1、Designation: D 2523 00 (Reapproved 2006)Standard Practice forTesting Load-Strain Properties of Roofing Membranes1This standard is issued under the fixed designation D 2523; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year o
2、f last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice is a guide for determining the load-strainproperties of roofing membranes and their components atvari
3、ous temperatures. Test specimens may be prepared in thelaboratory or cut from samples obtained in the field.1.2 The values stated in SI units are to be regarded as thestandard. The inch-pound units given in parentheses are forinformation only.1.3 This standard does not purport to address all of thes
4、afety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D95 Test Method for Water in
5、Petroleum Products andBituminous Materials by DistillationD 412 Test Methods for Vulcanized Rubber and Thermo-plastic ElastomersTensionE 178 Practice for Dealing With Outlying Observations3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 roofing membranethat part of the roofing
6、systemwhose primary function is to exclude water; it does not includefield-applied aggregate.4. Significance and Use4.1 This practice is designed to aid those interested in theengineering properties of roofing membranes.4.2 The data obtained will not permit prediction of theservice life of a membran
7、e under field conditions. The data willprovide a basis for study of the mechanical properties of themembrane. Note that if strain rates, specimen dimensions,initial clear distance between clamps, or temperatures andmoisture contents are varied, the data may not be strictlycomparable.5. Sampling5.1 T
8、ake field membrane sample at least 100 by 250 mm (4by 10 in.) in accordance with good roofing practices. In caseswhere field-applied aggregate is in place, remove it with ascraper such as a heated putty knife.5.1.1 Sample those areas of the membrane that are expectedto represent the extremes in load
9、/strain characteristics.5.1.2 At least one sample is required for each test tempera-ture at which it is desired to determine load/strain properties.5.2 Prepare laboratory samples at least 100 by 250 mm (4by 10 in.) in strict accordance with the roofing specificationbeing tested. Observe all cautions
10、 specified, such as notoverheating the bitumen. Do not oven condition any of thecomponents or the final sample.5.2.1 Select those areas of the membrane that are expectedto represent the extremes in load-strain characteristics. Prepareat least one sample of each type for each proposed testtemperature
11、. If there is any doubt about these areas, include allpossible variations. The samples must be uniform in crosssection.5.2.2 Select materials at random when possible. Compo-nents should be conditioned at 50 6 5 % relative humidity and25 6 2.5C (77 6 4.5F) for 24 h prior to constructingsamples.5.2.3
12、The quantity of material in any layer should be within610 %, and the entire sample should be within 65 % of thequantities specified.6. Test Specimens6.1 Condition the samples at room temperature at 50 6 5%relative humidity for a minimum of 16 h for non-solvent-containing membranes, and until constan
13、t mass has beenreached for solvent-containing membranes.6.2 Die-cut three tension test specimens from each sample.The shape of the specimens for membranes with less than 50 %ultimate elongation is shown in Fig. 1. Where the membranehas an ultimate elongation greater than 50 %, use Die C of TestMetho
14、ds D 412.1This practice is under the jurisdiction ofASTM Committee D08 on Roofing andWaterproofing and is the direct responsibility of Subcommittee D08.20 on RoofingMembrane Systems.Current edition approved May 1, 2006. Published May 2006. Originallyapproved in 1966. Last previous edition approved i
15、n 2000 as D 2523 00.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr H
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD252320002006STANDARDPRACTICEFORTESTINGLOADSTRAINPROPERTIESOFROOFINGMEMBRANES 屋顶 隔膜 荷载 应变 特性 试验 标准

链接地址:http://www.mydoc123.com/p-513036.html