ASTM D3195 D3195M-2010(2015) Standard Practice for Rotameter Calibration《转子流量计校准的标准实施规程》.pdf
《ASTM D3195 D3195M-2010(2015) Standard Practice for Rotameter Calibration《转子流量计校准的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3195 D3195M-2010(2015) Standard Practice for Rotameter Calibration《转子流量计校准的标准实施规程》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D3195/D3195M 10 (Reapproved 2015)Standard Practice forRotameter Calibration1This standard is issued under the fixed designation D3195/D3195M; the number immediately following the designation indicates theyear of original adoption or, in the case of revision, the year of last revision. A
2、 number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the calibration of variable-areaflowmeters (rotameters) used to determine air sample volumesat or close to ambien
3、t conditions of pressure and temperature,in the analysis of atmospheres for pollutant content.1.2 UnitsThe values stated in either SI units or inch-pound units are to be regarded separately as standard. Thevalues stated in each system may not be exact equivalents;therefore, each system shall be used
4、 independently of the other.Combining values from the two systems may result in non-conformance with the standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate s
5、afety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1071 Test Methods for Volumetric Measurement of Gas-eous Fuel SamplesD1356 Terminology Relating to Sampling and Analysis ofAtmospheresD3631 Test Methods for
6、Measuring Surface AtmosphericPressureE1 Specification for ASTM Liquid-in-Glass ThermometersE337 Test Method for Measuring Humidity with a Psy-chrometer (the Measurement of Wet- and Dry-Bulb Tem-peratures)E1137/E1137M Specification for Industrial Platinum Resis-tance ThermometersE2251 Specification f
7、or Liquid-in-Glass ASTM Thermom-eters with Low-Hazard Precision Liquids3. Terminology3.1 Definitions:3.1.1 For definitions of terms used in this practice, refer toTerminology D1356.3.1.2 Standard conditions are taken as 25C 77F and101.3 kPa (760 mm Hg) at existing ambient humidity. Thisconforms to m
8、ost of the ASTM methods for atmosphericsampling and analysis that involve volumetric corrections.Absolute temperature scales are to be used when substitutingvalues into the formulae used in this procedure.4. Summary of Practice4.1 Two alternative methods of performing the requiredvolume determinatio
9、ns for rotameter calibration are described:4.1.1 Using the water-sealed rotating drum meter (wet testmeter). See Section 7.4.1.2 Using the volumetric gasometer (bell prover). SeeSection 8.5. Significance and Use5.1 Choice of method depends primarily on which equip-ment is available. Higher accuracy
10、is possible with the gasom-eter. The accuracies of the methods of atmospheric analysis, forwhich the calibration procedure is intended, do not warrant thevery highest possible accuracy in flow measurement.6. Apparatus6.1 Wet Test Meter, or Volumetric Gasometer, with waterseal and equipped with a wat
11、er manometer on the inlet.6.2 Counter Balance Weights, for gasometer.6.3 Mercury BarometerSee Test Methods D3631.6.4 Psychrometer, (if room air is used for calibration gas).See Test Method E337.6.5 Thermometer, to measure ambient temperature. SeeSpecifications E1, E1137/E1137M, and E2251.6.6 Stopwat
12、ch.6.7 Air Supply, either a cylinder of compressed air or adiaphragm type pump of adequate capacity and a ballastvolume or restrictor to eliminate pulsations.6.8 Needle Valve.1This practice is under the jurisdiction of ASTM Committee D22 on Air Qualityand is the direct responsibility of Subcommittee
13、 D22.01 on Quality Control.Current edition approved April 1, 2015. Published April 2015. Originallyapproved in 1973. Last previous edition approved in 2010 as D3195/D3195M 10.DOI: 10.1520/D3195_D3195M-10R15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer
14、 Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States17. Procedure Using Wet Test Meter7.1 Unl
15、ess it was already calibrated within the previousthree months, calibrate the wet test meter by Test MethodsD1071. The method described in Section 19 is recommendedfor highest accuracy.7.2 Set up the apparatus as shown in Fig. 1, makingconnections as short as possible and large enough insidediameter
16、to avoid any appreciable pressure drops.7.3 Before and after the complete calibration run, recordroom temperature, barometric pressure in accordance with TestMethods D3631, and relative humidity (when room air is usedfor calibrating gas) in accordance with Test Method E337. Useaverage values for sub
17、sequent calculations.7.4 Start air flowing through the rotameter and wet testmeter.Adjust the flow to the desired rate with the needle valve.Take a pair of timed readings on the wet test meter, understeady flow, for each of five or more uniformly spaced pointson the rotameter scale, going from low v
18、alues to high values.Repeat, going from high to low. Note the manometer readingand meter water temperature for each meter reading.8. Procedure Using Gasometer8.1 Unless it was already calibrated within the previous sixmonths, in the same location, calibrate the gasometer by TestMethods D1071.8.2 Set
19、 up the apparatus as shown in Fig. 2, makingconnections as short as possible and large enough insidediameter to avoid any appreciable pressure drops.8.3 Before and after the complete calibration run, record theroom temperature, barometric pressure, and relative humidity(when room air is used for cal
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD3195D3195M20102015STANDARDPRACTICEFORROTAMETERCALIBRATION 转子 流量计 校准 标准 实施 规程 PDF

链接地址:http://www.mydoc123.com/p-514288.html