ASTM D2609-2002 Standard Specification for Plastic Insert Fittings for Polyethylene (PE) Plastic Pipe《聚乙烯(PE)塑料管用塑料制插入式配件的标准规范》.pdf
《ASTM D2609-2002 Standard Specification for Plastic Insert Fittings for Polyethylene (PE) Plastic Pipe《聚乙烯(PE)塑料管用塑料制插入式配件的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2609-2002 Standard Specification for Plastic Insert Fittings for Polyethylene (PE) Plastic Pipe《聚乙烯(PE)塑料管用塑料制插入式配件的标准规范》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 2609 02An American National StandardStandard Specification forPlastic Insert Fittings for Polyethylene (PE) Plastic Pipe1This standard is issued under the fixed designation D 2609; the number immediately following the designation indicates the year oforiginal adoption or, in the case
2、of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This specif
3、ication covers plastic insert fittings for poly-ethylene (PE) plastic pipe. Included are requirements formaterials, workmanship, dimensions, and burst pressure.1.2 The text of this specification references notes, footnotes,and appendixes which provide explanatory material. Thesenotes and footnotes (
4、excluding those in tables and figures) shallnot be considered as requirements of the specification.1.3 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are providedfor information only.1.4 The following safety hazards caveat pertains only tothe
5、 test methods portion, Section 8, of this specification: Thisstandard does not purport to address all of the safety concerns,if any, associated with its use. It is the responsibility of the userof this standard to establish appropriate safety and healthpractices and determine the applicability of re
6、gulatory limita-tions prior to use.2. Referenced Documents2.1 ASTM Standards:D 256 Test Methods for Determining the Izod PendulumImpact Resistance of Plastics2D 618 Practice for Conditioning Plastics for Testing2D 638 Test Method for Tensile Properties of Plastics2D 648 Test Method for Deflection Te
7、mperature of PlasticsUnder Flexural Load in the Edgewise Position2D 789 Test Methods for Determination of Relative Viscos-ity and Moisture Content of Polyamide (PA)2D 1599 Test Method for Resistance to Short-Time Hydrau-lic Failure Pressure of Plastic Pipe, Tubing, and Fittings3D 1600 Terminology fo
8、r Abbreviated Terms Relating toPlastics2D 1784 Specification for Rigid Poly(Vinyl Chloride) (PVC)Compounds and Chlorinated Poly(Vinyl Chloride)(CPVC) Compounds2D 2104 Specification for Polyethylene (PE) Plastic Pipe,Schedule 403D 2239 Specification for Polyethylene (PE) Plastic Pipe(SIDR-PR) Based o
9、n Controlled Inside Diameter3F 412 Terminology Relating to Plastic Piping Systems3F 1498 Specification for Taper Pipe Threads 60 for Ther-moplastic Pipe and Fittings32.2 NSF Standards:Standard No. 14 for Plastic Piping Components and RelatedMaterials4Standard No. 61 for Drinking Water System Compone
10、ntsHealth Effects43. Terminology3.1 Definitions are in accordance with Terminology F 412and abbreviations are in accordance with Terminology D 1600,unless otherwise specified.4. Classification4.1 This specification covers one class of fittings suitable foruse with PE plastic pipe that meet the requi
11、rements ofapplicable ASTM specifications. At present, these are Specifi-cations D 2104 and D 2239.5. Materials5.1 Types of PlasticsThe fittings shall be made from oneof the following plastics:5.1.1 Nylon plastics (NP) meeting the requirements ofeither Type I or Type II (except Grade 2A) in Test Meth
12、odsD 789.5.1.2 Propylene plastic (PP) with a minimum tensilestrength at yield of 24.0 MPa (3410 psi) when tested inaccordance with Test Method D 638 at a speed of 51 mm/min(2.0 in./min), an Izod impact resistance at 23C of at least 30J/m (0.6 ftlbf/in.) when tested in accordance with Method Aof Test
13、 Methods D 256, and a minimum deflection temperatureof 64C at 455 KPa stress when tested in accordance with TestMethod D 648.1This specification is under the jurisdiction of ASTM Committee F17 on PlasticPiping Systems and is the direct responsibility of Subcommittee F17.10 on Fittings.Current editio
14、n approved September 10, 2002. Published September 2002.Originally published as D 2609 67. Last previous edition D 2609 00.2Annual Book of ASTM Standards, Vol 08.01.3Annual Book of ASTM Standards, Vol 08.04.4Available from the National Sanitation Foundation, P.O. Box 1468, Ann Arbor,MI 48106.1Copyri
15、ght ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.1.3 Poly(vinyl chloride) plastics (PVC) meeting the re-quirements of 12454-B, 12454-C, 11443-B, or 14333-D, inSpecification D 1784.5.2 Rework MaterialThe manufacturers shall use onlytheir ow
16、n clean rework fitting material and the fittings pro-duced shall meet all the requirements of this specification. Thetypes of materials specified in 5.1 shall not be mixed with oneanother.6. Requirements6.1 Dimensions and TolerancesThe dimensions and tol-erances shall be as shown in Tables 1-3 when
17、measured inaccordance with 8.4. The negative tolerance on all minimumdimensions is zero.6.1.1 AlignmentThe alignment of all openings of fittingsshall be within14in./ft.6.1.2 Fittings Not IllustratedAll fittings, whether illus-trated in Tables 1-3 or not, shall have insert ends in accordancewith Tabl
18、e 1 or threaded ends in accordance with Table 3. Forinsert ends, which have more than four barbs, the first fourbarbs, starting from the open end of the fitting connection, shallmeet all requirements of Table 1. The remaining barbs shallalso meet Table 1, with the exception that mold marks left asa
19、result of the manufacturing process, such as ejector pinmarks, are exempt from the “V” dimension requirement, andthe minimum requirement for “Z.” D, Zmax, and F apply in allcases. For designs where the entire fitting end is barbed, suchas “F” cannot be readily measured, “F” shall be calculated as(Z2
20、V)D/2.6.1.3 ThreadsFor all fittings having taper pipe threads,threads shall conform to Specification F 1498 and be gaged inaccordance with 8.6.6.2 Burst PressureThe minimum burst pressure for thefittings shall be as shown in Table 4, when determined inaccordance with 8.5.7. Workmanship, Finish, and
21、Appearance7.1 The fittings shall be homogeneous throughout and freeof cracks, holes, foreign inclusions, or other defects. Thefittings shall be as uniform as commercially practicable incolor, opacity, density, and other physical properties.8. Test Methods8.1 ConditioningCondition the specimens at 73
22、.4 6 3.6F(23 6 2C) and 50 6 5 % relative humidity for not less than 40TABLE 1 Dimensions of Insert End,Ain. (mm)NominalPipe SizeInsertLength, PBarbsDepth, VWallThickness,FInsideDiameter ofFitting, DLength,YOutside Diameter, ZBNumbermin min max min min min min min12 114 (31.8)34 (19.0) 0.665 (16.9) 0
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD26092002STANDARDSPECIFICATIONFORPLASTICINSERTFITTINGSFORPOLYETHYLENEPEPLASTICPIPE 聚乙烯 PE 塑料 管用 插入

链接地址:http://www.mydoc123.com/p-513158.html