ASTM D2332-2013 Standard Practice for Analysis of Water-Formed Deposits by Wavelength-Dispersive X-Ray Fluorescence《用波长色散X射线荧光法作水沉积物分析标准操作规程》.pdf
《ASTM D2332-2013 Standard Practice for Analysis of Water-Formed Deposits by Wavelength-Dispersive X-Ray Fluorescence《用波长色散X射线荧光法作水沉积物分析标准操作规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2332-2013 Standard Practice for Analysis of Water-Formed Deposits by Wavelength-Dispersive X-Ray Fluorescence《用波长色散X射线荧光法作水沉积物分析标准操作规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D2332 13Standard Practice forAnalysis of Water-Formed Deposits by Wavelength-Dispersive X-Ray Fluorescence1This standard is issued under the fixed designation D2332; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers X-ray spectrochemical analysis ofwater-formed deposits.1.2 The practice is applicable to
3、the determination ofelements of atomic number 11 or higher that are present insignificant quantity in the sample (usually above 0.1 %).1.3 The values stated in SI units are to be regarded asstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its
4、use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D887 Practices for Sampling Water-Formed DepositsD1129 Terminology Relati
5、ng to WaterD1193 Specification for Reagent WaterE11 Specification for Woven Wire Test Sieve Cloth and TestSieves3. Terminology3.1 For definitions of terms used in this practice, refer toTerminology D1129.4. Summary of Practice4.1 The sample or its fusion with a suitable flux is powderedand the powde
6、r is compacted (mounted). The mount is thenirradiated by an X-ray beam of short wavelength (high energy).The characteristic X rays of the atom that are emitted orfluoresced upon absorption of the primary or incident X raysare dispersed, and intensities at selected wavelengths aremeasured by sensitiv
7、e detectors. Detector output is related toconcentration by calibration curves or charts.4.2 The K spectral lines are used for elements of atomicnumbers 11 to 50. Whether the K or L lines are used for theelements numbered 51 or higher depends on the availableinstrumentation.5. Significance and Use5.1
8、 Certain elements present in water-formed deposits areidentified. Concentration levels of the elements are estimated.5.2 Deposit analysis assists in providing proper water con-ditioning.5.3 Deposits formed from or by water in all its phases maybe further classified as scale, sludge, corrosion produc
9、ts, orbiological deposits. The overall composition of a deposit orsome part of a deposit may be determined by chemical orspectrographic analysis; the constituents actually present aschemical substances may be identified by microscope or X-raydiffraction studies. Organisms may be identified by micro-
10、scopical or biological methods.6. Apparatus6.1 Sample Preparation Equipment:6.1.1 Fusion Crucibles, prepared from 25-mm (1-in.)commercial-grade graphite rods. The dimensions shall be 29mm (118 in.) high, an inside diameter of 19 mm (34 in.), and acavity 22 mm (78 in.) deep.6.1.2 Pulverizers, includi
11、ng an agate or mullite mortar andpestle, minimum capacity 25 ml.6.1.3 SievesNo. 100 (150-m) and No. 270 (53-m) asspecified in Specification E11.6.1.4 CompactorsA press, equipped with a gauge en-abling reproducible pressure, is recommended.6.2 Excitation Source (X-ray Tube):6.2.1 Stable Electrical Po
12、wer Supply (61 %).6.2.2 Source of high-intensity, short-wave-length X rays.6.3 Sample Housing (Turret).1This practice is under the jurisdiction of ASTM Committee D19 on Water andis the direct responsibility of Subcommittee D19.03 on Sampling Water andWater-Formed Deposits, Analysis of Water for Powe
13、r Generation and Process Use,On-Line Water Analysis, and Surveillance of Water.Current edition approved Jan. 1, 2013. Published February 2013. Originallyapproved in 1965. Last previous edition approved in 2008 as D2332 08. DOI:10.1520/D2332-13.2For referenced ASTM standards, visit the ASTM website,
14、www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States16.4
15、 SpectrometerBest resolution of the spectrometer andbest sensitivity are not simultaneously attainable; a compro-mise is effected to give adequate values for each.6.4.1 Collimating System.6.4.2 Spectrogoniometer.6.4.3 Analyzing Crystal and HolderThe choice of theanalyzing crystal is made on the basi
16、s of what elements mustbe determined; for example, a gypsum or an ammoniumdihydrogen phosphate crystal can be used for determiningmagnesium but lithium fluoride is much superior for copperand iron (high-intensity diffracted secondary rays and conse-quently greater sensitivity and potential precision
17、). A salt,sodium chloride (NaCl), crystal is frequently employed forgeneral use, being applicable over a broad range and producingintense lines and medium broadening.6.4.4 Counter-Tube Support.6.5 Evacuating or Flushing System.6.6 Measuring System:6.6.1 Detector (of which the principal types are the
18、 Geigercounter, scintillation counter, and flow-proportional counter).6.6.2 Amplifiers (Including Preamplifier), Rate Meter,Recorder, Scaler, and Printout.6.6.3 Zeroing, Gain, and Sequence Controls.7. Reagents7.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise i
19、ndicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,where such specifications are available.3Other grades may beused, provided it is first ascertained that the reagent is ofsufficiently high purity to
20、 permit its use without lessening theaccuracy of the determination.7.2 Purity of WaterReference to water that is used forreagent preparation, rinsing or dilution shall be understood tomean water that conforms to the quantitative specifications ofType I or II reagent water of Specification D1193.7.3
21、Detector Gas, usual composition 90 % argon, 10 %methane (other compositions are used); usually used withflow-proportional counter for lines of longer wavelength (0.2nm or greater).7.4 Gallium Oxide, spectrographic grade (frequently used asa convenient internal standard).7.5 Helium Gas, commercial gr
22、ade, for the spectrometerflushing system, when vacuum or air paths are not used.7.6 Sodium and Lithium Borates(Na2B4O7and Li2B4O7),commonly used as fluxes for the sample.8. Sampling8.1 Collect the sample in accordance with Practices D887.9. Preparation of Sample9.1 Reduce the entire sample of deposi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD23322013STANDARDPRACTICEFORANALYSISOFWATERFORMEDDEPOSITSBYWAVELENGTHDISPERSIVEXRAYFLUORESCENCE 波长

链接地址:http://www.mydoc123.com/p-512694.html