1、Designation: D2829 07 (Reapproved 2013)Standard Practice forSampling and Analysis of Existing Built-Up Roof Systems1This standard is issued under the fixed designation D2829; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year
2、 of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice is a guide for removing test specimensfrom existing built-up roofing systems in the field and fordet
3、ermining the approximate quantities of the components ofthat specimen (Note 1). Components determined may be:1.1.1 Insulation components when they are part of the roofmembrane system,1.1.2 Plies of roofing felt,1.1.3 Interply layers of bituminous material,1.1.4 Top coating, and1.1.5 Surfacing.NOTE 1
4、This procedure is for the investigation of existing roofs and isnot intended for new construction inspection.1.2 This practice is applicable to both 914-mm (36-in.) and1000-mm (3938-in.) wide felt rolls.1.3 The values stated in SI (metric) units are to be regardedas standard.1.4 This standard does n
5、ot purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user this standard to establish appropriatesafety and health practices and determine the applicability ofregulatory limitations prior to use. For specific precautionaryinformation, see 6.
6、3.2.1.2. Referenced Documents2.1 ASTM Standards:2D226 Specification for Asphalt-Saturated Organic Felt Usedin Roofing and WaterproofingD227 Specification for Coal-Tar-Saturated Organic FeltUsed in Roofing and WaterproofingD249 Specification for Asphalt Roll Roofing (Organic Felt)Surfaced with Minera
7、l Granules (Withdrawn 2002)3D250 Standard Specification for Asphalt-Saturated AsbestosFelt Used in Roofing and Waterproofing (Withdrawn1991)3D371 Specification for Asphalt Roll Roofing (Organic Felt)Surfaced with Mineral Granules; Wide Selvage (With-drawn 2002)3D1079 Terminology Relating to Roofing
8、and WaterproofingD2178 Specification for Asphalt Glass Felt Used in Roofingand Waterproofing (Withdrawn 2013)3D2626 Specification for Asphalt-Saturated and Coated Or-ganic Felt Base Sheet Used in RoofingD3158 Specification for Asphalt Saturated and Coated Or-ganic Felt Used in Roofing (Withdrawn 198
9、3)3D3617 Practice for Sampling and Analysis of Built-Up RoofSystems During ApplicationD3672 Standard Specification for Venting Asphalt-Saturatedand Coated Inorganic Felt Base Sheet Used in Roofing(Withdrawn 1990)3D3909 Specification for Asphalt Roll Roofing (Glass Felt)Surfaced With Mineral Granules
10、D4601 Specification for Asphalt-Coated Glass Fiber BaseSheet Used in RoofingD4897 Specification forAsphalt-Coated Glass-Fiber VentingBase Sheet Used in RoofingD4990 Specification for Coal Tar Glass Felt Used in Roofingand Waterproofing3. Terminology3.1 DefinitionsFor definitions of terms used in thi
11、spractice, refer to Terminology D1079.4. Securing of Specimens in the Field4.1 Do not disturb any surfacing in the area from which aspecimen is to be taken. Cut each specimen at least 300 by 300mm (12 by 12 in.) and use the total specimen taken in the fieldfor laboratory analysis.4.2 The recommended
12、 practice is to use a cutting template(Fig. 1) consisting of a 300 by 300-mm (12 by 12-in.) metalbox with an open bottom. Place the box over the roof area that1This practice is under the jurisdiction ofASTM Committee D08 on Roofing andWaterproofing and is the direct responsibility of Subcommittee D0
13、8.20 on RoofingMembrane Systems.Current edition approved May 1, 2013. Published May 2013. Originallyapproved in 1969. Last previous edition approved in 2007 as D2829 07. DOI:10.1520/D2829-07R13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at s
14、erviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken
15、, PA 19428-2959. United States1is to be removed, and while the template is held firmly inposition, remove the surfacing around the perimeter and thencut through the roof membrane around the perimeter of thebox. Lift the specimen, including all associated loose materials,from the roof and place it in
16、 a plastic bag. Fully identify thespecimen. Note if the insulation is adhered to the specimen or,where insulation is not used, if bitumen is left on the deck, andthe type of deck. Estimate bitumen mass per unit area left onthe deck.4.2.1 Alternate Method:4.2.1.1 Mark each sample as at least a square
17、 356 mm (14in.) on a side. Try to include a seam in each membrane sample.During cold weather, use a square 457 mm (18 in.) on a side,since cold weather cutting may inadvertently break, distort ordelaminate the sample. If the roofing membrane is mechani-cally fastened, mark rectangular 864 by 457 mm
18、(34 by 18 in.)sample, with the longer dimension perpendicular to the lengthof the ply felts. Half of these large samples can be shipped tothe laboratory for analysis after the number of fasteners in thelarger area is recorded.4.2.1.2 Carefully broom off the loose aggregate, and spudoff the adhered a
19、ggregate and flood coating at the perimeter ofthe sample. (The application of dry ice at the areas to bespudded will ease the removal of the top coating during hotweather. A large propane torch can also be used as an alternateto the dry ice method, to melt the top coating so that it can beeasily rem
20、oved with a scraper and facilitate cutting.) Recordthe length and width of the sample. If the quantities ofunadhered surfacing or total surfacing are desired, collect andpackage the unadhered surfacing from the sample area.4.2.1.3 Cut through the roofing membrane with a razor knifeor sharp power cut
21、ting tool, taking care not to damage the edgeof the sample. Do not pound on the sample, as this might causeinterply delamination. Carefully loosen and remove the roofingmembrane including all adhered insulation. Observe and re-cord the kind and degree of attachment between the roofingmembrane and th
22、e insulation or deck.4.2.1.4 Cut through the roof insulation with a blade longenough to penetrate all of the insulation layers. Observe andrecord the type and thickness of each insulation layer, and thepercent of the sample area adhered between the layers andbetween the insulation and the deck and v
23、apor retarder.4.2.1.5 Cut and remove a small specimen of the vaporretarder, if it is present, to observe its attachment to the deckand to obtain a specimen for moisture content and analysis.NOTE 2This procedure will not provide as accurate a measure of totalaggregate as the procedure described in 4.
24、2.4.3 If bituminous material has been absorbed by the insu-lation (4.2), remove sufficient insulation to allow laboratoryanalysis of absorbed bitumen mass (weight).4.4 If felt lapping is to be determined, take a separatespecimen at least 100 mm (4 in.) wide and not less than 1.12 m(44 in.) long, cut
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD282920072013STANDARDPRACTICEFORSAMPLINGANDANALYSISOFEXISTINGBUILTUPROOFSYSTEMS 现有 组合 屋顶 系统 取样 分析

链接地址:http://www.mydoc123.com/p-513584.html