《ASTM D2591-2007(2013) Standard Test Method for Linear Density of Elastomeric Yarns (Short Length Specimens)《弹性纱线性密度的标准试验方法(短长度试样)》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2591-2007(2013) Standard Test Method for Linear Density of Elastomeric Yarns (Short Length Specimens)《弹性纱线性密度的标准试验方法(短长度试样)》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D2591 07 (Reapproved 2013)Standard Test Method forLinear Density of Elastomeric Yarns (Short LengthSpecimens)1This standard is issued under the fixed designation D2591; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, t
2、he year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the lineardensity of short lengths of “as produced” elastomeri
3、c yarnsmade from rubber, spandex or other elastomers.NOTE 1For the determination of linear density of elastomeric yarnsusing skeins, refer to Test Method D6717.1.2 This test method is not applicable to covered, wrapped,or core-spun yarns, or yarns spun from elastomeric staple, orelastomeric yarns re
4、moved from fabrics.1.3 This test method is applicable to elastomeric yarnshaving a range of 40 to 3200 dtex (36 to 2900 denier).1.4 The values stated in either SI units or U.S. Customaryunits are to be regarded separately as standard. Within the testthe US Customary units are in parentheses. The val
5、ues stated ineach system are not exact equivalents; therefore, each systemshall be used independently of the other.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate
6、safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D123 Terminology Relating to TextilesD2258 Practice for Sampling Yarn for TestingD6717 Test Method for Linear Density of Elastomeric Yarns(Skein Specimens)D4
7、849 Terminology Related to Yarns and Fibers3. Terminology3.1 For all terminology relating to D13.58, Yarns andFibers, refer to Terminology D4849.3.1.1 The following terms are relevant to this standard:denier, elastomeric yarn, linear density, tex.3.2 For all other terminology related to textiles, re
8、fer toTerminology D123.4. Summary of Test Method4.1 A pre-relaxed specimen is fastened in verticallymounted apparatus under a specified tension.Aspecified lengthis cut from the specimen and weighed, and the linear densitycalculated.5. Significance and Use5.1 This test method is considered satisfacto
9、ry for accep-tance testing of commercial shipments because current esti-mates of between-laboratory precision are acceptable and themethod is used extensively in the trade for acceptance testing.5.1.1 If there are differences of practical significance be-tween reported test results for two laborator
10、ies (or more),comparative tests should be performed to determine if there isa statistical bias between them, using competent statisticalassistance. As a minimum, use samples for such comparativetests that are as homogeneous as possible, drawn from the samelot of material as the samples that resulted
11、 in disparate resultsduring initial testing, and randomly assigned in equal numbersto each laboratory. The test results from the laboratoriesinvolved should be compared using a statistical test forunpaired data, at a probability level chosen prior to the testingseries. If bias is found, either its c
12、ause must be found andcorrected, or future test results for that material must beadjusted in consideration of the known bias.5.2 Linear density of elastomeric yarns is used in somecalculations for tensile and elastic properties.5.3 The test method is based on elastomeric yarns in lthe“as-produced” c
13、ondition, but may be used for treated elasto-meric yarns provided the treatment is specified. The method1This test method is under the jurisdiction of ASTM Committee D13 on Textilesand is the direct responsibility of Subcommittee D13.58 on Yarns and Fibers.Current edition approved July 1, 2013. Publ
14、ished September 2013. Originallyapproved in 1967. Last previous edition approved in 2007 as D2591 07. DOI:10.1520/D2591-07R13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information,
15、 refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1does not cover the removal of finish for the determination oflinear density of “finish-free” elastomeric yarns.6. Apparat
16、us36.1 Specimen Boards, with short pile or plush surfaces ofblack or contrasting color, for storing specimens during relax-ation period.6.2 Linear Density Apparatus, mounted vertically on a wallor in a sturdy, stable vertical support and containing theessential parts listed below. See Fig. 1 and Ann
17、ex A1 forgeneral construction details of suitable apparatus.6.2.1 Steel Plate, about 100 mm (4 in.) wide and 1.3 m (1.4yd) long.6.2.2 Clamps, three toggle-action type with rubber tips.6.2.3 Brass Plates, two, with slots at right angles to be usedfor controlling the alignment and length of the specim
18、en.6.2.3.1 The slots are positioned such that the distancebetween the slot midlines provides a gage length of 1000 mmwhen using the tex system or 900 mm when using the deniersystem. If necessary, the two gage lengths can be obtained byhaving the upper slot assembly adjustable, or by having twosepara
19、te test apparatuses.6.3 Tensioning Weights, with varioius masses from 10 mg to3 g as required, to pretension the specimens to 1.0 6 0.1 cN/tex(0.9 6 0.09 gf/d) tension based on the nominal linear densityof the yarn.6.4 Razor Blades, safety single-edge, or wood-carving typeknife.6.5 Balance, with an
20、accuracy of 6 0.1% of the expectedmass of the specimens.7. Sampling, Test Specimens, and Test Units7.1 Lot SampleAs a lot sample for acceptance testing, takea random number of shipping units directed in an applicable3Components are commercially available.NOTE 1Drawing not to scale. For conversion to
21、 U.S. customary units,divide mm by 25.4 to obtain inchesFIG. 1 Linear Density ApparatusD2591 07 (2013)2material specification or other agreement between the pur-chaser and the supplier, such as an agreement to use PracticeD2258. Consider shipping cases or other shipping units to bethe primary sampli
22、ng units.NOTE 2An adequate specification or other agreement between thepurchaser and the supplier requires taking into account the variabilitybetween shipping units, between packages or ends within a shipping unit,and between specimens from a single package to provide a sampling witha meaningful pro
23、ducers risk, consumers risk, acceptable quality leveland limiting quality level.7.2 Laboratory SampleAs a laboratory sample for accep-tance testing, take at random from each shipping unit in the lotsample the number of packages directed in an applicablematerial specification or other agreement betwe
24、en the pur-chaser and the supplier, such as an agreement to use PracticeD2258. Preferably, take the same number of packages fromeach of the shipping units selected. If differing numbers ofpackages are to be taken from the shipping units, determine atrandom which shipping units are to have each numbe
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD259120072013STANDARDTESTMETHODFORLINEARDENSITYOFELASTOMERICYARNSSHORTLENGTHSPECIMENS 弹性 纱线 密度 标准

链接地址:http://www.mydoc123.com/p-513134.html