ASTM D3070-2000(2010) Standard Test Method of Rapid Pressure Determination of Pressurized Products《加压制品的快速压力测定的标准试验方法》.pdf
《ASTM D3070-2000(2010) Standard Test Method of Rapid Pressure Determination of Pressurized Products《加压制品的快速压力测定的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3070-2000(2010) Standard Test Method of Rapid Pressure Determination of Pressurized Products《加压制品的快速压力测定的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D3070 00 (Reapproved 2010)Standard Test Method ofRapid Pressure Determination of Pressurized Products1This standard is issued under the fixed designation D3070; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year
2、of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test method covers rapid pres
3、sure determination forpressurized products.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.3 This standard does not purport to addr
4、ess all of thesafety concerns, if any, associated with its use. It is theresponsibility of whoever uses this standard to consult andestablish appropriate safety and health practices and deter-mine the applicability of regulatory limitations prior to use.2. Significance and Use2.1 This test method is
5、 a rapid technique for quality control,formula development, etc., where speed is necessary and a highdegree of accuracy is not essential.3. Apparatus3.1 Pressure Gage, stainless steel construction, with a rangefrom 0 to 160 psi (0 to 1.1 MPa), and preferably with onenumber graduations. The gage shou
6、ld be attached to a18-in.Hoke needle valve, with all of the connections leak proof.Attach an adaptor to the needle valve to fit the aerosol valveson the cans to be tested (Fig. 1).NOTE 1Take care that there are no leaks in the gage apparatus. Thiscan be checked by occasionally making a measurement w
7、ith the attach-ment under water.3.1.1 Care should be taken to clean the gage daily byrepeated injection and venting of an approved cleaning solutioncontaining a bacteriastat. After cleaning, rinse the gage andapparatus with clean water and purge them with the prepres-surizing gas prior to use.3.1.2
8、For nonfood products, the gage apparatus may becleaned between product uses by forcing suitable solvents intothe gage, then venting it. This should be repeated several timesuntil the gage is free of contamination.NOTE 2When changing from chlorinated solvents to water-baseproducts, and vice versa, th
9、e above is particularly important to avoidpossible contamination.3.1.3 Use a separate gage apparatus for food products only.3.2 Water Bath, constant-temperature, accurate to at least61F (60.5C).1This test method is under the jurisdiction of ASTM Committee D10 onPackaging and is the direct responsibi
10、lity of Subcommittee D10.33 on MechanicalDispensers. Originally developed by the Chemical Specialties Manufacturers Assn.Current edition approved Oct. 1, 2010. Published November 2010. Originallyapproved in 1972. Last previous edition approved in 2005 as D3070 00 (2005).DOI: 10.1520/D3070-00R10.FIG.
11、 1 Pressure Gage Apparatus1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4. Reagents4.1 Pressurizing Gas:4.1.1 For nonfood products the following are recom-mended:4.1.1.1 Carbon Dioxide (CO2).4.1.1.2 Compressed Air.4.1.1.3 Nitrogen
12、(N2).4.1.2 For food products the following are recommended:4.1.2.1 Carbon Dioxide (CO2).4.1.2.2 Nitrogen (N2).4.1.2.3 Nitrous Oxide (N2O).NOTE 3Suitable pressurizing gases for food products should belimited to those that are not liquefiable at the temperatures and pressuresused. Compressed air is no
13、t recommended because of its oxygen content.5. Sampling5.1 Normal production or laboratory samples shall be usedfor this test.6. Calibration6.1 A suitable standard check, accurate to 60.5 psi (3.4kPa), should be set up in the laboratory for quick calibration ofthe test gage.6.2 Gages in constant use
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD307020002010STANDARDTESTMETHODOFRAPIDPRESSUREDETERMINATIONOFPRESSURIZEDPRODUCTS 加压 制品 快速 压力 测定 标准

链接地址:http://www.mydoc123.com/p-514044.html