ASTM D2504-1988(2015) Standard Test Method for Noncondensable Gases in C2 and Lighter Hydrocarbon Products by Gas Chromatography《采用气相色谱法测定C2和轻质烃类产品中不凝缩气体的标准试验方法》.pdf
《ASTM D2504-1988(2015) Standard Test Method for Noncondensable Gases in C2 and Lighter Hydrocarbon Products by Gas Chromatography《采用气相色谱法测定C2和轻质烃类产品中不凝缩气体的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2504-1988(2015) Standard Test Method for Noncondensable Gases in C2 and Lighter Hydrocarbon Products by Gas Chromatography《采用气相色谱法测定C2和轻质烃类产品中不凝缩气体的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D2504 88 (Reapproved 2015)Standard Test Method forNoncondensable Gases in C2and Lighter HydrocarbonProducts by Gas Chromatography1This standard is issued under the fixed designation D2504; the number immediately following the designation indicates the year oforiginal adoption or, in the
2、 case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of hydrogen,nitrogen, oxygen, and carbon mono
3、xide in the parts per millionvolume (ppmv) range in C2and lighter hydrocarbon products.This test method should be applicable to light hydrocarbonsother than ethylene, but the test program did not include them.1.2 The values stated in SI units are to be regarded as thestandard. The values given in pa
4、rentheses are for informationonly.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limita
5、tions prior to use. For some specifichazard statements, see the Annex A1.2. Referenced Documents2.1 ASTM Standards:2D2505 Test Method for Ethylene, Other Hydrocarbons, andCarbon Dioxide in High-Purity Ethylene by Gas Chroma-tographyE260 Practice for Packed Column Gas ChromatographyF307 Practice for
6、Sampling Pressurized Gas for Gas Analy-sis2.2 Other Standard:3Compressed Gas Association Booklets G-4 and G-4.1 on theuse of oxygen.3. Summary of Test Method3.1 The sample is separated in a gas-solid chromatographicsystem using molecular sieves as the solid adsorbent. Theconcentration of the gases t
7、o be determined is calculated fromthe recorded peak heights or peak areas. Argon can be used asa carrier gas for the determination of hydrogen in concentra-tions below 100 ppmv. Argon, if present in the sample,interferes with oxygen determination.4. Significance and Use4.1 The presence of trace amou
8、nts of hydrogen, oxygen, andcarbon monoxide can have deleterious effects in certain pro-cesses using hydrocarbon products as feed stock. This testmethod is suitable for setting specifications, for use as aninternal quality control tool and for use in development orresearch work.5. Apparatus5.1 Chrom
9、atographAny chromatographic instrumenthaving either a thermal conductivity or ionization detector withan overall sensitivity sufficient to detect 2 ppmv or less of thecompounds listed in the scope, with a peak height of at least2 mm without loss of resolution.5.2 DetectorsThermal ConductivityIf a me
10、thanation re-actor is used, a flame ionization detector is also required. Todetermine carbon monoxide with a flame ionization detector, amethanation reactor must be inserted between the column andthe detector and hydrogen added as a reduction gas. Details onthe preparation and use of the reactor are
11、 given in AppendixX1.5.3 Constant-Volume Gas Sampling Valve.5.4 ColumnAny column or set of columns that is capableof resolving the components listed in the scope can be used.Copper, stainless steel, or aluminum tubing may be used. Thecolumns chosen must afford a resolution such that the depth ofthe
12、valleys ahead of the trace peak is no less than 50 % of thetrace peak height.5.5 RecorderA recorder with a full-scale response of 2 sor less and a maximum rate of noise of 60.3 % of full scale.5.6 OvenThe oven used for activating molecular sievesmust be maintained at 260 C to 288 C (500 F to 550 F)
13、andshould be designed so that the gases may be displacedcontinuously by a stream of inert gas. The oven may be athermostated piece of 1 in. pipe about 0.3 m (1 ft) in length.1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products, Liquid Fuels, and Lubricants and is th
14、e direct responsibility ofSubcommittee D02.D0.02 on Ethylene.Current edition approved June 1, 2015. Published July 2015. Originally approvedin 1966. Last previous edition approved in 2010 as D2504 88 (2010). DOI:10.1520/D2504-88R15.2For referenced ASTM standards, visit the ASTM website, www.astm.org
15、, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Compressed Gas Association (CGA), 4221 Walney Rd., 5thFloor, Chantilly, VA 20151-2923, http:/.Copyright ASTM Inte
16、rnational, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1Electrical heating tapes or other means may be used for heatingprovided the heat is distributed uniformly.NOTE 1The use of copper tubing is not recommended with samplescontaining acetylene as this could le
17、ad to the formation of potentiallyexplosive copper acetylide.6. Reagents and Materials6.1 Molecular Sieves, 5A, 13A, or 13XAny mesh sizes canbe used so long as sensitivity and resolution are maintained(see Note 2). If a 40 mesh to 60 mesh sieve size is desired, butis not available, it may be prepare
18、d as described in 8.1.6.2 Coconut Charcoal, 30 mesh to 60 mesh sieve size (op-tional).NOTE 2Columns that have been found to give the desired separationinclude a 1 m by 3.175 mm outside diameter column of 100 mesh to120 mesh 5Amolecular sieve, a 3 m by 6.35 mm outside diameter columnof 40 mesh to 60
19、mesh 5Asieve, and a 7.7 m by 6.35 mm outside diametercolumn with 13Aor 13X sieve in the first 7.4 m and charcoal in the 0.3 m.6.3 Gases for CalibrationPure or research gradehydrogen, oxygen, nitrogen, and carbon monoxide will beneeded to prepare synthetic standard samples as described inTest Method
20、D2505.(WarningFlammable gases. Hazardouspressure. See Annexes A1.1 A1.5.) (WarningFlammable.Poison. Harmful if inhaled. Dangerous when exposed to flame.See Annex A1.5.) (WarningHazardous pressure. See AnnexA1.2.) Certified calibration blends are commercially availablefrom numerous sources and can be
21、 used as the syntheticstandard samples.6.4 Carrier GasesArgon or helium.NOTE 3Practice E260 contains information that will be helpful tothose using this test method.7. Sampling7.1 Samples shall be supplied to the laboratory in high-pressure sample cylinders, obtained using the proceduresdescribed in
22、 Practice F307 or similar methods.8. Preparation of Apparatus8.1 Chromatographic Column PackingCrush in a porce-lain mortar and sieve to 40 mesh to 60 mesh size about 200 gof molecular sieves 5A in order to have enough for severalcolumns. All work of preparing molecular sieves and packingcolumns wit
23、h this material shall be done rapidly, preferablyunder a blanket of dry nitrogen in order to minimize moistureabsorption. Heat the screened molecular sieves in an oven at274 C 6 14 C (525 F 6 25 F) for 24 h purging with drynitrogen at a rate of about 5 mL/min during this time. Thenitrogen rate is no
24、t critical and can be measured by anyconvenient means such as an orifice meter, rotameter,manometer, etc. Do not use a wet test meter.8.2 Chromatographic ColumnPurge the metal tubing withdry nitrogen. Insert a small amount of glass wool in the end.Fill rapidly with the screened and activated molecul
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD250419882015STANDARDTESTMETHODFORNONCONDENSABLEGASESINC2ANDLIGHTERHYDROCARBONPRODUCTSBYGASCHROMATOGRAPHY

链接地址:http://www.mydoc123.com/p-512986.html