ASTM D2448-1985(2012) Standard Test Method for Water-Soluble Salts in Pigments by Measuring the Specific Resistance of the Leachate of the Pigment《用测量颜料浸出液电阻率法测定颜料中水溶性盐的标准试验方法》.pdf
《ASTM D2448-1985(2012) Standard Test Method for Water-Soluble Salts in Pigments by Measuring the Specific Resistance of the Leachate of the Pigment《用测量颜料浸出液电阻率法测定颜料中水溶性盐的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2448-1985(2012) Standard Test Method for Water-Soluble Salts in Pigments by Measuring the Specific Resistance of the Leachate of the Pigment《用测量颜料浸出液电阻率法测定颜料中水溶性盐的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D2448 85 (Reapproved 2012)Standard Test Method forWater-Soluble Salts in Pigments by Measuring the SpecificResistance of the Leachate of the Pigment1This standard is issued under the fixed designation D2448; the number immediately following the designation indicates the year oforiginal
2、adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the specificresistance
3、of the aqueous leachate from a pigment as an indexof water-soluble salt content. This test method is applicable towhite pigments and colored pigments (organic and inorganic).The water-soluble salts content is a function of the specificresistance of the solution formed by extracting the pigmentwith w
4、ater.1.2 This test method is based on a water to pigment ratio of9+1. The leachate yield (minimum 160 mL) sufficient forrinsing the cylinder dip cell and thermometer plus the mini-mum 80 mL required for the measurement to determine thequantity of pigment to be used.1.3 The values stated in SI units
5、are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practic
6、es and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent Water3. Summary of Test Method3.1 A weighed quantity of pigment is added to water andboiled. For hydrophobic pigments methyl alcohol is used tofacilit
7、ate wetting. After filtration, the specific resistance of thefiltrate is determined using a conductivity bridge.4. Significance and Use4.1 This test method provides a reliable means for thedetermination of the relative amounts of these salts whencomparing different lots of the same pigment grade. Wa
8、ter-soluble salts also affect the water resistance and blister resis-tance of coatings, especially primers for steel. Conductivitymeasurements, however, cannot be used as the only method todetermine and compare the amount of water soluble salts ofpigments with the same chemical composition but produ
9、ced bydifferent manufacturing processes.5. Apparatus5.1 Centrifuge (optional), having a 500-mL capacity percup.5.2 Filter Paper (Note 1)For high reliability avoid use offilter paper containing soluble material. Each filter should bewashed with reagent water in the funnel until resistance of thefiltr
10、ate is greater than 200 000 cm.NOTE 1The size of the filter paper will be determined by howvoluminous the pigment is. Some organic pigments require at least a185-mm paper for proper filtering.5.3 Filter Aid (optional)The use of a filter aid may bedesirable with some pigments to improve filtration. H
11、owever,the filter aid must be treated to meet the same specifications forfilter paper as given in 5.2.5.4 Ungraduated Cylinders, approximately 35 mm wide by125 mm deep.5.5 Thermometer, graduated in 0.2C intervals.5.6 Conductivity Bridge.35.7 Conductivity Cell,3having a cell constant, K,of1.Thecell c
12、onstant recommended for various ranges of electrolytes isas follows:5.7.1 For specific resistances of less than 250 cm, use acell with a constant of 10 or more.5.7.2 For specific resistances from 250 to 200 000 cm,use a cell with a constant of 1. This covers the range for mostpigments.1This test met
13、hod is under the jurisdiction of ASTM Committee D01 on Paintand Related Coatings, Materials, and Applications and is the direct responsibility ofSubcommittee D01.31 on Pigment Specifications.Current edition approved Nov. 1, 2012. Published November 2012. Originallyapproved in 1966. Last previous edi
14、tion approved in 2007 as D2448 85 (2007).DOI: 10.1520/D2448-85R12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM web
15、site.3Any commercially produced conductivity bridge and conductivity cell issatisfactory.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15.7.3 For specific resistances of reagent water or of over200 000 cm, use a cell with a constant
16、of 0.1.6. Reagents6.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,where such specifications are available
17、.4Other grades may beused, provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.6.2 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean reagent grade water asdefined
18、by Type II of Specification D1193.6.3 Methanol.6.4 Potassium Chloride, Standard Solution (0.02 N) Pre-pare a 0.02 N potassium chloride (KCl) solution with water bydissolving 1.491 g of KCl (heated before weighing for1hat105C) in water, followed by dilution to 1 L.7. Determination of Cell Constant7.1
19、 Prepare a 0.002 N solution of KCl by diluting the 0.02N KCl solution described in 6.4 with water. Cool and measurethe specific resistance, Rm,at2560.5C as described in 8.2.2.7.2 Calculate the cell constant, K, as follows:K255 Rm/Rs!where:Rm= specific resistance at 25C (see 8.2.2), andRs= specific r
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD244819852012STANDARDTESTMETHODFORWATERSOLUBLESALTSINPIGMENTSBYMEASURINGTHESPECIFICRESISTANCEOFTHELEACHATEOFTHEPIGMENT

链接地址:http://www.mydoc123.com/p-512884.html