ASTM D3143 D3143M-2013 Standard Test Method for Flash Point of Cutback Asphalt with Tag Open-Cup Apparatus《带标签开杯装置的稀释沥青闪点标准试验方法》.pdf
《ASTM D3143 D3143M-2013 Standard Test Method for Flash Point of Cutback Asphalt with Tag Open-Cup Apparatus《带标签开杯装置的稀释沥青闪点标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3143 D3143M-2013 Standard Test Method for Flash Point of Cutback Asphalt with Tag Open-Cup Apparatus《带标签开杯装置的稀释沥青闪点标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D3143/D3143M 13Standard Test Method forFlash Point of Cutback Asphalt with Tag Open-CupApparatus1This standard is issued under the fixed designation D3143/D3143M; the number immediately following the designation indicates theyear of original adoption or, in the case of revision, the yea
2、r of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of flash pointsby the Tag Open-Cup Apparatus of cutback asphalts having
3、flash points of less than 93C 200F.NOTE 1Specifications commonly designate the Cleveland Open Cup(Test Method D92IP 36) Method for asphalt cements and cutbackasphalts having flash points above 79C 175F.NOTE 2This procedure follows in general the procedure outlined inTest Method D1310, but is restric
4、ted to cutback asphalt having flash pointsof less than 93C 200F.1.2 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combini
5、ngvalues from the two systems may result in non-conformancewith the standard.1.3 WarningMercury has been designated by the UnitedStates Environmental Protection Agency and many state agen-cies as a hazardous material that can cause central nervoussystem, kidney and liver damage. Mercury, or its vapo
6、r, may behazardous to health and corrosive to materials. Caution shouldbe taken when handling mercury and mercury containingproducts. See the applicable Material Safety Data Sheet(MSDS) for details and EPAs website (http:/www.epa.gov/mercury/index.htm) for additional information. Users shouldbe awar
7、e that selling mercury and/or mercury containingproducts into your state may be prohibited by state law.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and
8、health practices and determine the applica-bility of regulatory limitations prior to use.1.5 This standard should be used to measure and describethe properties of materials, products, or assemblies in responseto heat and flame under controlled laboratory conditions andshould not be used to describe
9、or appraise the fire hazard orfire risk of materials, products, or assemblies under actual fireconditions. However, results of this test may be used aselements of a fire risk assessment which takes into account allof the factors which are pertinent to an assessment of the firehazard of a particular
10、end use.2. Referenced Documents2.1 ASTM Standards:2D92 Test Method for Flash and Fire Points by ClevelandOpen Cup TesterD140 Practice for Sampling Bituminous MaterialsD1310 Test Method for Flash Point and Fire Point of Liquidsby Tag Open-Cup ApparatusD4057 Practice for Manual Sampling of Petroleum a
11、ndPetroleum ProductsD4177 Practice for Automatic Sampling of Petroleum andPetroleum ProductsD6299 Practice for Applying Statistical Quality Assuranceand Control Charting Techniques to Evaluate AnalyticalMeasurement System PerformanceD6300 Practice for Determination of Precision and BiasData for Use
12、in Test Methods for Petroleum Products andLubricantsE1 Specification for ASTM Liquid-in-Glass ThermometersE77 Test Method for Inspection and Verification of Ther-mometersE300 Practice for Sampling Industrial ChemicalsE644 Test Methods for Testing Industrial Resistance Ther-mometersE1137/E1137M Speci
13、fication for Industrial Platinum Resis-tance Thermometers2.2 IP Standard:IP 36 Test for Flash and Fire Points by Cleveland Open Cup31This test method is under the jurisdiction of ASTM Committee D04 on Roadand Paving Materials and is the direct responsibility of Subcommittee D04.47 onMiscellaneous As
14、phalt Tests.Current edition approved Dec. 1, 2013. Published January 2014. Originallyapproved in 1962. Last previous edition approved in 2008 as D3143 08. DOI:10.1520/D3143_D3143M-13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.
15、org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Energy Institute, 61 New Cavendish St., London, WIG 7AR,U.K., http:/www.energyinst.org.uk.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West C
16、onshohocken, PA 19428-2959. United States13. Summary of Test Method3.1 The sample is placed in the cup of the tester and heatedat a slow but constant rate. A small test flame is passed at auniform rate in a level plane across the cup at specifiedintervals. The flash point is the lowest temperature a
17、t whichapplication of the test flame causes the vapor at the surface ofthe liquid to flash.4. Significance and Use4.1 This test method is useful in determining that an asphaltcutback has been prepared with solvents that meet the desiredrange of flammability, and that the product has not beencontamin
18、ated with lower flash point solvents.5. Apparatus5.1 Flash TesterTag Open-Cup Tester (manual) (Fig.A1.1) as described in detail in Annex A1.5.2 Shield, as described in detail in Annex A1.5.3 ThermometerA thermometer for measuring the tem-perature of the sample. The thermometer shall be one of thefol
19、lowing:5.3.1 An ASTM 9C 9F liquid-in-glass thermometer withsubdivisions and maximum scale error of 0.5C 1F whichconforms to the requirements of Specification E1. The ther-mometer shall be standardized in accordance with one of themethods in Test Method E77.5.3.2 Aplatinum resistance thermometer (PRT
20、) with a probewhich conforms to the requirements of Specification E1137/E1137M. The PRT shall have a 3- or 4-wire configuration andthe overall sheath length shall be at least 50 mm 2 in. greaterthan the immersion depth. Calibrate the PRT system (probe andreadout) in accordance with Test Methods E644
21、.6. Reagents and Materials6.1 Bath Media:6.1.1 Water, for flash points to 79C 175F.6.1.2 Water-Glycol Solution (1 + 1), for flash points above79C 175F.6.2 Cleaning SolventsUse technical grade solvent capableof cleaning out the test specimen from the test cup and dryingthe test cup.7. Sampling7.1 Obt
22、ain a sample in accordance with the instructionsgiven in Practices D140, D4057, D4177,orE300.7.2 Transfer sample to the test cup when the sample is atleast 10C 18F below the expected flash point. Erroneouslyhigh flash points may be obtained if precautions are not takento avoid loss of volatile mater
23、ial. Do not open containersunnecessarily; this will prevent the loss of volatile material andpossible introduction of moisture. When possible, the flashpoint should be the first test performed on a sample.8. Assembly and Preparation of Apparatus8.1 Place the tester in a level position on a solid vib
24、ration-free table in a location free of draft. Shield the top of the testerfrom strong light so that the flash may be easily seen. Maintaina room temperature of 25 6 5C 77 6 10F throughout thetest.8.2 Adjust the horizontal and vertical positions of theignition taper so that the jet passes on the cir
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD3143D3143M2013STANDARDTESTMETHODFORFLASHPOINTOFCUTBACKASPHALTWITHTAGOPENCUPAPPARATUS 标签 装置 稀释 沥青

链接地址:http://www.mydoc123.com/p-514146.html