ASTM D3175-2007 Standard Test Method for Volatile Matter in the Analysis Sample of Coal and Coke《煤和焦炭分析样品中挥发性物质的标准试验方法》.pdf
《ASTM D3175-2007 Standard Test Method for Volatile Matter in the Analysis Sample of Coal and Coke《煤和焦炭分析样品中挥发性物质的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3175-2007 Standard Test Method for Volatile Matter in the Analysis Sample of Coal and Coke《煤和焦炭分析样品中挥发性物质的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3175 07Standard Test Method forVolatile Matter in the Analysis Sample of Coal and Coke1This standard is issued under the fixed designation D 3175; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revi
2、sion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test method determines the percentage of
3、 gaseousproducts, exclusive of moisture vapor, in the analysis samplewhich are released under the specific conditions of the test.1.2 This test method for determination of volatile matter isempirical; because of its empirical nature, strict adherence tobasic principals and permissible procedures is
4、required toobtain valid results.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitati
5、ons prior to use.1.4 The values stated in SI units are to be regarded as thestandard.2. Referenced Documents2.1 ASTM Standards:2D 346 Practice for Collection and Preparation of CokeSamples for Laboratory AnalysisD 2013 Practice for Preparing Coal Samples for AnalysisD 3173 Test Method for Moisture i
6、n theAnalysis Sample ofCoal and Coke3. Terminology3.1 Definition:3.1.1 sparking fuelswithin the context of this test method,fuels that do not yield a coherent cake as residue in the volatilematter determination but do evolve gaseous products at a ratesufficient to mechanically carry solid particles
7、out of thecrucible when heated at the standard rate. Such coals normallyinclude all low-rank noncaking coals and lignites but can alsoinclude those anthracites, semianthracites, bituminous, andcokes that lose solid particles as described above. These aredefined as sparking fuels because particles es
8、caping at thehigher temperatures can become incandescent and spark asthey are emitted.4. Summary of Test Method4.1 Volatile matter is determined by establishing the loss inweight resulting from heating a coal or coke under rigidlycontrolled conditions. The measured weight loss, corrected formoisture
9、 as determined in Test Method D 3173 establishes thevolatile matter content. Two procedures are described to permitconformity with differences in sample behavior.4.2 In this empirical test method, the use of platinumcrucibles shall be considered the standard reference method forvolatile matter. Plat
10、inum crucibles shall be used in determiningthe volatile matter of coke and volatile matter determined forclassification of coals by rank. Volatile matter determinationsby some laboratories using alternate nickel-chromium alloycrucibles having the physical dimensions specified in 6.1 havebeen shown t
11、o differ from those obtained using platinumcrucibles. A laboratory utilizing nickel-chromium cruciblesshall first determine if a relative bias exists between the use ofnickel-chromium and platinum crucibles on the coals beingtested using the test method set forth in Annex A. Where arelative bias is
12、shown to exist, the volatile matter determinedusing nickel-chromium crucibles shall be corrected by a factordetermined through comparison of volatile matter results fromboth crucible types on coals being tested or analysis of samplesof known proximate analysis.5. Significance and Use5.1 Volatile mat
13、ter, when determined as herein described,can be used to establish the rank of coals, to indicate coke yieldon carbonization process, to provide the basis for purchasingand selling, or to establish burning characteristics.6. Apparatus6.1 Platinum Crucible, with closely fitting cover, for coal.The cru
14、cible shall be of not less than 10 or more than 20-mLcapacity, not less than 25 or more than 35 mm in diameter, andnot less than 30 or more than 35 mm in height.1This test method is under the jurisdiction of ASTM Committee D05 on Coaland Coke and is the direct responsibility of Subcommittee D05.21 o
15、n Methods ofAnalysis.Current edition approved March 1, 2007. Published April 2007. Originallyapproved in 1973. Last previous edition approved in 2002 as D 3175 02.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book
16、 of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.2 Platinum Crucible, with closely fitting cover, for coke.The crucible shall be o
17、f 10-mL capacity, with capsule coverhaving thin flexible sides fitting down into crucible. Or thedouble-crucible method can be used, in which the sample isplaced in 10-mL platinum crucible, which is then covered withanother crucible of such a size that it will fit closely to the sidesof the outer cr
18、ucible and its bottom will rest 8.5 to 12.7 mm (13to12 in.) above the bottom of the outer crucible.6.3 Alternate Crucible Materials, Nickel-chromium cru-cible with closely fitting cover. The crucible shall not be lessthan 10 or more than 20 mL capacity, not less than 25 or morethan 35 mm in diameter
19、, and not less than 30 or more than 35mm in height. Nickel-chromium crucibles shall be heat-treatedfor4hat500C to ensure that they are completely oxidizedprior to use.6.4 Vertical Electric Tube Furnace, for coal or coke. Theelectric furnace shall be a vertical tube furnace. The furnacecan be of the
20、form shown in Fig. 1. It shall be regulated tomaintain a temperature of 950 6 20C in the crucible, asmeasured by a thermocouple positioned in the furnace. Thefurnace shall accommodate sparking coals and meet thespecifications set forth in 7.3.2.FIG. 1 Electric Furnace for Determining Volatile Matter
21、D31750726.5 Balance, sensitive to 0.1 mg.7. Procedure7.1 The sample shall be the material pulverized to No. 60(250-m) sieve in accordance with Practice D 2013 or PracticeD 346.7.2 Procedure for Nonsparking Coals and Cokes:7.2.1 Weigh1gofthesample in a weighed platinumcrucible, close with a cover whi
22、ch fits closely enough so thatthe carbon deposit from bituminous, subbituminous, and lig-nite coals does not burn away from the underside, place onplatinum or Nichrome-wire supports and insert directly into thefurnace chamber, which shall be maintained at a temperature of950 6 20C, and lower immedia
23、tely to the 950C zone.Regulation of the temperature to within the prescribed limits iscritical. After the more rapid discharge of volatile matter hassubsided, as shown by the disappearance of the luminousflame, or in the case of coke, after 2 or 3 min, inspect thecrucible (see Note 1) to verify that
24、 the lid is still properlysealed. If necessary, reseat the lid to guard against the admis-sion of air into the crucible. Do this as rapidly as possible byraising the crucible to the top of the furnace chamber, reposi-tion the lid to more perfectly seal the crucible, then lower thecrucible immediatel
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD31752007STANDARDTESTMETHODFORVOLATILEMATTERINTHEANALYSISSAMPLEOFCOALANDCOKE 焦炭 分析 样品 挥发性 物质 标准 试验

链接地址:http://www.mydoc123.com/p-514227.html