presentation ofthe chromatogram. The electronic integrating device or com-puter must be capable of mea
17、suring 0.1 volume % MEK withsatisfactory signal-to-noise. If a strip chart recorder is to beused, a 0 mV to 1 mV range recording potentiometer with aresponse time of 2 s or less and a maximum noise level of60.3 % of full scale is recommended. The detector strip chartrecorder combination must produce
18、a4mmdeflection for a2 L sample containing 0.1 volume % MEK when operated atmaximum sensitivity.5.4 Microsyringe 5 L capacity.5.5 Volumetric Pipets, Class A0.5, 1, 5, 10, 15, and 20 mLcapacities (see Specification E694 and E969).5.6 Measuring Pipets1 mL and 2 mL capacities calibratedin 0.01 mL; 5 mL
19、calibrated in 0.1 mL, for use in dispensingvolumes of benzene and toluene not covered by the volumetricpipets (see Specification E1044 and E1293) during preparationof standard samples (see 11.1).NOTE 1Other volume dispensing equipment capable of delivering thespecified volumes within the stated tole
20、rance limits may be used as analternative to the requirements stated in 5.5 and 5.6.5.7 Flasksvolumetric, 25 mL and 100 mL capacity.5.8 Vibratorelectric.5.9 Vacuum Source.5.10 Evaporatorvacuum, rotary.5.11 Flaskboiling, round-bottom, short-neck, with2440 standard taper joint, 500 mL capacity. Suitab
21、le for usewith evaporator (5.10).5.12 Lampinfrared.5.13 Buretsautomatic, with integral reservoir, 25 mL ca-pacity.6. Materials6.1 Carrier GasHelium, 99.99 % pure. (WarningCompressed gas under high pressure.)6.2 SupportCrushed firebrick, acid-washed, 60 to 80-mesh and 80 to 100-mesh.6.3 Liquid Phases
22、1, 2, 3-Tris(2-cyanoethoxy) propane(TCEP) and methyl silicone.36.4 Solvents:6.4.1 Methanolreagent grade. (WarningFlammable.Vapor harmful. Can be fatal or cause blindness if swallowed orinhaled.)6.4.2 Chloroformreagent grade. (WarningCan be fatalif swallowed. Harmful if inhaled.)6.4.3 Methylene Chlor
23、idefor cleaning columns.(WarningHarmful if inhaled. High concentrations can causeunconsciousness or death.)6.4.4 Acetonefor cleaning columns. (WarningExtremely flammable. Vapors can cause flash fires.)6.5 Internal Standard:6.5.1 Methyl Ethyl Ketone (MEK)99.5% minimum purity.(WarningFlammable. Vapor
24、can be harmful.)6.6 Calibration Standards6.6.1 Benzene99+mol %. (WarningPoison. Carcino-gen. Harmful or fatal if swallowed. Extremely flammable.Vapors can cause flash fires.)6.6.2 Isooctane (2,2,4trimethyl pentane)99+mol %.(Warning Extremely flammable. Harmful if inhaled.)6.6.3 Toluene(WarningFlamma
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD36062010E1STANDARDTESTMETHODFORDETERMINATIONOFBENZENEANDTOLUENEINFINISHEDMOTORANDAVIATIONGASOLINEBYGASCHROMATOGRAPHY

链接地址:http://www.mydoc123.com/p-515086.html