1、Designation: D 2972 03Standard Test Methods forArsenic in Water1This standard is issued under the fixed designation D 2972; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicate
2、s the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 These test methods2cover the photometric and atomicabsorption determination of arsenic in most waters and waste-waters. Three test methods are given as follows:Con
3、centrationRangeSectionsTest Method ASilver Diethyldithio-carbamate Colorimetric5 to 250 g/L 7 to 15Test Method BAtomic Absorption,Hydride Generation1to20g/L 16to24Test Method CAtomic Absorption,Graphite Furnace5to100g/L 25to331.2 The analyst should direct attention to the precision andbias statement
4、s for each test method. It is the users responsi-bility to ensure the validity of these test methods for waters ofuntested matrices.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establ
5、ish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardstatements, see Note 1 and Note 6.2. Referenced Documents2.1 ASTM Standards:D 1129 Terminology Relating to Water3D 1193 Specification for Reagent Water3D 2777 Prac
6、tice for Determination of Precision and Bias ofApplicable Methods of Committee D19 on Water3D 3370 Practices for Sampling Water from Closed Con-duits3D 3919 Practice for Measuring Trace Elements in Water byGraphite Furnace Atomic Absorption Spectrophotometry3D 4841 Practice for Estimation of Holding
7、 Time for WaterSamples Containing Organic and Inorganic Constituents3D 5810 Guide for Spiking into Aqueous Samples3D 5847 Practice for the Writing Quality Control Specifica-tions for Standard Test Methods for Water Analysis3E60 Practice for Photometric and SpectrophotometricMethods for Chemical Anal
8、ysis of Metals4E 275 Practice for Describing and Measuring Performanceof Ultraviolet, Visible, and Near Infrared Spectrophotom-eters53. Terminology3.1 Definitions of Term Specific to This Standard:3.1.1 For definitions of terms used in these test methodsrefer to Terminology D 1129.3.2 Definitions of
9、 Terms Specific to This Standard:3.2.1 total recoverable arsenican arbitrary analytical termrelating to the forms of arsenic that are determinable by thedigestion method which is included in the procedure. Someorganic-arsenic compounds, such as phenylarsonic acid, diso-dium methane arsonate, and dim
10、ethylarsonic acid, are notrecovered completely during the digestion step.4. Significance and Use4.1 Herbicides, insecticides, and many industrial effluentscontain arsenic and are potential sources of water pollution.Arsenic is significant because of its adverse physiologicaleffects on humans.5. Puri
11、ty of Reagents5.1 Reagent grade chemicals shall be used in all tests.Unless otherwise indicated, it is intended that all reagents shallconform to the specifications of the Committee on AnalyticalReagents of the American Chemical Society, where suchspecifications are available.6Other grades may be us
12、ed, pro-vided it is first ascertained that the reagent is of sufficientlyhigh purity to permit its use without lessening the accuracy ofthe determination.1These test methods are under the jurisdiction of ASTM Committee D19 onWater and are the direct responsibility of Subcommittee D 19.05 on Inorgani
13、cConstituents in Water.Current edition approved Jan. 10, 2003. Published January 2003. Originallyapproved in 1993. Last previous edition approved in 1997 as D 2972 97.2Similar to that appearing in Standard Methods for the Examination of Waterand Wastewater, 12th edition, APHA, Inc., New York, NY, 19
14、65, and identical withthat in Brown, Eugene, Skougstad, M. W., and Fishman, M. J., “Methods forCollection and Analysis of Water Samples for Dissolved Minerals and Gases,”Techniques of Water-Resources Investigations of the U.S. Geological Survey, Book5, Chapter , 1970 p. 46.3Annual Book of ASTM Stand
15、ards, Vol 11.01.4Annual Book of ASTM Standards, Vol 03.05.5Annual Book of ASTM Standards, Vol 03.06.6Reagent Chemicals, American Chemical Society Specifications, AmericanChemical Society, Washington, DC. For suggestions on the testing of reagents notlisted by the American Chemical Society, see Anala
16、r Standards for LaboratoryChemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeiaand National Formulary, U.S. Pharmaceutical Convention, Inc. (USPC), Rockville,MD.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Dri
17、ve, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.2 Purity of Water Unless otherwise indicated, refer-ences to water shall be understood to mean reagent waterconforming to Specification D 1193 Type I. Other reagentwater types may be used provided it is first ascertained that thewate
18、r is of sufficiently high purity to permit its use withoutadversely affecting the bias and precision of the test method.Type II water was specified at the time of round robin testingof this test method.6. Sampling6.1 Collect the sample in accordance with Practices D 3370.6.2 Preserve the samples wit
19、h HNO3(sp gr 1.42) to a pH of2 or less immediately at the time of collection; normally about2 mL/L is required. If only dissolved arsenic is to be deter-mined, filter the sample through a 0.45-m membrane filterbefore acidification. The holding times for the samples may becalculated in accordance wit
20、h Practice D 4841.TEST METHOD ASILVERDIETHYLDITHIOCARBAMATE COLORIMETRIC7. Scope7.1 This test method covers the determination of dissolvedand total recoverable arsenic in most waters and waste watersin the range from 5 to 250 g/L of arsenic.7.2 The precision and bias data were obtained on reagentwat
21、er, river water, and process water. The information onprecision and bias may not apply to other waters. It is the usersresponsibility to ensure the validity of this test method forwaters of untested matrices.8. Summary of Test Method8.1 Organic arsenic-containing compounds are decomposedby adding su
22、lfuric and nitric acids and repeatedly evaporatingthe sample to fumes of sulfur trioxide. The arsenic (V) soproduced, together with inorganic arsenic originally present, issubsequently reduced to arsenic (III) by potassium iodide andstannous chloride, and finally to gaseous arsine by zinc inhydrochl
23、oric acid solution. The resulting mixture of gases ispassed through a scrubber containing borosilicate wool im-pregnated with lead acetate solution and then into an absorp-tion tube containing a solution of silver diethyldithiocarbamatein pyridine. Arsine reacts with this reagent to form a red-color
24、ed silver sol having maximum absorbance at about 540nm. The absorbance of the solution is measured photometri-cally and the arsenic determined by reference to an analyticalcurve prepared from standards.9. Interferences9.1 Although many samples are relatively free of interfer-ences, several metals, n
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD29722003STANDARDTESTMETHODSFORARSENICINWATER 水中 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-513864.html