ASTM D906-1998(2011) Standard Test Method for Strength Properties of Adhesives in Plywood Type Construction in Shear by Tension Loading《拉力负荷法测定胶合板结构中胶粘剂抗剪切强度特性的标准试验方法》.pdf
《ASTM D906-1998(2011) Standard Test Method for Strength Properties of Adhesives in Plywood Type Construction in Shear by Tension Loading《拉力负荷法测定胶合板结构中胶粘剂抗剪切强度特性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D906-1998(2011) Standard Test Method for Strength Properties of Adhesives in Plywood Type Construction in Shear by Tension Loading《拉力负荷法测定胶合板结构中胶粘剂抗剪切强度特性的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D906 98 (Reapproved 2011)Standard Test Method forStrength Properties of Adhesives in Plywood TypeConstruction in Shear by Tension Loading1This standard is issued under the fixed designation D906; the number immediately following the designation indicates the year oforiginal adoption or,
2、 in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.INTRODUCTIO
3、NThe accuracy of the results of strength tests of adhesive bonds will depend on the conditions underwhich the bonding process is carried out. Unless otherwise agreed upon between the manufacturer andthe purchaser, the bonding conditions shall be prescribed by the manufacturer of the adhesive. In ord
4、erto ensure that complete information is available to the individual conducting the tests, themanufacturer of the adhesive shall furnish numerical values and other specific information for each ofthe following variables:(1) The moisture content of the wood at the time of bonding.(2) Complete mixing
5、directions for the adhesive.(3) Conditions for application of the adhesive including the rate of spread or thickness of film,number of coats to be applied, whether more than one coat is required.(4) Assembly conditions before application of pressure, including the room temperature, length oftime, an
6、d whether open or closed assembly is to be used.(5) Curing conditions, including the amount of pressure to be applied, the length of time underpressure and the temperature of the assembly when under pressure. It should be stated whether thistemperature is that of the bond line, or of the atmosphere
7、at which the assembly is to be maintained.(6) Conditioning procedure before testing, unless a standard procedure is specified, including thelength of time, temperature, and relative humidity.Arange may be prescribed for any variable by the manufacturer of the adhesive if it can be assumedby the test
8、 operator that any arbitrarily chosen value within such a range or any combination of suchvalues for several variables will be acceptable to both the manufacturer and the purchaser of theadhesive.1. Scope1.1 This test method covers the determination of the com-parative shear strengths of adhesives i
9、n plywood-type con-struction, when tested on a standard specimen and underspecified conditions of preparation, conditioning, and testing.This test method is intended to be applied only to adhesivesused in bonding wood to wood.1.2 The values stated in SI units are to be regarded as thestandard. The v
10、alues given in parentheses are provided forinformation purposes only.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the
11、applica-bility of regulatory limitations prior to use.1This test method is under the jurisdiction of ASTM Committee D14 onAdhesives and is the direct responsibility of Subcommittee D14.30 on WoodAdhesives.Current edition approved April 1, 2011. Published April 2011. Originallyapproved in 1947. Last
12、previous edition approved in 2004 as D906 98 (2004).DOI: 10.1520/D0906-98R11.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.2. Referenced Documents2.1 ASTM Standards:2D143 Test Methods for Small Clear Specimens of TimberD907 Termino
13、logy of Adhesives3. Terminology3.1 DefinitionsMany terms in this test method are definedin Terminology D907.3.1.1 plywood, na panel generally flat built up of layers ofveneer called plies, united under pressure by an adhesive tocreate a panel with the bond between the plies as strong as, orstronger
14、than, the wood, and that has the following character-istics: (1) is constructed of an odd number of layers with grainof adjacent layers perpendicular, (2) with a layer consisting ofeither a single ply or two or more plies laminated with parallelgrain direction, and (3) with outer layers and all odd
15、numberedlayers generally having the grain direction oriented parallel tothe long dimension of the panel.3.1.1.1 DiscussionGenerally, the grain of one or moreplies is approximately at right angles to the other plies, andalmost always an odd number of plies are used.3.1.2 shear, nin an adhesively bond
16、ed joint, stress, strainor failure resulting from applied forces that tend to causeadjacent planes of a body to slide parallel in opposite direc-tions.4. Significance and Use4.1 The way adhesives are used in plywood makes shearstrength an important performance criteria.4.2 Shear strength measured by
17、 this test is suitable for use inadhesive development, manufacturing quality control, and inmaterials performance specifications.5. Apparatus5.1 The testing machine shall be adjusted to a loading rateof between 4535 and 7560 g/s (600 and 1000 lb/min). Wherethe testing machine is adjusted by rate of
18、crosshead movementrather than load application rate, an appropriate head move-ment rate shall be selected so as to yield an average loadapplication rate in the 4535 to 7560 g/s (600 to 1000 lb/min)range. It shall be provided with suitable grips and jaws so thatthe specimen can be gripped tightly and
19、 held in alignment asthe load is applied. The grips and jaws shown in Fig. 1 havebeen found satisfactory. The testing machine shall be located inan atmosphere such that the moisture content of the specimensdeveloped under the conditions prescribed in Section 8 is notnoticeably altered during testing
20、.6. Test Specimens6.1 The test specimens shall conform to the form anddimensions shown in Fig. 2. The specimens shall be cut fromtest panels prepared as described in Sections 7 and 8.6.2 At least 40 specimens, representing at least five differentpanels, shall be prepared, selected and tested as pres
21、cribed inSections 9 and 10.7. Preparation and Test Panels7.1 The standard substrate for this test method is 1.6mm(1/16in.) thick rotary-cut or sliced veneer of sweet birch(Betula lenta) or yellow birch (Betula alleghaniensis). Anyother thickness or species of veneer may be substituted uponwritten ag
22、reement between the party requesting this test andthe manufacturer of the adhesive. Select veneer that is free ofdefects such as knots or distorted grain around knots, cracks,short grain (fibers out of plane), rough surfaces, or unusualdiscoloration that would indicate decay. Do not sand theveneer.7
23、.2 Cut the selected veneer into a size suitable for pressingand for cutting specimens with minimal waste. Allow at least12-in. (13 mm) for trim around the edges.NOTE 1When cutting the veneer to size, ensure that the fiber directionis parallel and perpendicular to the edges. Appearances may be decept
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD90619982011STANDARDTESTMETHODFORSTRENGTHPROPERTIESOFADHESIVESINPLYWOODTYPECONSTRUCTIONINSHEARBYTENSIONLOADING

链接地址:http://www.mydoc123.com/p-512458.html