ASTM D3493-2013 Standard Test Method for Carbon BlackOil Absorption Number of Compressed Sample (COAN)《碳黑的标准试验方法 压制样品的吸油值(COAN)》.pdf
《ASTM D3493-2013 Standard Test Method for Carbon BlackOil Absorption Number of Compressed Sample (COAN)《碳黑的标准试验方法 压制样品的吸油值(COAN)》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3493-2013 Standard Test Method for Carbon BlackOil Absorption Number of Compressed Sample (COAN)《碳黑的标准试验方法 压制样品的吸油值(COAN)》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D3493 13Standard Test Method forCarbon BlackOil Absorption Number of CompressedSample (COAN)1This standard is issued under the fixed designation D3493; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last r
2、evision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the procedure for the mechani-cal compression of a carbon black sample and the determina-tion of the
3、 oil absorption number of the compressed sample.1.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibili
4、ty of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1765 Classification System for Carbon Blacks Used inRubber ProductsD1799 Practice for Carbon Black
5、Sampling PackagedShipmentsD1900 Practice for Carbon BlackSampling Bulk Ship-mentsD2414 Test Method for Carbon BlackOil AbsorptionNumber (OAN)D4821 Guide for Carbon BlackValidation of Test MethodPrecision and BiasD4483 Practice for Evaluating Precision for Test MethodStandards in the Rubber and Carbo
6、n Black ManufacturingIndustries3. Summary of Test Method3.1 A sample of carbon black is compressed four times in acompression cylinder at a pressure of 165 MPa (24 000 psi)and then tested in an absorptometer to determine the oilabsorption number.3.2 n-Dibutyl phthalate, paraffin, or EFA oil is added
7、 bymeans of a constant-rate buret to the compressed sample ofcarbon black in the mixer chamber of an absorptometer.As thesample absorbs the oil, the mixture changes from a free-flowing state to one of a semiplastic agglomeration, with anaccompanying increase in viscosity. This increased viscosity is
8、transmitted to the torque-sensing system of the absorptometer.When the viscosity of the mixture reaches a predeterminedtorque level, the absorptometer and buret will simultaneouslyshut off. The volume of oil added is read from the directreading buret. The volume of oil per unit mass of carbon blacki
9、s the oil absorption number. Either DBP, paraffin, or EFA oilis acceptable for use with many standard pelleted grades ofN-series carbon blacks found in Classification D1765. COANtesting using paraffin or EFA oil on some specialty blacks andpowder blacks may result in significant differences whencomp
10、ared to COAN testing using DBP oil. Referee testingbetween suppliers and users should use DBPoil until such timethat precision data is available for paraffin and EFA oils.4. Significance and Use4.1 The oil absorption number of a carbon black is related tothe processing and vulcanizate properties of
11、rubber compoundscontaining the carbon black.4.2 The difference between the regular oil absorption num-ber and the oil absorption number of compressed sample issome measure of the stability of the structure of the carbonblack.5. Apparatus35.1 Balance, analytical, 0.01-g sensitivity.1This test method
12、is under the jurisdiction of ASTM Committee D24 on CarbonBlack and is the direct responsibility of Subcommittee D24.11 on Carbon BlackStructure.Current edition approved July 1, 2013. Published August 2013. Originallyapproved in 1976. Last previous edition approved in 2009 as D3493 09. DOI:10.1520/D3
13、493-13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Each apparatus is to be operated and maintained in ac
14、cordance with themanufacturers directions for optimum performance.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15.2 Oven, gravity-convection type, capable of maintaining125C 6 5C.5.3 Carbon Black Press, capable of compressing a 25-g
15、sample to 165 MPa (24 000 psi).45.4 Absorptometer,5equipped with a constant-rate buret thatdelivers 67 6 0.4 mm3/s (4 6 0.024 cm3/min).5.5 Spatula, rubber, 100 mm.5.6 Sieve, 850 m (U.S. No. 20), approximately 125-mm(5-in.) diameter with receiver pan.5.7 Brush, approximately 40 mm (1.5 in.), stiff br
16、istle.5.8 Desiccator.6. Reagent and Standards6.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,where such s
17、pecifications are available.6Other grades may beused, provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.6.2 n-Dibutyl Phthalate, having a density of 1.042 to1.047 mg/m3at 25C and a relative density of
18、1.045 to 1.050at 25C.6.3 Paraffn Oil, having a kinematic viscosity of 10 to34 mm2/s (cSt) at 40C.76.4 Epoxidized Fatty Acid Ester (EFA), meeting the speci-fications listed in Test Method D2414, Table 1. It is recom-mended to store the product at temperatures between 7 and30C. If stored in sealed ori
19、ginal containers, the product isstable for at least 12 months. For handling and safety, pleaserefer to safety data sheet.6.5 ASTM D24 Standard Reference Blacks, SRB.87. Sampling7.1 Samples shall be taken in accordance with PracticesD1799 and D1900.8. Calibration and Standardization8.1 See Test Metho
20、d D2414.NOTE 1If values are not obtained within the acceptable range, it willbe necessary to either vary the pressure of the hydraulic press untilacceptable values are obtained or follow Guide D4821.9. Procedure9.1 Dry an adequate sample for1hinaspecified oven setat 125C. Cool the sample in a desicc
21、ator for a minimum of30 min prior to testing.9.2 Weigh a sample mass of either 25, 30, or 45 g dependingon the sample mass requirement for oil absorption per TestMethod D2414. The desired sample mass to be compressedwill weigh 5 6 0.1 g greater than the mass specified insubsection 9.2 of Test Method
22、 D2414.9.3 Compress the sample using either the Chandler or Titanpress.9.4 Chandler Press:9.4.1 Place the bottom seal plate and the compressioncylinder in the hydraulic press. Move the handle of the sealplate to check its position in the support plate. Rotate thecylinder to be certain that it fits o
23、n the seal plate.9.4.2 Place the carbon black sample in the compressioncylinder and insert the piston with the nylon spacer next to thecarbon black. Rotate the piston while pressing it into thecylinder as far as possible by hand.9.4.3 Adjust the alignment of the piston, cylinder, and ramto prevent g
24、alling of the cylinder.9.4.4 Compress the carbon black to approximately 165 MPa(24 000 psi), hold for about 1 s, then release. The exactpressure is determined by measuring the compressed oil. Avalue of the SRB materials and making appropriate adjust-ments. If the values are too high, the pressure is
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD34932013STANDARDTESTMETHODFORCARBONBLACKOILABSORPTIONNUMBEROFCOMPRESSEDSAMPLECOAN 碳黑 标准 试验 方法 压制

链接地址:http://www.mydoc123.com/p-514879.html