ASTM D2444-2017 Standard Practice for Determination of the Impact Resistance of Thermoplastic Pipe and Fittings by Means of a Tup (Falling Weight)《通过Tup(跌落重量)测定热塑性塑料管和配件的抗冲击性的标准实践》.pdf
《ASTM D2444-2017 Standard Practice for Determination of the Impact Resistance of Thermoplastic Pipe and Fittings by Means of a Tup (Falling Weight)《通过Tup(跌落重量)测定热塑性塑料管和配件的抗冲击性的标准实践》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2444-2017 Standard Practice for Determination of the Impact Resistance of Thermoplastic Pipe and Fittings by Means of a Tup (Falling Weight)《通过Tup(跌落重量)测定热塑性塑料管和配件的抗冲击性的标准实践》.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D2444 99 (Reapproved 2010)D2444 17Standard Test Method Practice forDetermination of the Impact Resistance of ThermoplasticPipe and Fittings by Means of a Tup (Falling Weight)1This standard is issued under the fixed designation D2444; the number immediately following the designation indi
2、cates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of
3、 the U.S. Department of Defense.1. Scope1.1 This test method covers the determination of the impact resistance of thermoplastic pipe and fittings under specifiedconditions of impact by means of a tup (falling weight). Three interchangeable striking noses are used on the tup, differing ingeometrical
4、configuration. Two specimen holders are described.1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information only and are not considered standard.1.3 This standard does not purpor
5、t to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D618 Pr
6、actice for Conditioning Plastics for TestingD2122 Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings3. Significance and Use3.1 The impact resistance of thermoplastic pipe and fittings relates to suitability for service and to quality of processing. Impactresistance may also pr
7、ovide a relative measure of a materials resistance to breakage during handling and installation and, fornon-buried applications, to in-service breakage. See Appendix X4 for guidelines for selecting testing combinations.3.2 Results obtained by use of this test method can be used in three ways:3.2.1 A
8、s the basis for establishing impact test requirements in product standards,3.2.2 To measure the effect of changes in materials or processing, and3.2.3 To measure the effect of the environment.4. Apparatus4.1 GeneralOne type of impact tester is illustrated in Fig. 1.4.2 Tup:4.2.1 The tup nose shall b
9、e as shown in Fig. 2. When used with the 0.50-in. (12.7-mm) radius nose, it is designated as Tup A.When used with the 2.00-in. (51-mm) radius nose, it is designated as Tup B. When used with the 0.25-in. (6.3-mm) radius nose,it is designated as Tup C.NOTE 1It is suggested that tups be made of scratch
10、-resistant steel to reduce damage to the nose. Badly scarred noses may affect test results.4.2.2 The mass of the tup shall be 6, 12, 20, or 30 lb (2.7, 5.4, 9.1, or 13.6 kg).4.3 Drop Tube:1 This test method pracitce is under the jurisdiction of ASTM Committee F17 on Plastic Piping Systems and is the
11、 direct responsibility of Subcommittee F17.40 on TestMethods.Current edition approved Aug. 1, 2010Nov. 15, 2017. Published November 2010February 2018. Originally approved in 1965. Last previous edition approved in 20052010as D2444 99(2005).(2010). DOI: 10.1520/D2444-99R10.10.1520/D2444-17.2 For refe
12、rencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide t
13、he user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the stand
14、ard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1FIG. 1 One Type of Tup Impact TesterNOTE 1Dimensions are in inches (millimetres).FIG. 2 Tup Nose DetailD2444 1724.3.1 T
15、he drop tube shall be of sufficient length (approximately 12 ft (3.7 m) to provide for a fall of at least 10 ft (3.0 m) andshall be mounted so that the lengthwise direction is vertical as measured with a plumb bob or a spirit level at least 2 ft (610 mm)in length.4.3.2 Care must be taken to ensure t
16、hat the tup falls freely; it must not “chatter” down the tube.NOTE 2No material for the drop tube is specified. However, a colddrawn seamless steel tubing with an inside diameter of 2.563 6 0.003 in. (65.106 0.08 mm), or acrylonitrile-butadiene-styrene (ABS) or poly(vinyl chloride) (PVC) plastic pip
17、e, 212 in. nominal pipe size, with a standard dimensionratio (SDR) of 21, have been found to be satisfactory.NOTE 3Provided equivalent results are obtained, the tup may be dropped without a drop tube or guided by other means. The drop tube is used toreduce the hazard to operators and property that m
18、ay occur when the tup rebounds. It also helps guide and center the tup so that it will be more likelyto strike the top of the test specimen. It may also be necessary to provide a protective barrier around the specimen, particularly for larger sizes of pipeand fittings, to protect the operator from f
19、lying broken pieces.NOTE 4The tup may not fall freely if the clearance between the tup and tube is too large or too small, or if it is restrained by a partial vacuum abovethe tup, such as can be caused by the hold and release device.4.3.3 Means shall be provided (1) to hold the tup at steps of 2 in.
20、 (50.8 mm) for a distance of 2 to 10 ft (610 mm to 3.0 m)above the specimen holder, (2) to release the tup in a reproducible manner, (3) to allow the tup to fall freely, and (4) to catch thetup on the first rebound. Refer to Fig. 1.4.4 Specimen HolderTwo specimen holders are described. The V-block (
21、HolderA) is usually used with TupsAand C; the flatplate (Holder B) is often used with Tup B or for testing fittings.4.4.1 The V-block holder shall be at least as long as the specimen being tested and shall have a 90-deg included angle. It maybe fabricated or of solid construction. The side supports
22、shall be of sufficient depth to support the specimen in the V and not onthe top edges of the V-block.NOTE 5Both aluminum and steel have been found suitable for the holders.4.4.2 The flat-plate holder shall consist of a plate approximately 8 by 12 by 1 in. (203 by 305 by 25.4 mm) in which a grooveto
23、position the pipe specimen shall be cut. This groove shall be about 0.12 in. (3 mm) in depth with the edges rounded to a radiusof about 0.06 in. (1.5 mm). Fittings that do not contact the plate directly under the point of impact shall be supported at this pointby a flat steel plate or shim. The spec
24、imen holder shall be mounted on a rigid base fastened to a concrete slab. Means shall beprovided to center the specimens under the drop tube. A bar or rod placed inside the specimen and retained by a light spring maybe employed if difficulty is encountered in holding the specimen in position.5. Test
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD24442017STANDARDPRACTICEFORDETERMINATIONOFTHEIMPACTRESISTANCEOFTHERMOPLASTICPIPEANDFITTINGSBYMEANSOFATUPFALLINGWEIGHT

链接地址:http://www.mydoc123.com/p-512882.html