ASTM D2961-2011 Standard Test Method for Single-Stage Total Moisture Less than 15% in Coal Reduced to 2 36-mm (No 8 Sieve) Topsize《(8号)2 36 mm顶筛煤中单级总湿度低于15%的标准试验方法》.pdf
《ASTM D2961-2011 Standard Test Method for Single-Stage Total Moisture Less than 15% in Coal Reduced to 2 36-mm (No 8 Sieve) Topsize《(8号)2 36 mm顶筛煤中单级总湿度低于15%的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2961-2011 Standard Test Method for Single-Stage Total Moisture Less than 15% in Coal Reduced to 2 36-mm (No 8 Sieve) Topsize《(8号)2 36 mm顶筛煤中单级总湿度低于15%的标准试验方法》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D2961 11Standard Test Method forSingle-Stage Total Moisture Less than 15 % in CoalReduced to 2.36-mm (No. 8 Sieve) Topsize1This standard is issued under the fixed designation D2961; the number immediately following the designation indicates the year oforiginal adoption or, in the case o
2、f revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers a single-stage procedure for thedetermination of total moisture less t
3、han 15 % in coal reducedto 2.36- mm (No. 8 sieve) topsize. This test method is fordetermination of total moisture only. Materials subjected to thistest shall not be used in the determination of other testparameters. It is recognized that the conditions of the test canincrease the potential for signi
4、ficant oxidation effects on somecoals. If the oxidation potential is of concern, the use of thissingle-stage method shall involve prior agreement between theparties involved. This test method shall not be construed as thereferee standard test method for total moisture. For refereepurposes, users of
5、this test method are referred to Test MethodD3302 for moisture determination methods which are not assusceptible to oxidation effects.1.2 Statistical analysis of data from several sources indi-cates that at a 95% confidence level, there is statistically nosignificant difference between the mean valu
6、e of the resultsobtained by D2961 and D3302 (that is, no bias is detectedbetween the two methods at the 95% confidence level) formoisture levels between 1.4% and 15.8%. These two testmethods were not compared in this study for some ranks ofcoal including lignite and anthracite. (See 10.2.)1.3 The va
7、lues stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate s
8、afety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D121 Terminology of Coal and CokeD2013 Practice for Preparing Coal Samples for AnalysisD3302 Test Method for Total Moisture in Coal3. Terminology3.1 Definitio
9、nsFor additional definitions of terms used inthis test method, refer to Terminology D121.4. Summary of Test Method4.1 Moisture is determined by establishing the weight lossof the coal sample by drying in an oven with forced-aircirculation.5. Significance and Use5.1 The measurement of total moisture
10、is required to deter-mine whether coal meets commercial or environmental speci-fications, or both. Within the limitations prescribed in thescope, this test method describes a procedure for determinationof total moisture that requires less time than the proceduresdescribed in Test Method D3302.6. App
11、aratus6.1 Drying Pans, noncorrodible, stable at the temperatureused, and of such size that the sample can be spread to a depthof not more than 25 mm (1 in.).6.1.1 The pan size may be varied to suit the size of thesample and the oven. The height of the sides shall be no morethan 40 mm (112 in.) so th
12、at air is not restricted in passing overthe coal.6.2 Drying Oven, forced air-type capable of maintaining atemperature of 107 6 3C and constructed to provide for acontinuous air flow to all parts of the oven. Air changes shallbe at the rate of two to four volumes per minute.1This test method is under
13、 the jurisdiction of ASTM Committee D05 on Coaland Coke and is the direct responsibility of Subcommittee D05.21 on Methods ofAnalysis.Current edition approved Nov. 1, 2011. Published December 2011. Originallyapproved in 1971. Last previous edition approved in 2007 as D2961 02(2007).DOI: 10.1520/D296
14、1-11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD29612011STANDARDTESTMETHODFORSINGLESTAGETOTALMOISTURELESSTHAN15INCOALREDUCEDTO236MMNO8SIEVETOPSIZE8

链接地址:http://www.mydoc123.com/p-513849.html