ASTM D938-2005 Standard Test Method for Congealing Point of Petroleum Waxes Including Petrolatum《包括凡士林在内的石油蜡凝固点的标准试验方法》.pdf
《ASTM D938-2005 Standard Test Method for Congealing Point of Petroleum Waxes Including Petrolatum《包括凡士林在内的石油蜡凝固点的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D938-2005 Standard Test Method for Congealing Point of Petroleum Waxes Including Petrolatum《包括凡士林在内的石油蜡凝固点的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 938 05Designation: 76/70(95)An American National StandardBritish Standard 5088Standard Test Method forCongealing Point of Petroleum Waxes, IncludingPetrolatum1This standard is issued under the fixed designation D 938; the number immediately following the designation indicates the year
2、 oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Departme
3、nt of Defense.1. Scope*1.1 This test method covers determination of the congealingpoint of petroleum waxes, including petrolatum.1.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.3 This standard does not purport to address
4、all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 1This test method is an alternative to Test Method D 127
5、.Results obtained are usually lower than the results obtained by TestMethod D 127 IP 133, the amount of the deviation varying with thenature of the petroleum wax.2. Referenced Documents2.1 ASTM Standards:2D 127 Test Method for Drop Melting Point of PetroleumWax, Including PetrolatumE1 Specification
6、for ASTM Liquid-in-Glass Thermometers3. Terminology3.1 Definitions:3.1.1 congealing point, nof petroleum wax, that tempera-ture at which molten petroleum wax, when allowed to coolunder prescribed conditions, ceases to flow.4. Summary of Test Method4.1 A sample of wax is melted and a droplet is made
7、toadhere to the bulb of a thermometer. Using a prewarmed flaskas an air jacket, the droplet on the bulb is allowed to cool at afixed rate until it congeals. The congealing point is observed asthe temperature at which the droplet ceases to flow as thethermometer is turned.5. Significance and Use5.1 C
8、ongealing point is a wax property that is of interest tomany petroleum wax consumers. The procedure described heremeasures the temperature at which a sample being cooleddevelops a “set” or resistance to flow. At that temperature, thewax may be at or close to the solid state, or it may be semisolidan
9、d quite unctuous, depending on the composition of the waxor petrolatum being tested. In the case of petrolatums, congeal-ing property is associated with the formation of a gel structureas the sample cools.6. Apparatus6.1 Thermometer, having the following range and conform-ing to the requirements pre
10、scribed in Specification E1or in thespecifications for IP Standard Thermometers:Thermometer NumberTemperature Range ASTM IP20 to 100C 54C 18C68 to 213F 54F 18F6.2 Erlenmeyer Flask, 125-mL, glass, to serve as a ther-mometer jacket.6.3 Cork or Rubber Stopper, for attaching the thermometerto the Erlenm
11、eyer flask.7. Procedure7.1 Adjust the thermometer through the stopper so that thebottom of the bulb will be 10 to 15 mm above the bottom of theErlenmeyer flask when the stopper is fitted snugly in the flask.After making this adjustment, remove the thermometer andstopper from the flask, being careful
12、 not to change the positionof the stopper relative to the thermometer stem.7.2 Place approximately 50 g of sample, which is represen-tative of the material under inspection, in a porcelain evapo-rating dish or other suitable container.1This test method is under the jurisdiction of ASTM Committee D02
13、 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.10 on Properties of Petroleum Wax.Current edition approved Nov. 1, 2005. Published November 2005. Originallyapproved in 1947. Last previous edition approved in 2004 as D 93804.2For referenced ASTM standards, vis
14、it the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International,
15、 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.7.3 Place the empty Erlenmeyer flask (without the ther-mometer assembly) and the container holding the specimen ina temperature-controlled oven set at 99 6 3C (210 6 5F)until the specimen and the flask reach oven te
16、mperature.NOTE 2For nonreferee, routine testing of samples known to have lowcongealing points, the oven may be set at a lower temperature, but it mustbe at least 11C (20F) above the expected congealing point of the sample.7.4 Remove the specimen from the oven and completelyimmerse the thermometer bu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD9382005STANDARDTESTMETHODFORCONGEALINGPOINTOFPETROLEUMWAXESINCLUDINGPETROLATUM 包括 凡士林 在内 石油 凝固点

链接地址:http://www.mydoc123.com/p-512551.html