1、Designation: D 2659 95 (Reapproved 2005)Standard Test Method forColumn Crush Properties of Blown ThermoplasticContainers1This standard is issued under the fixed designation D 2659; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, th
2、e year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of mechanicalproperties of blown thermoplastic containers when lo
3、adedunder columnar crush conditions at a constant rate of compres-sive deflection. Any container, whether blown commercially orin the laboratory, may be used as the test specimen.1.2 The values stated in SI units are to be regarded as thestandard.NOTE 1There is no similar or equivalent ISO standard.
4、1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced D
5、ocuments2.1 ASTM Standards:2D 618 Practice for Conditioning Plastics for TestingD 4976 Specification for Polyethylene Plastics Molding andExtrusion MaterialsE4 Practices for Force Verification of Testing MachinesE83 Practice for Verification and Classification of Exten-someters3. Terminology3.1 Defi
6、nitions:3.1.1 crushing yield loadthe first load at which an in-crease of deflection occurs with no increase in load in acompressive crushing test. It is expressed in units of kilograms(or pounds) of load.NOTE 2In some cases, usually as a result of design or styling features,or both, of a specific co
7、ntainer, multiple values of the crushing yield loadmay be observed, a small deflection may occur with no increase or witha decrease in the crush load, followed by resumption of the normal crushload change with deflection. This phenomenon cannot be ignored in theevaluation of the column crush propert
8、ies of a blown thermoplasticcontainer, since it may be a very useful designated failure point for theapplication under consideration. The load at which this abrupt changeoccurs may be chosen as a crushing yield load for study. In such a case,the report of results should be accompanied by a proper de
9、scription of thecrushing yield load selected.3.1.2 crushing load at failurethe crushing load applied toa blown thermoplastic container that produces a failure byfracture or parting of the material in any portion of saidcontainer. It is expressed in kilograms (or pounds).3.1.3 deflection at crushing
10、yield loadthe decrease inlength of the container specimen produced at the crushing yieldload along the center line of testing (axis of crushing, see Fig.1). It is expressed in millimetres (or inches).3.1.4 apparent crushing stiffnessthe ratio of the crushingload to the corresponding deflection at a
11、point on the linearportion of the crushing load deflection curve. It is expressed innewtons per metre (or pounds per inch).4. Significance and Use4.1 Column crush tests provide information about the crush-ing properties of blown thermoplastic containers when em-ployed under conditions approximating
12、those under which thetests are made.4.2 The column crush properties include the crushing yieldload, deflection at crushing yield load, crushing load at failure,and apparent crushing stiffness. Blown thermoplastic contain-ers made from materials that possess a low order of ductilitymay fail in crushi
13、ng by brittle fracture. In such cases, thecrushing yield load is equivalent to the crushing load at failure.Blown thermoplastic containers made of ductile materials maynot exhibit a crushing load at failure although they willnormally provide a crushing yield load value.4.3 Column crush tests provide
14、 a standard method ofobtaining data for research and development, applications,design, quality control, acceptance or rejection under specifi-cations, and special purposes. The tests cannot be consideredsignificant for engineering design in applications differingwidely from the load - time scale of
15、the standard test. Suchapplications require additional tests such as impact, creep, andfatigue.1This test method is under the jurisdiction of ASTM Committee D20 on Plasticsand is the direct responsibility of Subcommittee D20.20 on Plastic Products.Current edition approved July 15, 2005. Published Au
16、gust 2005. Originallyapproved in 1967. Last previous edition approved in 2001 as D 2659 - 1995 (2001).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards
17、Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.4 Before proceeding with this test method, referenceshould be made to the specification of the material being tested.Any test specimen prepara
18、tion, conditioning, dimensions, ortesting parameters, or combination thereof, covered in thematerials specification shall take precedence over those men-tioned in this test method. If there are no material specifica-tions, then the default conditions apply.5. Apparatus5.1 Testing MachineAny suitable
19、 testing machine capableof control of constant-rate-of-crosshead movement and com-prising essentially the following:5.1.1 Drive MechanismA drive mechanism imparting thecrosshead movable member of a uniform, controlled velocitywith respect to the fixed member, this velocity to be regulatedas specifie
20、d in Section 9.5.1.2 Load IndicatorA load-indicating mechanism ca-pable of showing the total crushing load carried by the testspecimen. The mechanism shall be essentially free frominertia-lag at the specified rate of testing and shall indicate thecrushing load with an accuracy of 61 %. The accuracy
21、of thetesting machine shall be verified at least once a year, inaccordance with Practices E4.5.2 ExtensometerA suitable instrument for determiningthe distance between the two surfaces of load application onthe test specimen at any time during the test. It is desirable thatthis instrument automatical
22、ly record this distance, or anychange in it as a function of the crushing load on the testspecimen. The instrument shall be essentially free of inertia-lagat the specified rate of loading and shall conform to therequirements for a Class B-2 extensometer, as defined inPractice E83.6. Test Specimens6.
23、1 The specimens for testing shall be the blown thermo-plastic container under investigation. The specimens must befree of obvious defects such as rocker bottoms or bent necks,unless such defects constitute a variable to be studied. Thesurfaces of the container that bear on the fixed and movablemembe
24、rs of the testing machine shall be parallel to each other.NOTE 3In the event that the bearing surface of the blown thermo-plastic container deviates noticeably from the parallel relationship, theconstruction and use of a suitable testing jig will be necessary. This jigshall be attached to that cross
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD265919952005STANDARDTESTMETHODFORCOLUMNCRUSHPROPERTIESOFBLOWNTHERMOPLASTICCONTAINERS 制热 容器 圆筒 压碎

链接地址:http://www.mydoc123.com/p-513261.html