ASTM D2961 D2961M-2017 Standard Test Method for Single-Stage Total Moisture Less than 15 % in Coal Reduced to 2 36-mm (No 8 Sieve) Topsize 《(8号)2 36毫米顶筛煤中单级总湿度低于15%的标准试验方法》.pdf
《ASTM D2961 D2961M-2017 Standard Test Method for Single-Stage Total Moisture Less than 15 % in Coal Reduced to 2 36-mm (No 8 Sieve) Topsize 《(8号)2 36毫米顶筛煤中单级总湿度低于15%的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2961 D2961M-2017 Standard Test Method for Single-Stage Total Moisture Less than 15 % in Coal Reduced to 2 36-mm (No 8 Sieve) Topsize 《(8号)2 36毫米顶筛煤中单级总湿度低于15%的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D2961 11D2961/D2961M 17Standard Test Method forSingle-Stage Total Moisture Less than 15 % in CoalReduced to 2.36-mm (No. 8 Sieve) Topsize 1This standard is issued under the fixed designation D2961;D2961/D2961M; the number immediately following the designation indicatesthe year of origin
2、al adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope Scope*1.1 This test method covers a single-stage procedure for the d
3、etermination of total moisture less than 15 % in coal reduced to2.36- mm 2.36-mm (No. 8 sieve) topsize. This test method is for determination of total moisture only. Materials subjected to thistest shall not be used in the determination of other test parameters. It is recognized that the conditions
4、of the test can increase thepotential for significant oxidation effects on some coals. If the oxidation potential is of concern, the use of this single-stage methodshall involve prior agreement between the parties involved. This test method shall not be construed as the referee standard testmethod f
5、or total moisture. For referee purposes, users of this test method are referred to Test Method D3302 for moisturedetermination methods which are not as susceptible to oxidation effects.1.2 Statistical analysis of data from several sources indicates that at a 95% confidence level, there is statistica
6、lly no significantdifference between the mean value of the results obtained by D2961 and D3302 (that is, no bias is detected between the twomethods at the 95% confidence level) for moisture levels between 1.4% and 15.8%. These two test methods were not comparedin this study for some ranks of coal in
7、cluding lignite and anthracite. (See 10.211.2.)1.3 The values stated in either SI units or inch-pound units are to be regarded as standard. No other units of measurement areincluded in this standard. separately as standard. The values stated in each system may not be exact equivalents; therefore, ea
8、chsystem shall be used independently of the other. Combining values from the two systems may result in non-conformance with thestandard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to e
9、stablish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D121 Terminology of Coal and CokeD2013 Practice for Preparing Coal Samples for AnalysisD3302 Test Method for Total Moisture in Coal3. Term
10、inology3.1 DefinitionsFor additional definitions of terms used in this test method, refer to Terminology D121.4. Summary of Test Method4.1 Moisture is determined by establishing the weight loss of the coal sample by drying in an oven with forced-air circulation.5. Significance and Use5.1 The measure
11、ment of total moisture is required to determine whether coal meets commercial or environmental specifications,or both. Within the limitations prescribed in the scope, this test method describes a procedure for determination of total moisturethat requires less time than the procedures described in Te
12、st Method D3302.1 This test method is under the jurisdiction of ASTM Committee D05 on Coal and Coke and is the direct responsibility of Subcommittee D05.21 on Methods of Analysis.Current edition approved Nov. 1, 2011Feb. 1, 2017. Published December 2011February 2017. Originally approved in 1971. Las
13、t previous edition approved in 20072011as D2961 02D2961 11.(2007). DOI: 10.1520/D2961-11.10.1520/D2961_D2961M-17.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the
14、standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accu
15、rately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor
16、 Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States16. Apparatus6.1 Drying Pans, noncorrodible, stable at the temperature used, and of such size that the sample can be spread to a depth ofnot more than 25 mm (1 in.).1 in.6.1.1 The pan size may be varied to suit the size of the sampl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD2961D2961M2017STANDARDTESTMETHODFORSINGLESTAGETOTALMOISTURELESSTHAN15INCOALREDUCEDTO236MMNO8SIEVETOPSIZE8

链接地址:http://www.mydoc123.com/p-513847.html