ASTM D3134-2015 Standard Practice for Establishing Color and Gloss Tolerances《建立颜色和光泽度偏差的标准实践规程》.pdf
《ASTM D3134-2015 Standard Practice for Establishing Color and Gloss Tolerances《建立颜色和光泽度偏差的标准实践规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3134-2015 Standard Practice for Establishing Color and Gloss Tolerances《建立颜色和光泽度偏差的标准实践规程》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D3134 97 (Reapproved 2008)1D3134 15Standard Practice forEstablishing Color and Gloss Tolerances1This standard is issued under the fixed designation D3134; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of las
2、t revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1 NOTECorrections were made editorially in Footnote 4, 7.2.1, and Section 12 in December 2008.INTRODUCTIONPermissible color and gloss
3、 deviations from a standard are generally dependent upon the colordiscrimination of the observer, on the lighting and surround in which the material is viewed, and onspecial considerations related to the design, manufacture, and practical usage of the colored materialor object. The tolerances, there
4、fore, may be influenced by economic, technical, psychological, andpractical requirements. In many circumstances, acceptability of color and gloss deviations from astandard may differ appreciably from the perceptibility of deviations such as on-tone fadingpreferences, large tolerances for luminance v
5、ariation, nongreen bias, or nonyellow bias. perceptibilityfor many reasons. With proper allowances, perceptibility data can be used as an aid to developpermissible tolerances. Finally, the sum of all these considerations should result in a specificationacceptable to both buyer and seller.1. Scope1.1
6、 This practice describes a procedure for establishing tolerances and evaluating the color and gloss of specimens with respectto specified standards. This practice is appropriate for nonfluorescent opaque specimens.1.2 This practice does not indicate the extent of tolerances, but gives guidance on ho
7、w they can be set. For product specification,the tolerances between specimens and the specified standard should be agreed upon between the purchaser and the seller.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof th
8、e user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D523 Test Method for Specular GlossD1535 Practice for Specifying Color by the Munsell SystemD1729 Practice for
9、 Visual Appraisal of Colors and Color Differences of Diffusely-Illuminated Opaque MaterialsD2244 Practice for Calculation of Color Tolerances and Color Differences from Instrumentally Measured Color CoordinatesD3964 Practice for Selection of Coating Specimens for Appearance MeasurementsD4449 Test Me
10、thod for Visual Evaluation of Gloss Differences Between Surfaces of Similar AppearanceD5531 Guide for Preparation, Maintenance, and Distribution of Physical Product Standards for Color and GeometricAppearance of CoatingsE284 Terminology of AppearanceE308 Practice for Computing the Colors of Objects
11、by Using the CIE SystemE312 Practice for Description and Selection of Conditions for Photographing Specimens Using Analog (Film) Cameras andDigital Still Cameras (DSC)E805 Practice for Identification of Instrumental Methods of Color or Color-Difference Measurement of Materials1 This practice is unde
12、r the jurisdiction of ASTM Committee E12 on Color and Appearance and is the direct responsibility of Subcommittee E12.11 on Visual Methods.Current edition approved Dec. 1, 2008Jan. 1, 2015. Published December 2008February 2015. Originally approved in 1972. Last previous edition approved in 20032008a
13、s D3134 97 (2003).(2008)1. DOI: 10.1520/D3134-97R08E01.10.1520/D3134-15.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the AS
14、TM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consul
15、t prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1E1164 Practice for Obtaining Spectrom
16、etric Data for Object-Color EvaluationE1331 Test Method for Reflectance Factor and Color by Spectrophotometry Using Hemispherical GeometryE1345 Practice for Reducing the Effect of Variability of Color Measurement by Use of Multiple MeasurementsE1349 Test Method for Reflectance Factor and Color by Sp
17、ectrophotometry Using Bidirectional (45:0 or 0:45) GeometryE1360 Practice for Specifying Color by Using the Optical Society of America Uniform Color Scales SystemE1499 Guide for Selection, Evaluation, and Training of ObserversE1541 Practice for Specifying and Matching Color Using the Colorcurve Syst
18、em (Withdrawn 2007)3E1708 Practice for Electronic Interchange of Color and Appearance Data2.2 CIE Publication:No. CIE S 014-4/E2007Publication 015 Colorimetry 2nd ed.42.3 ISO Standard:ISO 15930 Graphic Technology Part 4: Complete exchange of CMYK and spot colour printing data using PDF 1.4 (PDF/X-la
19、)3. Terminology3.1 DefinitionsFor definitions of terms related to this practice see Terminology E284.4. Summary of Practice4.1 This practice consists of recommendations for the selection of a standard, the necessary physical measurements to assessthe permanence of the standard to reproduce it when n
20、eeded, and to establish tolerances.4.2 Recommendations are given for the determination of the conformance of a specimen to preestablished color and glosstolerances by instrumental or visual means.5. Significance and Use5.1 Color specifications are centered around exact positions in color space. Corr
21、espondingly, gloss specifications are centeredaround an exact position on the gloss scale. Because it is difficult to achieve these exact positions repeatedly, it is necessary tospecify tolerances that are acceptable to both the buyer and the seller. This practice details the procedure for accomplis
22、hing thisgoal.6. Specimens6.1 The exact method of preparation of the specimen shall be agreed upon between the purchaser and the seller. However, forthe highest precision in instrumental measurements the specimens should be opaque, uniform in color, plane, and uniform intexture. The specimens should
23、 be relatively permanent, and capable of being cleaned. Preferred sizes of specimens for visualevaluation are given in Practice D1729, the specific size being governed by the use of the specimens.7. Procedure7.1 Selection and Specification of Color and Gloss Standard:7.1.1 Select a standard in accor
24、dance with Practice D3964 that is preferably the same type of material as the specimens to beevaluated for color or gloss, or both. Prepare, in sufficient quantity, secondary standards in accordance with Guide D5531 that arerepresentative of the desired color and gloss, in the permanent material. St
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD31342015STANDARDPRACTICEFORESTABLISHINGCOLORANDGLOSSTOLERANCES 建立 颜色 光泽 偏差 标准 实践 规程 PDF

链接地址:http://www.mydoc123.com/p-514122.html