ASTM D2759-2000(2005) Standard Practice for Sampling Gas from a Transformer Under Positive Pressure《在正压力下从变压器中抽取气体样品的标准实施规程》.pdf
《ASTM D2759-2000(2005) Standard Practice for Sampling Gas from a Transformer Under Positive Pressure《在正压力下从变压器中抽取气体样品的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2759-2000(2005) Standard Practice for Sampling Gas from a Transformer Under Positive Pressure《在正压力下从变压器中抽取气体样品的标准实施规程》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 2759 00 (Reapproved 2005)Standard Practice forSampling Gas from a Transformer Under Positive Pressure1This standard is issued under the fixed designation D 2759; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the ye
2、ar of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the sampling of gas above theinsulating liquid of a transformer. A gas sampling bottlecoll
3、ects the gas sample from the gas space that is at a positivepressure.1.2 Representative samples of gas are taken for analysis todetermine their compositions.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 This standard d
4、oes not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Significance and Use2.1 A gas s
5、ample from above the insulating liquid intransformers and other electrical power apparatus can be usedto give an early indication of developing fault conditions.Combustible gases are formed from the breakdown of theinsulating materials under thermal and electrical stress. Exces-sive concentrations o
6、f combustible gases indicate the need totake appropriate action.2.2 It is important that gas samples from equipment be takenfrom the gas space directly above the liquid level, and not fromremote expansion compartments, such as tank bracing bands.2.3 The procedure described should be carefully follow
7、ed toensure that the sample is not diluted by air or nitrogen, orcontaminated by residual materials in the sampling bottle.3. Apparatus3.1 Gas Sampling Bottlestainless steel, Monel metal, orglass, of at least 250-cm3capacity, with a valve and a hoseconnector on each end.3.1.1 The gas sampling bottle
8、 must be free of dirt, moisture,oil, or other contaminants. It should be cleaned by washingwith anhydrous isopropyl alcohol, or other suitable cleaningagent that is free from residue upon evaporation. The bottleshould then be dried by blowing out with dry air or nitrogen,oven baking, or be dried und
9、er vacuum.3.2 Plastic BagThe bag should have only one openingarranged to fit over one of the hose connectors on the samplingbottle. The plastic bag should have a volume, when fullyexpanded, of approximately 15 times the volume of thesampling bottle.4. Procedure4.1 Before connecting the sampling bott
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD275920002005STANDARDPRACTICEFORSAMPLINGGASFROMATRANSFORMERUNDERPOSITIVEPRESSURE 压力 变压器 抽取 气体 样品

链接地址:http://www.mydoc123.com/p-513467.html