ASTM D2687-1995(2001) Standard Practices for Sampling Particulate Ion-Exchange Materials《粒状离子交换材料的取样的标准操作规程》.pdf
《ASTM D2687-1995(2001) Standard Practices for Sampling Particulate Ion-Exchange Materials《粒状离子交换材料的取样的标准操作规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2687-1995(2001) Standard Practices for Sampling Particulate Ion-Exchange Materials《粒状离子交换材料的取样的标准操作规程》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 2687 95 (Reapproved 2001)Standard Practices forSampling Particulate Ion-Exchange Materials1This standard is issued under the fixed designation D 2687; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 These practices2cover procedures for obtaining repre-sentative samples of ion-exchange materials. The followingpractices a
3、re included:SectionsPractice ASampling from a Single Package andMultiple Package Lots or Shipments 4 to 10Practice BSampling from Fixed Bed Ion-ExchangeEquipment Having Unrestricted Head Room 11 to 15Practice CSampling from Fixed Bed Ion-ExchangeEquipment Having Restricted Head Room 16 to 211.2 This
4、 standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents
5、2.1 ASTM Standards:D 1129 Terminology Relating to Water33. Terminology3.1 DefinitionsCertain terms in these practices that relateto ion exchange are defined in Terminology D 1129.PRACTICE ASAMPLING FROM A SINGLEPACKAGE AND MULTIPLE PACKAGE LOTS ORSHIPMENT4. Summary of Practice4.1 A hollow, sample-pr
6、obe guide that is comprised ofmating threaded sections and that can be extended to anyconvenient length by the addition of more sections, is insertedinto an ion-exchange unit. A sampling tube is inserted throughthe probe guide and is connected to a vacuum source. Ion-exchange material is removed by
7、eduction. A core sampler alsomay be used.5. Significance and Use5.1 This practice will be used most frequently to samplematerials as received from the manufacturer in the originalshipping container and prior to any resin-conditioning proce-dure. Since certain ion-exchange materials are supplied by t
8、hemanufacturer in the dry or free-flowing state whereas others aresupplied moist, it is necessary to employ two different sam-pling devices. Therefore, this practice is divided into SamplingProcedureDry or Free-Flowing Material, and SamplingProcedureMoist Material.5.2 Once the sample is obtained, it
9、 is necessary to protectthe ion-exchange materials from changes. Samples should beplaced in sealable, gasproof containers immediately.6. Apparatus6.1 Sampling Devices, as shown in Fig. 1 and Fig. 2.46.2 Sealable, Gasproof Containers, for sample storage.6.3 Sample Quartering MaterialsA 0.5 by 0.5 m (
10、20 by20 in.) sheet of glazed paper, oil cloth, or flexible plastic film.7. Kind and Number of Samples7.1 For a representative sample from a single package, aminimum of three probes or increments should be taken withthe sampling device.7.2 For a representative sample from a multiple package lotor shi
11、pment:7.2.1 If the markings on the package indicate the material tobe sampled is from a single lot (batch or manufacturing run),the number of packages selected shall be not less than 10 % ofthe packages received. When less than 30 packages arereceived, a minimum of three packages shall be chosen atr
12、andom for sampling. If a single lot contains more than 30packages and the order of filling is designated on the packages,the first, last, and middle packages shall be sampled. If theresults of the analysis of these three samples agree within thelimits of precision of the test methods used, further s
13、amplesfrom the lot need not be taken. If they are not in agreement,additional samples may be taken at the option of the partiesconcerned. When the entire shipment oran entire lot consists of1These practices are under the jurisdiction of ASTM Committee D19 on Waterand are the direct responsibility of
14、 Subcommittee D19.08 on Membranes and IonExchange Materials.Current edition approved April 15, 1995. Published June 1995. Originallypublished as D 2687 68 T. Last previous edition D 2687 84 (1990).2These practices were developed from activities withinASTM Committee D-19.3Annual Book of ASTM Standard
15、s, Vol 11.01.4The sampling device described in Fig. 2 is the same as that used in ASTMMethods C 183, Sampling Hydraulic Cement, Annual Book of ASTM Standards, Vol14.01.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.three packages or
16、 less, a sample shall be taken from eachpackage. The number of samples taken with the samplingdevice should not be less than three per individual package.7.2.2 If the shipment consists of more than one lot (batch ormanufacturing run) of material, sample each lot separately asin 7.2.1. For a represen
17、tative sample of the entire shipment, thenumber of packages sampled per lot should be in the same ratioas the number of packages of that lot in the entire shipment.For example, if the shipment consists of 40 drums of lot x and60 drums of lot y, sample four drums of lot x and six drums oflot y.8. Sam
18、pling ProcedureDry or Free-Flowing Material8.1 If the ion-exchange material is dry or free-flowing andcontained in a drum:8.1.1 Rock the drum slightly from several sides for uniformpacking and open.8.1.2 The points chosen for probing on the surface shouldlie on a circle approximately two thirds the
19、diameter of thedrum and uniformly spaced.8.1.3 Rotate the inner tube of the sampling device (Fig. 2)tothe closed position, and thrust the sampling device to thebottom of the drum.8.1.4 Rotate the inner tube to the open position and collectthe sample by moving the top of the sampling device in a circ
20、le(about 75 to 150 mm (3 to 6 in.) in diameter) several times withthe open sections forward.8.1.5 Rotate the inner tube to the closed position andremove the sampling device from the drum.NOTE 1The sharp point of the sampling device may pierce the drumliner. Have the point rounded slightly (by grindi
21、ng, filing, etc.).NOTE 2Corrosion may occur after only a few months on this type ofsampling device and will render it unsuitable for resin sampling.8.1.6 Empty the contents into the sample container.8.1.7 Repeat 8.1.3 through 8.1.6 until sufficient sample isobtained.Aminimum of three probes or incre
22、ments is required.If the sample obtained is larger than required, reduce thesample using the quartering techniques given in 10.1.8.1.8 Seal the sample container and affix label as outlined inSection 11.8.1.9 Alternatively, the sampling tube (Fig. 1) may be usedfor sampling dry or free-flowing resin.
23、 Follow procedure givenin Section 9. Loss of resin from the bottom of the sampler mayoccur and cause bias in the sample.8.2 If the ion-exchange material is dry or free-flowing andthe outer package is a bag:8.2.1 Transfer the contents of the bag to a drum which hasa diameter less than its height and
24、will hold the entire contentsof the bag.8.2.2 Proceed in accordance with 8.1.NOTE 3The sampling device (Fig. 2) can allow resin entering theupper openings to fall into the bottom portion of the device, therebybiasing the sample.9. Sampling ProcedureMoist Material9.1 If the ion-exchange material is m
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD268719952001STANDARDPRACTICESFORSAMPLINGPARTICULATEIONEXCHANGEMATERIALS 粒状 离子交换 材料 取样 标准 操作规程 PDF

链接地址:http://www.mydoc123.com/p-513318.html