ASTM D3594-1993(2013) Standard Test Method for Copolymerized Ethyl Acrylate In Ethylene-Ethyl Acrylate Copolymers《乙烯丙烯酸酯共聚物中共聚丙烯酸酯含量的标准试验方法》.pdf
《ASTM D3594-1993(2013) Standard Test Method for Copolymerized Ethyl Acrylate In Ethylene-Ethyl Acrylate Copolymers《乙烯丙烯酸酯共聚物中共聚丙烯酸酯含量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3594-1993(2013) Standard Test Method for Copolymerized Ethyl Acrylate In Ethylene-Ethyl Acrylate Copolymers《乙烯丙烯酸酯共聚物中共聚丙烯酸酯含量的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D3594 93 (Reapproved 2013)Standard Test Method forCopolymerized Ethyl Acrylate In Ethylene-Ethyl AcrylateCopolymers1This standard is issued under the fixed designation D3594; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revis
2、ion, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers ethylene-ethyl acrylate copoly-mers containing from 1 to 25 % ethyl acrylate
3、comonomer.1.2 The values stated in SI units are to be regarded asstandard. (See IEEE/ASTM SI-10.)1.3 This standard does not purport to address all of thesafety problems, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health
4、practices and determine the applica-bility of regulatory limitations prior to use.NOTE 1There is no known ISO equivalent to this standard.2. Referenced Documents2.1 ASTM Standards:2D883 Terminology Relating to PlasticsD1898 Practice for Sampling of Plastics (Withdrawn 1998)3E131 Terminology Relating
5、 to Molecular SpectroscopyE168 Practices for General Techniques of Infrared Quanti-tative AnalysisE177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE275 Practice for Describing and Measuring Performance ofUltraviolet and Visible SpectrophotometersIEEE/ASTM SI-10 Standard for U
6、se of the InternationalSystem of Units (SI): The Modern Metric System3. Terminology3.1 See Terminology D883.4. Summary of Test Method4.1 The infrared absorption band at 11.60 m responds toincreases in comonomer content. There is no absorption at thiswavelength when there is no comonomer present. It
7、apparentlyis unique and characteristic of the copolymer. There is nointerference from the monomer at this wavelength.4.2 The infrared absorption band at 11.60 m is of mediumintensity; consequently, fairly thick films are employed. This isan advantage in that errors in measurements of the thicknesses
8、of films have minimal influence on the analytical result. Filmthickness is selected so that not more than 80 % of the infraredenergy is absorbed at the analytical wavelength. The approxi-mate thicknesses found to be satisfactory for different concen-trations of comonomer are as follows: (1) less tha
9、n 5 weight %ethyl acrylate = 0.5 mm, (2) 5 to 15 weight % ethyl acry-late = 0.25 mm, and (3) 15 to 25 weight % ethyl acry-late = 0.18 mm. It is necessary first to press a film approxi-mately 0.25 mm in thickness and scan it to observe theabsorption intensity unless the approximate ethyl acrylatecont
10、ent is known.4.3 For the highest precision, the test method requires thatthe thickness of the sample film be determined accurately.4.4 The general procedure is to scan the absorption bandfrom 10.50 to 12.50 m, although a single-point measurementmay also be used. This test method describes the use of
11、 a scanand employs the base-line method as outlined in 7.2 and thefigure illustrating the Base-Line Method for Measuring Absor-bance of Practices E168. A calibration curve is prepared byplotting absorbance per millimetre values versus weight per-cent ethyl acrylate for several copolymers which have
12、hadethyl acrylate contents established by a fast neutron activationanalysis of oxygen content. The ethyl acrylate content of anunknown sample is then obtained by referring the absorbanceper millimetre value to the calibration curve.5. Significance and Use5.1 Ethyl acrylate is copolymerized with ethy
13、lene to pro-duce film, molding, and wire coating resins with improvedphysical properties. Ethyl acrylate comonomer increasesflexibility, stress cracking resistance, toughness, and clarity. Arapid quantitative technique is needed for the evaluation of the1This test method is under the jurisdiction of
14、ASTM Committee D20 on Plasticsand is the direct responsibility of Subcommittee D20.70 on Analytical Meth-ods.70.08).Current edition approved April 1, 2013. Published April 2013. Originallyapproved in 1977. Last previous edition approved in 2006 as D3594 - 93(2006).DOI: 10.1520/D3594-93R13.2For refer
15、enced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced on
16、www.astm.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1amount of ethyl acrylate in a resin for specification purposesbecause physical properties change rapidly with increasingcomonomer content.5.2 Infrared spectrophotometric ana
17、lysis, when suitablycalibrated, can be used for the measurement of the concentra-tion of comonomer present. Calibration is performed withsamples that have been analyzed for oxygen content by fastneutron activation analysis. Oxygen content is converted toethyl acrylate comonomer content by a simple c
18、alculation.5.3 A purpose of the infrared method of analysis is toprovide a procedure for use in quality control analysis. It is arapid, secondary method of analysis as contrasted with themore expensive and time-consuming fast neutron activationanalysis which is the primary, calibrating method.6. App
19、aratus6.1 Infrared Spectrophotometer,4capable of spectral resolu-tion4equivalent to that defined by Practice E275 and exhibitedin Fig. 7 of that practice. The instrument should be capable ofscale expansion along the wavelength (or wave number) axis.6.1.1 Fourier Transform Infrared Spectrophotometer
20、(FT-IR), with nominal 4 cm1resolution.6.2 Compression-Molding Press, small, with platens ca-pable of being heated to 150C.6.3 Metal Plates, two, 150 by 150 mm or larger, of 0.5-mmthickness with smooth surfaces, chromium plated preferably.6.4 Brass Shims, three, approximately 75 by 75 mm andthickness
21、es of 0.50 mm, 0.25 mm, and 0.18 mm, with anaperture in the center at least 25 by 38 mm.6.5 Micrometer Calipers, with thimble graduations of 0.001mm.6.6 Film Mounts, with apertures at least 6 by 27 mm to holdthe specimens in the spectrophotometer.7. Material7.1 Polyethylene Terephthalate or Aluminum
22、 Sheets, 80 by80-mm, or slightly larger, to cover brass shims.8. Hazards8.1 Use gloves when plaques are prepared using a heatedpress. Take care to avoid burns when handling microscopicslides with the hot plate.8.2 The optical bench of the FT-IR spectrophotometercontains a laser. To avoid eye injury,
23、 do not stare directly intothe laser beam.9. Sampling9.1 The copolymer shall be sampled in accordance withPractice D1898.10. Calibration10.1 It is necessary to establish the ethyl acrylate comono-mer content of at least eight calibration samples by anindependent method. The samples should vary in et
24、hyl acrylatecontent over the range from near zero to about 25 %.Amethodthat has been found to give high precision and accuracy foroxygen content is fast neutron activation analysis.5The ethylacrylate comonomer content, E, is calculated from the oxygenanalysis, assuming that all oxygen present is due
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD359419932013STANDARDTESTMETHODFORCOPOLYMERIZEDETHYLACRYLATEINETHYLENEETHYLACRYLATECOPOLYMERS 乙烯

链接地址:http://www.mydoc123.com/p-515063.html